BMC
T
IME
S
YNC
4-4
Time Sync
In S2TS/TQ BMC design, BMC does not have a local RTC to
know what time it is. Each time the server powers on, BIOS will
use Set SEL Time command to initialize BMC time. The remote
console program interpret this time as pre-initial.
SEL
BMC supports IPMI 1.5/2.0 standard SEL operation. It can keep
to maximum 909 entries SEL log. Event happened in BIOS side
will be logged by using Add SEL Entry command. BMC will
store them in FLASH, the time stamp field will be filled by BMC.
When SEL is full, the new SEL won’t be logged but will go
through PEF as usual. If AC powers off, all SELs will remain in
NV.
Platform Event
Platform Event Filter
The BMC implements selectable action on an event or LAN
alerting base on event. By default, no any PEF entries or
actions exist, applications need to configure it to enable.
The number of Platform Event Filter Table is 40.
The number of Alert Policy Table is 120 and Alert Destina-
tion Table is 30.
Dedicated and Shared NIC)
The policy to match an event to Platform Event Filter Table
entry is IPMI 1.5 standard.
The action support Power Off, Power Reset, Power Cycle
and NMI.
All Platform Event Filter Table is default disabled.
PEF Startup Delay and Last Processed Event tracking is
not supported.
PEF table lookup isn’t correlated to log SEL to SEL
Repository.
Serial Alerting is no support.
Содержание STRATOS S200 Series S200-X12TS
Страница 24: ...About the Server Chapter 1 ...
Страница 50: ...Installing Hardware Chapter 2 ...
Страница 95: ...BIOS Chapter 3 ...
Страница 150: ...BMC Chapter 4 ...
Страница 215: ...Connectors and Jumpers Chapter 5 ...
Страница 218: ...Rail Kit Assembly Chapter 6 ...
Страница 222: ...Troubleshooting Chapter 7 ...
Страница 228: ...Installation and Assembly Safety Instructions Chapter 8 ...
Страница 232: ...Safety Information Chapter 9 ...
Страница 241: ...Regulatory and Compliance Infor mation Chapter 10 ...