WALK TESTING PROCEDURE
The sensor will rotate from left to right. Adjust the sensor to point in the desired direction.
See diagram A & H for the different sensor patterns and lens masking.
See diagram C & I for the adjustment controls. Set the Time,Dusk and Dim control as follows :
TIME - Fully anti-clockwise
DUSK - Fully clockwise
Dim - Fully anti clockwise
The unit will now operate during daytime as well as at night, illuminating the lamp for approx.
5 seconds each time. This allows testing to be carried out to establish the best position for the
sensor.
Switch on the mains power. The lamp will immediately illuminate as the unit goes through its
"warm-up" period. After approximately 1 - 2 minutes the lamp will extinguish. Try to remain
outside the detection area during the warm-up period.
Walk across the detection area approx 5 metres from the unit. As you cross a detection "zone"
the lamp will illuminate. Now stand still until the lamp extinguishes (this should take approx. 5
seconds).
Start moving again. As you cross each "zone" the lamp will illuminate.
Repeat the above, walking at various distances and angles to the unit. This will help you to
establish the detection pattern.