OPERATION AND TESTING

WALK TESTING PROCEDURE

The sensor will rotate from left to right. Adjust the sensor to point in the desired direction.

See diagram A & H for the different sensor patterns and lens masking.

See diagram C & I for the adjustment controls. Set the Time,Dusk and Dim control as follows :                   

 

 

 

TIME - Fully anti-clockwise 

 

 

                    DUSK - Fully clockwise 

 

 

 

Dim - Fully anti clockwise

The unit will now operate during daytime as well as at night, illuminating the lamp for approx. 
5 seconds each time. This allows testing to be carried out to establish the best position for the 
sensor.

Switch on the mains power.  The lamp will immediately illuminate as the unit goes through its 
"warm-up" period. After approximately 1 - 2 minutes the lamp will extinguish. Try to remain 
outside the detection area during the warm-up period. 

Walk across the detection area approx 5 metres from the unit. As you cross a detection "zone" 
the lamp will illuminate. Now stand still until the lamp extinguishes (this should take approx. 5 
seconds).

Start moving again. As you cross each "zone" the lamp will illuminate.

Repeat the above, walking at various distances and angles to the unit. This will help you to 
establish the detection pattern.
 

Содержание 230W Security Floodlight

Страница 1: ...IQ NALP 180 300 D GR V4 0 10 11 I N S T A L L E R G U I D E 230W Security Floodlight QUANTA...

Страница 2: ...nt Do not attempt to install during wet weather if you are suffering from nausea or dizzy spells or on medication with similar side effects If in any doubt consult a qualified tradesperson or electric...

Страница 3: ...in the lampholder before use Re attach the clip to secure the glass shield to the floodlight Remove the wall plate from the unit by inserting a terminal screwdriver into the slot at the top See diagr...

Страница 4: ...is allows testing to be carried out to establish the best position for the sensor Switch on the mains power The lamp will immediately illuminate as the unit goes through its warm up period After appro...

Страница 5: ...Less sensitive More sensitive TOP VIEW SIDE VIEW 12m 2 5m A C B D LUX TIME TIMER DIM 180 Degrees...

Страница 6: ...INSTALLATION DIAGRAM E...

Страница 7: ...Wall Plate Cable Entry Blue Green Yellow Brown N E L Match the three pins on the unit to the wall plate Connect the mains cable to N E L connections in the terminal block CONNECTION DIAGRAM F...

Страница 8: ...a in that section of the sensor CAUTION IF THE PROTECTIVE GLASS SHIELD FOR THE LIGHT IS DAMAGED OR CRACKED IT MUST BE REPLACED IMMEDIATELY 8 8 8 8 Engraving indicates the approx detection range of eac...

Страница 9: ...l a point is reached where the lamp illuminates Leave the control set at this point DIMMER Hi Lo CONTROL The DIMMER setting controls the courtesy light option The DIMMER is adjustable from 0 OFF to 50...

Страница 10: ...become operative at approximately the same level of darkness each evening Observe the operation of the unit If the unit is starting to operate too early ie when it is quite light adjust the control sl...

Страница 11: ...ow it to cool about 5 minutes before touching it 2 Replacement bulb type is 240V mains halogen Max 300W R7S cap floodlight bulb 3 Isolate the mains supply and then unfasten the glass cover 4 Open the...

Страница 12: ...ent to your property Check that the power is switched ON at the circuit breaker internal wall switch Turn OFF the power to the unit and check the wiring connections as per the diagram see previous sec...