QUANTA 230W Security Floodlight Скачать руководство пользователя страница 2

SECTION ONE

GENERAL INFORMATION

The unit utilises passive infrared technology to detect heat radiation of moving human bodies. 
Upon detection, the lamp will illuminate for a user-determined time period. An integral daylight 
sensor ensures night-only operation. This unit has a dual light level operation. During darkness 
the lamp will illuminate constantly at a user defined light level until it detects movement, then the 
unit will switch to full brightness for a user defined time on period.

PARTS INCLUDED 

- Luminaire PIR Sensor unit.
- Instruction manual. Please keep safe for future reference.
- Accessory Pack.
- Tungsten halogen bulb

TOOLS & PARTS NEEDED 

- 3 core flexible rubber cable (1.0mm² or 1.5mm² "H05RN-F")
- Electric/hand-held drill & bits.
- Terminal or Electrician’s screwdriver
- Large slotted/philips screwdriver
- Wire cutters

Unit is for outdoor use only.  Unit must be mounted on a non-flammable surface as a fixed 
luminaire, and is not suitable for portable use.
The unit can get very hot during use.  Ensure the unit has cooled before handling.
Ensure adequate ventilation space is allowed between the unit and any object above, in front or 
to either side of the unit. Suggested space is 0.5m above, 0.3m to either side & 1.0m in front.
Do not attempt to install during wet weather, if you are suffering from nausea or dizzy spells or on 
medication with similar side effects.
If in any doubt, consult a qualified tradesperson or electrician.

SECTION TWO

SELECTING THE LOCATION

The motion detector has a number of detection zones, at various vertical and horizontal angles 
as shown (see diagram A). 
A moving human body needs to cross/enter one of these zones to activate the sensor. The best 
all-round coverage is achieved with the unit mounted at the optimum height of 2.5m. 
 
Careful positioning of the sensor will be required to ensure optimum performance. See diagram A 
detailing detection range and direction.

The sensor is more sensitive to movement ACROSS its field of vision than to movement directly 
TOWARDS (see diagram B). Therefore position the unit so that the sensor looks ACROSS the 
likely approach path.
Avoid positioning the sensor where there are any sources of heat in the detection area (extractor 
fans, tumble dryer exhausts etc.) including any other light sources such as other security lighting. 
Reflective surfaces (ie pools of water or white-painted walls) and overhanging branches may 
cause false activation under extreme conditions.
 
During extreme weather conditions the motion sensor may exhibit unusual behaviour. This 
does not indicate a fault with the sensor. Once normal weather conditions return, the sensor will 
resume normal operation. 

Содержание 230W Security Floodlight

Страница 1: ...IQ NALP 180 300 D GR V4 0 10 11 I N S T A L L E R G U I D E 230W Security Floodlight QUANTA...

Страница 2: ...nt Do not attempt to install during wet weather if you are suffering from nausea or dizzy spells or on medication with similar side effects If in any doubt consult a qualified tradesperson or electric...

Страница 3: ...in the lampholder before use Re attach the clip to secure the glass shield to the floodlight Remove the wall plate from the unit by inserting a terminal screwdriver into the slot at the top See diagr...

Страница 4: ...is allows testing to be carried out to establish the best position for the sensor Switch on the mains power The lamp will immediately illuminate as the unit goes through its warm up period After appro...

Страница 5: ...Less sensitive More sensitive TOP VIEW SIDE VIEW 12m 2 5m A C B D LUX TIME TIMER DIM 180 Degrees...

Страница 6: ...INSTALLATION DIAGRAM E...

Страница 7: ...Wall Plate Cable Entry Blue Green Yellow Brown N E L Match the three pins on the unit to the wall plate Connect the mains cable to N E L connections in the terminal block CONNECTION DIAGRAM F...

Страница 8: ...a in that section of the sensor CAUTION IF THE PROTECTIVE GLASS SHIELD FOR THE LIGHT IS DAMAGED OR CRACKED IT MUST BE REPLACED IMMEDIATELY 8 8 8 8 Engraving indicates the approx detection range of eac...

Страница 9: ...l a point is reached where the lamp illuminates Leave the control set at this point DIMMER Hi Lo CONTROL The DIMMER setting controls the courtesy light option The DIMMER is adjustable from 0 OFF to 50...

Страница 10: ...become operative at approximately the same level of darkness each evening Observe the operation of the unit If the unit is starting to operate too early ie when it is quite light adjust the control sl...

Страница 11: ...ow it to cool about 5 minutes before touching it 2 Replacement bulb type is 240V mains halogen Max 300W R7S cap floodlight bulb 3 Isolate the mains supply and then unfasten the glass cover 4 Open the...

Страница 12: ...ent to your property Check that the power is switched ON at the circuit breaker internal wall switch Turn OFF the power to the unit and check the wiring connections as per the diagram see previous sec...

Отзывы: