SECTION SIX

TROUBLESHOOTING GUIDE

PROBLEM

o

 Lamp stays ON all the time at

night.

o

 PIR keeps activating for no 

reason / at random.

o

 PIR sensor will not operate 

at all.

o

 The PIR sensor will not 

operate at night.

o

 Unit activates during the 

daytime

o

 PIR coverage is poor/sporadic

Detection range varies from 

day to day
 

SOLUTION

The unit may be suffering from false activation. Cover the 
sensor lens completely with a thick cloth. This will prevent 
the sensor from "seeing" anything. If the unit now switches 
off after the set time duration and does not re-activate, this 
indicates that the problem was caused by false activation. 
The problem may be solved by slightly adjusting the direction/
angle of the sensor head (see previous section).
You may not be allowing the unit time to complete it's 
warm-up period. Stand well out of the detection range and 
wait (the warm-up period should never exceed 5 minutes).
Occasionally, winds may activate the sensor. Sometimes 
passages between buildings etc. can cause a "wind tunnel" 
effect.
Ensure the unit is not positioned so as to allow detection 
of cars/people using public thoroughfares adjacent to your 
property.

Check that the power is switched ON at the circuit breaker/
internal wall switch.

Turn OFF the power to the unit and check the wiring 
connections as per the diagram (see previous section 3). 
Ensure no connections are loose.
Check the lamp. If the lamp has failed, replace. Ensure that 
the lamp is seated correctly in the lampholder.

The level of ambient light in the area may be too bright to 
allow operation at the current DUSK setting. During the 
hours of darkness, adjust the DUSK control slowly clockwise 
until the lamp illuminates. Refer to previous section for more 
details.

The level of ambient light in the area may be too dark for 
the current DUSK setting. During daylight, adjust the DUSK 
control slightly anti-clockwise. When the lamp extinguishes, 
enter the detection area. If the PIR still activates, the setting 
is still too high. Repeat the above procedure until the PIR 
does not activate when you enter the detection area. Refer to 
previous section for more details.

Unit may be poorly located. See previous section - ‘Selecting 
The Location’ and re-locate the unit.

PIR sensors are influenced by climatic conditions. The colder 
the ambient temperature, the more effective the sensor will 
be. You may need to make seasonal adjustments to the 
sensor head position to ensure trouble-free operation all year 
round.

Содержание 230W Security Floodlight

Страница 1: ...IQ NALP 180 300 D GR V4 0 10 11 I N S T A L L E R G U I D E 230W Security Floodlight QUANTA...

Страница 2: ...nt Do not attempt to install during wet weather if you are suffering from nausea or dizzy spells or on medication with similar side effects If in any doubt consult a qualified tradesperson or electric...

Страница 3: ...in the lampholder before use Re attach the clip to secure the glass shield to the floodlight Remove the wall plate from the unit by inserting a terminal screwdriver into the slot at the top See diagr...

Страница 4: ...is allows testing to be carried out to establish the best position for the sensor Switch on the mains power The lamp will immediately illuminate as the unit goes through its warm up period After appro...

Страница 5: ...Less sensitive More sensitive TOP VIEW SIDE VIEW 12m 2 5m A C B D LUX TIME TIMER DIM 180 Degrees...

Страница 6: ...INSTALLATION DIAGRAM E...

Страница 7: ...Wall Plate Cable Entry Blue Green Yellow Brown N E L Match the three pins on the unit to the wall plate Connect the mains cable to N E L connections in the terminal block CONNECTION DIAGRAM F...

Страница 8: ...a in that section of the sensor CAUTION IF THE PROTECTIVE GLASS SHIELD FOR THE LIGHT IS DAMAGED OR CRACKED IT MUST BE REPLACED IMMEDIATELY 8 8 8 8 Engraving indicates the approx detection range of eac...

Страница 9: ...l a point is reached where the lamp illuminates Leave the control set at this point DIMMER Hi Lo CONTROL The DIMMER setting controls the courtesy light option The DIMMER is adjustable from 0 OFF to 50...

Страница 10: ...become operative at approximately the same level of darkness each evening Observe the operation of the unit If the unit is starting to operate too early ie when it is quite light adjust the control sl...

Страница 11: ...ow it to cool about 5 minutes before touching it 2 Replacement bulb type is 240V mains halogen Max 300W R7S cap floodlight bulb 3 Isolate the mains supply and then unfasten the glass cover 4 Open the...

Страница 12: ...ent to your property Check that the power is switched ON at the circuit breaker internal wall switch Turn OFF the power to the unit and check the wiring connections as per the diagram see previous sec...

Отзывы: