background image

soap is strongly recommended.

* Wear disposable rubber gloves when handling wastewater-contaminated items or chlorine tablets.

* Always dispose of scum, rags, trash, debris, or soiled material in a proper waste container.

* If a wastewater spill or leak occurs in a yard, flush area with plenty of clean water and disinfect. If a spill 

or leak occurs in the house, clean with a dilute solution of bleach.

* Protect any injury, wound, open cut, etc. from exposure to wastewater. 

* If an illness or disease is suspected of coming from exposure to sewage, get proper medical attention 

immediately. 

* Report all accidents relating to sewage exposure to the proper supervisory personnel. 

Follow these safety precautions when performing any excavation or construction work:

* Follow all construction safety procedures during installation.

* Follow electrical safety procedures during installation.

* Fill all holes and depressions in and around the installation area; remove and dispose of all debris from 

installation.

TECHNICAL DATA/DRAWINGS INDEX
ATS-SCAT-8-AC-C500 

 

 8  PDS-ED-1.5 

   16

ATS-SCAT-86-AC-C750 

 

 8  PDS-GT-1.5 

   16

ATS-SCAT-88-AC-C1000 

10 

 9  AC-FT-3    17

ATS-SCAT-886-AC-C1250 

 9  AC-JSB-4 

   17

ATS-SCAT-888-AC-C1500 

 10 

 AC-CP-S-C-T 

   18

ATS-SCAT-8-BC-C500 

 

 10 

 ATS-GRD-100/80/20 

 18

ATS-SCAT-86-BC-C750 

 

 11 

 ATS-GRD-100/80/20-N 

 18

ATS-SCAT-88-BC-C1000    

11 

 

RB-CTA-26x6  

 

19

ATS-SCAT-886-BC-C1250   

12 

 

RB-R-26x18   

 

 

19

ATS-SCAT-888-BC-C1500 

 12 

 RB-L-26    19

ATS-SCAT-6 

  

13

ATS-SCAT-8 

  

13

A300-8” Series Effluent Filter 

14

FPV-H44-4 

  

14

P-SE-13T 

  

15

7

Содержание AeroCell ATS-SCAT-8-AC-C500

Страница 1: ...STWOOD KY 40014 FAX 502 992 8249 www quanics net CLASS I NSF STD 40 WASTEWATER TREATMENT SYSTEM OPERATION MAINTENANCE MANUAL MANUFACTURED PRODUCTS BY QUANICSTM FIXED FILM MEDIA WASTEWATER TREATMENT SY...

Страница 2: ...c Tank 3 Section 2 0 A300 8 Series Effluent Filter 3 Section 3 0 Dosing Tank 4 Section 4 0 Filtered Pump Vault 4 Section 5 0 Controls Pumps Floats 4 Section 6 0 Treatment Module 4 Section 7 0 Recircul...

Страница 3: ...s utilizing fixed film media The module s consist of a fiberglass tank s containing a pre determined amount of media Ef fluent is sprayed over the media utilizing specialized spay nozzles This patente...

Страница 4: ...able float is down the pump will need to be activated manually by switching the HOA switch in the control panel to HAND 6 While the pump is running observe the spray nozzles in the treatment module fo...

Страница 5: ...ed 2 Remove the filter panel Rinse the filter plates with fresh water making sure all septage is rinsed back into the tank The filter plates should be cleaned until all slots are open and free of de b...

Страница 6: ...ocated at the proper level When the ball float is at its lowest position it should be located equal to or just above the on position of the timer enable float figure 1 2 Check that the design recircul...

Страница 7: ...idge has been removed b Check the septic tank to see if it appears normal If not check with the PROPERTY OWNER to determine what inappropriate materials might have been added to the waste stream 3 Rec...

Страница 8: ...ory personnel Follow these safety precautions when performing any excavation or construction work Follow all construction safety procedures during installation Follow electrical safety procedures duri...

Страница 9: ...anics net autocad htm 750 GPD AeroCell System www quanics net autocad htm The septic tank shall have a minimum L W ratio of equal to or greater than one The septic tank shall have a minimum L W ratio...

Страница 10: ...anics net autocad htm 1250 GPD AeroCell System www quanics net autocad htm The septic tank shall have a minimum L W ratio of equal to or greater than one The septic tank shall have a minimum L W ratio...

Страница 11: ...ics net autocad htm The septic tank shall have a minimum L W ratio of equal to or greater than one The septic tank shall have a minimum L W ratio of equal to or greater than one 500 gallons per day 85...

Страница 12: ...W ratio of equal to or greater than one The septic tank shall have a minimum L W ratio of equal to or greater than one 750 gallons per day 138ft3 of Bio COIR media 5 88 gpd ft3 hydraulic loading rate...

Страница 13: ...W ratio of equal to or greater than one The septic tank shall have a minimum L W ratio of equal to or greater than one 1250 gallons per day 223ft3 of Bio COIR media 5 88 gpd ft3 hydraulic loading rate...

Страница 14: ...T 886 BC C1250 1250 12 3 223 5 61 2500 1250 76 8 15 3 81 ATS SCAT 888 AC C1500 ATS SCAT 888 BC C1500 1500 12 3 255 5 88 3000 1500 76 8 15 3 98 The Zabel A300 8x18 VC model effluent filter is used in s...

Страница 15: ...n Outlet hub accepts 4 or 6 SCH 40 outlet pipe All Zabel Filters accept SmartFilter alarm switch GPD Maximum Gallons Per Day FS Filtration Size Warranty for Defects in Material and Workmanship Effluen...

Страница 16: ...3M 300 V SJOW jacketed 2 wire with ground Materials of Construction 300 grade stainless and cast iron Discharge 1 1 2 Warranty for Defects in Material and Workmanship All components 3 Years STEP SYSTE...

Страница 17: ...ears PDS GT 2 0 STEP SYSTEMS Float Tree AC FT 3 Materials Pipe 1 5 or 2 SCH 40 PVC 1 5 or 2 PVC flex tubing True Union Ball Valve PVC Plastic Double block full port design 1 5 or 2 slip slip hubs Fitt...

Страница 18: ...electrical lines HOA Switch for manual pump control mounted on cir cuit board Float Switch Terminal Block Alarm and Control Fuses Programmable Timer with separate variable controls al lows for setting...

Страница 19: ...harge Assembly 2 Years Float Valve Assembly 2 Years ATS GRD 100 80 20 N Materials Risers and Lids High density non corrosive polyethyl ene plastic Stainless steel screws Neoprene gasket IMPORTANT When...

Страница 20: ...19 Wiring Schematics...

Страница 21: ...20 Consecutively Serial Numbered Data Plates Maintenance Sticker...

Страница 22: ...Y OWNER Responsibilities The PROPERTY OWNER confirms that he has read and understands the AeroCell Bio COIR Operation Manual and agrees to operate the QUANICS AeroCell Bio COIR Advanced Treatment Syst...

Страница 23: ...m the date of installation pumps for a period of three years from the date of installation and AeroCell Bio COIR foam for a period of ten years from the date of installation Failed warranted parts sha...

Страница 24: ...X 1520 PHONE 502 992 8200 6244 OLD LAGRANGE ROAD 1 877 QUANICS CRESTWOOD KY 40014 FAX 502 992 8249 www quanics net Treatment system service provider 082707 326 E n g i n e e r i n g Water S o l u t i...

Отзывы: