background image

SPECIFICATIONS

Battery:

3.6 VDC Li/SOCl

2

, non-replaceable, up to 10 years

Storage conditions:

5°C ... 55°C

Water temperature:

0.1°C … 70°C (T70)

Environment:

5°C … 30°C, indoor usage (B, E1)

Sampling frequency:

1 Hz

Wireless M-bus protocol:

Wireless M-Bus (868MHz, C1, format A)

Wireless LoRaWAN:

EU868MHz (SF12 for RX2), 1.0.2-revB, OTAA

LoRaWAN data resolution:

1 hour*

Maximum flow rate (Q

4

):

3 125 l/h

Small leak detection:

>1-9 l/h** over several days (Only using Quandify platform)

Medium leak detection:

>10 l/h for at least 40 min

Large leak detection:

>1500 l/h for at least 5 min

Weight:

280 grams (excluding packaging)

Dimensions:

Width: 40 mm, height: 79 mm, length 87 mm

*More frequent data transmission can be enabled through different subscriptions. Fastest transmission
rate is once every 15 minutes.
**Depending on pipe size & material

Details are subject to change, check the latest version

here

.

Page 10 of 11

The company is not liable for possible errors and/or misprints.

Содержание CubicMeter LTCM02-X

Страница 1: ...ve water meter leakage detector Easy to install water and leak monitor Alerts if water leaks are detected Measures volume to increase awareness One design for multiple pipes No plumber required to ins...

Страница 2: ...Plastic pipes version black 5 Metal pipes version white 5 INSTALLATION GUIDE 6 FUNCTIONAL WATER FLOW TEST 7 ANTI TAMPERING 7 WIRELESS CONNECTION 8 DISPLAY 9 SPECIFICATIONS 10 MAINTENANCE SERVICE 10 De...

Страница 3: ...o improve the system s water flow analysis and predictions The CubicMeter is extremely easy to install and it requires no previous experience to perform Depending on the model It works on pipes betwee...

Страница 4: ...clamps 2x Tamper Seal Covers 2x Tamper Seal Stickers Pipe 15 20 mm Pipe 20 26 mm 1x Remove to activate sticker Model versions LTCM02 P LTCM02 C Plastic pipes model Copper pipes model Details are subj...

Страница 5: ...diameters __ __ Multi layered PEX Aluminum PEX 16 20 or 25 __ __ PEX or PE RT 16 20 or 25 LK Distance pipe 110 plastic spacer Plastic version PEX Aluminium PEX PEX Distance Pipe Metal pipes version wh...

Страница 6: ...g by holding the sticker over the IR eye and releasing when on the correct pipe See full pipe list on previous page Example of Copper 22mm pipe chosen Example of PAL 20mm pipe chosen 5 Verify on the d...

Страница 7: ...you followed the installation and pipe setup instructions correctly You can also try to rotate the device around the pipe in case the pipe has been deformed Note that if the meter has been activated...

Страница 8: ...reate an account on the Quandify portal https portal quandify com and register your device s You will then also be able to integrate the data into your own application using our API https quandify com...

Страница 9: ...code Indicates successful radio transmissions A single dot indicates a faulty radio module Low battery less than 180 days remaining The units perform an LCD check every 5 minutes where all segments ar...

Страница 10: ...5 l h Small leak detection 1 9 l h over several days Only using Quandify platform Medium leak detection 10 l h for at least 40 min Large leak detection 1500 l h for at least 5 min Weight 280 grams exc...

Страница 11: ...ia the meter s built in optical eye or LoRaWAN by authorized personnel If external parts need to be replaced such as pipe clamps and covers only original manufacturer spare parts should be used Replac...

Отзывы: