9 6
Q U A L I T Y F R Y
“SPATULA
ERROR”
The vat or fryer is not correctly
placed in the machine.
Remove the fryer case and put it
back in, making sure you hear a
“click”.
The angled plug is disconnected.
Check the angled plug and motor
connections.
The blade motor turns and still shows
the error.
Contact Technical Support
The blade motor does not turn and
still shows the error.
Contact Technical Support
“SEE
THERMOSTAT”
Elbow plug disconnected.
Check the elbow plug and resistor
connections.
There is not enough oil.
Fill the vat with exactly 5.5 litres
of oil.
The thermostat is disconnected.
Reset the thermostat by pressing
the button located on the right side
of the resistor.
Bad connection between the angled
cable and the resistor.
Check that the black gasket is inside
the heating unit.
Resistor damaged.
Contact Technical Support.
“ERROR
PROBE 1”
The oil level is incorrect.
Fill the vat with exactly 5.5 litres
of oil.
Elbow plug disconnected
Check the elbow plug and resistor
connections.
Bad connection between the angled
cable and the resistor.
Check that the black gasket is inside
the heating unit.
Temperature Probe (S1) faulty.
Contact Technical Support
Resistor damaged.
Contact Technical Support
FIND
IN
G
F
A
UL
TS
A
ND
B
A
SI
C S
O
LU
TI
O
N
S
Содержание iQ 640
Страница 4: ...4 Q U A L I T Y F R Y iQ 640 FES CARROUSEL IMAGE See de iQ 640 FES CARROUSEL OPEN...
Страница 6: ...G e n e r a l i n d e x...
Страница 8: ...8 Q U A L I T Y F R Y IMPORTANT GENERAL INFORMATION...
Страница 51: ...5 1 e n 1 2 3 4 Description of the equipment...
Страница 53: ...5 3 e n 1 3 2 Description of the equipment...
Страница 55: ...5 5 e n 2 7 1 Description of the equipment 3 4 5 6...
Страница 69: ...6 9 e n Product outputs...
Страница 100: ...W W W q u a l i t y f r y c o m M A S A T 0 7 R e v 0 2...
Страница 101: ......
Страница 102: ...w w w q u a l i t y f r y c o m C Albasanz 12 Planta 1 28037 Madrid Spain 34 913 759 567 AUTOMATIC SMART COOKING...