STEP 13)
Connect the plumbing to the valve.
(Follow either (A) Quick-Connect Kit, or (B) Standard
connection instructions below.)
(A)
QUICK-CONNECT KIT INSTALL
If using the optional quick-connect kit/ hoses*,
follow below.
a)
Connect the quick connect hoses to your
plumbing pipes.
b)
Remove the two red clips from the bypass
valve.
c)
Bend the quick connect hose lines from the
plumbing to align with the bypass valve.
d)
Attach the appropriate water lines to
appropriate sides of the bypass valve.
i.
The water supply line connects to the
INLET side of the softener valve.
a.
NOTE:
For optional whole house
filter, connect to the INLET side of
the filter valve (not the softener
valve).
ii.
The treated soft water line connects to
the OUTLET side of the softener
bypass valve.
iii.
Directly push the quick-connect hose
ends into the bypass valve.
e)
For the optional Whole House Filter
Installation, if applicable
, complete the
filter connection to the water softener.
(Skip to the next step if not applicable.)
i.
If using Quick-Connect hose, then
connect
ii.
Plumb the filter OUTLET side to the
water softener INLET side.
1.
Use optional Quick-Connect hose.
(Filter hose bib is not required.)
2.
If optional Quick-Connect hose is
not provided, then plumb a hose
bib with “T” fitting in between the
line from the filter and softener
valves.
iii.
Verify that the filter bypass valve is in
the bypass position.
f)
Reinstall the red clips to secure the fittings.
Gently tug on the clips to make sure they
are locked into place
(B)
STANDARD PLUMBING CONNECTION TO
THE BYPASS VALVE
(If optional Quick-Connect Kit was not
provided.)
The optional treated soft water hose bib is
complete.