Fig. H

Step 8: Tighten all KD SCREWS [R].

FIREPLACE INSERT INSTALLATION:

The fireplace insert can be installed after the mantel has been fully 

assembled.

WARNING: MAKE SURE THE FIREPLACE INSERT CONTROLS ARE 

IN THE OFF POSITION AND THE UNIT IS NOT PLUGGED IN.

Step 1: Place the INSERT on the floor, directly in front of the MAN-

TEL. (The front of both the mantel and insert should be facing the 

same direction).

Step 2: Carefully lift the insert into the mantel opening. The front of 

the INSERT should be flush with the front of the mantel. See fig. I. 

Fig. I

Step 3: Once the INSERT is in place, attach 2 MOUNTING BRACK-

ETS (V) to the bottom with 2 MED-KD SCREWS (W). See fig. J.

Fig. J

Step 4: Attach 2 MOUNTING CLIP (U) on the top of the INSERT. 

Attach 4 MOUNTING SCREWS (S) with the INSERT as shown in 

Fig. K and 2 MEDIUM KD SCREWS (W) and 2 Spacers (Q) with the 

MANTEL UNIT as shown in Fig. L.

Fig. K

Fig. L

Step 5: Move assembled unit to desired location. Unit should not be 

positioned in an area exposed to direct sunlight.

WALL ANCHOR SAFETY CABLE

The use of WALL ANCHOR SAFETY CABLE is highly recommended 

in order to reduce the risk of the fireplace being tipped over acci-

dentally. WARNING: This CABLE may reduce possible risk of injury if 

the fireplace is improperly handled, but is not a substitute for proper 

adult supervision. Children should not be left unattended near any 

heater.
1.  Drill a 5/16 in (8 mm) hole in the wall. Insert the PLASTIC 

WALL ANCHOR into the hole and gently tap until the flange on 

the anchor is against the wall surface.

2.  Position the back edge of the mantle close to the wall.
3.  Attach the SAFETY CABLE to the mantle using the SCREW 

FOR MANTLE. See fig. M.

4.  Use the SCREW FOR WALL to attach the other end of SAFETY 

CABLE to the wall.

5.  Make sure all screws are tight.

Содержание MM480PG-47CW

Страница 1: ...perating and unattended 4 Always unplug fireplace when not in use 5 Do not operate any electric fireplace with a damaged cord or plug or after the heater malfunctions has been dropped or damaged in any manner 6 Do not use outdoors 7 This electric fireplace heater is not intended for use in bathrooms laundry areas and similar indoor locations Never locate heater where it may fall into a bathtub or ...

Страница 2: ...nd such as a properly grounded outlet box The adapter should not be used if a three slot grounded receptacle is available A 15 AMP circuit is required to operate this heater If the breaker trips when the heater is used then you may need to move the heater to another location or unplug other appliances that are on the same circuit If you require an extension cord use one that is rated at 1875 watts...

Страница 3: ... B Fig A Fig B Step 3 Attach the LEFT SIDE PANEL G to the LEFT FRONT PANEL E with 2 KD SCREWS R Attach the RIGHT SIDE PANEL H to the RIGHT FRONT PANEL F with 2 KD SCREWS R See fig C Fig C Step 4 Attach the LEFT E G and RIGHT F H SIDE PANELS to the BASE B using 4 KD SCREWS R 2 screws on each side See Fig D Fig D Step 5 Place the UPPER FRONT PANEL C over both FRONT PANELS E and F and lock in place t...

Страница 4: ... Fig K and 2 MEDIUM KD SCREWS W and 2 Spacers Q with the MANTEL UNIT as shown in Fig L Fig K Fig L Step 5 Move assembled unit to desired location Unit should not be positioned in an area exposed to direct sunlight WALL ANCHOR SAFETY CABLE The use of WALL ANCHOR SAFETY CABLE is highly recommended in order to reduce the risk of the fireplace being tipped over acci dentally WARNING This CABLE may red...

Страница 5: ...ffect The unit will be beep and the indicator light will be ON The bulbs for flame effect log set will be ON To adjust the flame intensity hold down the button the flame optics will go higher or lower Once you have found the desired setting release the button Pressing the button again will stop the light function 750W Press this button for low heat level The unit will beep the pilot light and indi...

Страница 6: ...nc or rechargeable Nickel Cadmium batteries MAINTENANCE WARNING Disconnect power and unplug the power cord before attempting any maintenance or cleaning to reduce the risk of fire electric shock or damage to persons The bulbs in your unit can become extremely hot Allow at least 10 minutes between turning off the unit and removing the light bulbs to avoid the accidental burning of the skin RISK OF ...

Страница 7: ...oles as shown in Fig B Fig B 2 Drill the holes with diameter 3 4 inches 10 mm and depth 3 4 inches 10 mm on the mantel Each PLASTIC CONNECTOR needs 3 holes See Fig C Fig C Fig D 3 Gently install the KD NUTS into the drilled holes with hammer as shown in Fig D 4 Attach the PLASTIC CONNECTOR and lock in place with KD SCREWS as shown in Fig E Fig E Option 2 Use the SMALL L BRACKETS and SCREWS 1 Place...

Страница 8: ...should fail to operate correctly within one year from the date of purchase call customer service at 1 800 459 4409 EST We will at our discretion either repair or replace the unit It will have to be returned to us freight prepaid and we will return the repaired or replaced unit to you freight prepaid The company s sole obligation is to repair or replace the unit This warranty is void if in the opin...

Отзывы: