4
Fig. G
Fig. H
Step 8: Tighten all KD SCREWS [R].
FIREPLACE INSERT INSTALLATION:
The fireplace insert can be installed after the mantel has been fully
assembled.
WARNING: MAKE SURE THE FIREPLACE INSERT CONTROLS ARE
IN THE OFF POSITION AND THE UNIT IS NOT PLUGGED IN.
Step 1: Place the INSERT on the floor, directly in front of the MAN-
TEL. (The front of both the mantel and insert should be facing the
same direction).
Step 2: Carefully lift the insert into the mantel opening. The front of
the INSERT should be flush with the front of the mantel. See fig. I.
Fig. I
Step 3: Once the INSERT is in place, attach 2 MOUNTING BRACK-
ETS (V) to the bottom with 2 MED-KD SCREWS (W). See fig. J.
Fig. J
Step 4: Attach 2 MOUNTING CLIP (U) on the top of the INSERT.
Attach 4 MOUNTING SCREWS (S) with the INSERT as shown in
Fig. K and 2 MEDIUM KD SCREWS (W) and 2 Spacers (Q) with the
MANTEL UNIT as shown in Fig. L.
Fig. K
Fig. L
Step 5: Move assembled unit to desired location. Unit should not be
positioned in an area exposed to direct sunlight.
WALL ANCHOR SAFETY CABLE
The use of WALL ANCHOR SAFETY CABLE is highly recommended
in order to reduce the risk of the fireplace being tipped over acci-
dentally. WARNING: This CABLE may reduce possible risk of injury if
the fireplace is improperly handled, but is not a substitute for proper
adult supervision. Children should not be left unattended near any
heater.
1. Drill a 5/16 in (8 mm) hole in the wall. Insert the PLASTIC
WALL ANCHOR into the hole and gently tap until the flange on
the anchor is against the wall surface.
2. Position the back edge of the mantle close to the wall.
3. Attach the SAFETY CABLE to the mantle using the SCREW
FOR MANTLE. See fig. M.
4. Use the SCREW FOR WALL to attach the other end of SAFETY
CABLE to the wall.
5. Make sure all screws are tight.