PUMP JACK
MODEL # 2200
PUMP JACK
SYSTEM
Customer Supprt and Ordering In for ma tion
781-344-1000 • www.qualcraft.com
The platform arm should be fully decked. See directions
on
Choosing A Walk Plank
for additional requirements.
Work-
bench, Guardrail:
Install guardrails (a top-rail and mid-rail)
by using a guardrail holder or workbench/guardrail combo.
Install toe boards and end-rails in compliance with regulations.
General Requirements:
When appropriate guarding can not
be accomplished, a fall protection system must be used for
each worker on the pump jack system. There should never
be more than two people on the pump jack system between
any two pump jack poles. Pump Jack scaffolding must not
be used above 30 feet. Only one walk plank shall be sup-
ported between any two pump jack poles. An access ladder or
equivalent safe access to the work platform must be provided.
The employer must provide appropriate training on the setup
and safe use of this product.
Instructions on Use:
To raise the pump jack platform:
1) Stand on walk plank with
the jack and pole in front of you, lock the crank by sliding the
crank handle to the right or left until the square rod is seated
into the square hole. 2) Place your foot in the stirrup and pump
slowly until the platform is raised approximately 1 foot. 3)
Repeat this procedure to the other pump jacks. Always keep
the walk plank level. 4) IMPORTANT – Raise the stirrup to the
“up” position when desired height is reached.
To lower the pump jack platform:
1) With your back to the
work wall, face the pole and raise the stirrup to the “up” posi-
tion. 2) Unlock the crank by sliding the handle to the right or
left until it turns freely. 3) With one hand holding onto the pole
and the other fi rmly gripping the crank handle, place one foot
on the square pedal of the lower lock press down and hold
open. 4) Turn crank to lower platform approximately one foot.
5) Repeat procedure with the other pump jacks. Always keep
work surface level. 6) IMPORTANT – Raise the stirrup to the
“up” position when desired height is reached.
To pass a pump jack brace:
1) When passing a pump jack
brace that is already installed, an extra brace should be in-
stalled approximately 4 feet above the one to be passed until