quadral AURUM M10 Скачать руководство пользователя страница 9

ENGLISH

17

16

Stereo connection

(speaker B)

8

You may now switch your M10 on using the power switch.

9

Move the power switch (9) on the rear side of the device to the ON position. The LED on the 
front panel will now come on.

10

The M10 is switched on together with the Pre-Amplifier, if there is a LINK connection between 
them.

11.

 

If there is no LINK connection, you additionally have to press button (4) on the M10 front panel.

Note:

 

Your M10 use a special power-saving standby circuit, you can always switch on / off during 
normal operation using the On / Standby button on the unit.

Technical Data M10

Input sensitivity for 1 W at 4 ohms

-26 dBV

Input impedance

47 kOhm

Voltage gain Stereo resp. Mono

23/32/35 dB resp. 29/38/41 dB

Maximum input voltage

6 V

Maximum voltage at speaker output (Stereo)

44 V

Maximum voltage at speaker output (Mono)

72 V

Minimum loudspeaker impedance (Stereo)

2 ohms

Minimum loudspeaker impedance (Mono)

2 ohms

Stereo output power at 8 ohms

240 W

Stereo output power at 4 ohms

400 W

Mono output power at 8 ohms

650 W

Mono output power at 4 ohms

1000 W

Frequency response

1 Hz - 110 kHz (-3 dB)

Harmonic distortion

< 0.03%

A-weighted signal-to-noise ratio Stereo resp. Mono

-79/-78/-77 dB resp. -79/-75/-76 dB

Mains power connection

115V / 230V, switchable

Power consumption (in normal mode) Stereo resp. Mono

35 W resp. 30 W

Power consumption (at maximum volume) 

max. 2200 W

Power consumption (in standby mode)

< 0.3 W

Inputs

2 pairs of RCA, 1 pairs of XLR

Speaker outputs

2 x pair 

12V Link Connection In + Out (short-circuit-proof)

3.5 mm Mono minijack

Protective circuits

Temperature, overload

Dimensions (W x H x D)

453 x 130 x 400 mm*

Weight

21,48 kg  

* Width including wooden sides, Height including feet, Depth with speaker terminals

Operating mode / Connection type

GAIN-switch on the rear side

Mono / XLR

- 10 dB

Mono / Cinch (RCA)

- 10 dB

Stereo / XLR

± 0 dB

Stereo / Cinch (RCA)

optional 0 dB / + 3 dB

Fuse:

 

100V/115V:  T250 mA  L250V
230V:           T125 mA  L250V

~50/60 Hz

max. Power Cons.: 10W

quadral GmbH  & Co. KG - Am Herrenhäuser Bahnhof 26-28  - D-30419 Hannover

On

Off

Out 2 

L

R

Out 1 

L

R

Out 3

R

L

R

L

R

L

R

L

Aux

Tuner

CD

Phono

L2

L1

R2

R1

Direct

Bypass

40 

600 

120 

R/L 2

MC

MM

R/L 1

Phono Switches

XLR 2 

L

R

XLR 1 

L

R

Phono

GND

USB

TosLink

SPDIf

Digital In

Link

Out

Handmade in Germany

W A R N I N G :

TO  REDUCE  THE  RISK 
OF  ELECTRICAL  SHOCK 
OR FIRE, DO NOT EXPOSE
THIS 

APPLIANCE 

TO 

MOISTURE 

OR 

RAIN.

DO  NOT  REMOVE  COVER.  NO  USER

SERVICEABLE  PARTS  INSIDE.  REFER 

SERVICING  TO  QUALIFIED  PERSONNEL.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

+

+

XLR Stereo connection

Switch position XLR and Stereo

Front lighting: ON / OFF

Unbalanced / Balanced

Mono / Stereo

Gain  +3 dB / 0 dB / -10 dB

max. Power Consumption: 2,2kW

Fuse:  inside

O
F
F

O
N

110-120V  -  50-60 Hz

220-240V  -  50-60 Hz

Voltage select

Left B+

Left B-

Left A-

Left A+

Mono -

quadral GmbH & Co. KG - Am Herrenhäuser Bahnhof 26-28 - D-30419 Hannover

Handmade in Germany

Do   NOT  REMOVE 

COVER. 

NO  USER

SERVICEABLE 

PARTS  INSIDE. 

 R EFER  

SERVICING 

TO  QUALIFIED 

PERSONNEL.

CAUTIO N

RISK OF ELECTRIC SHOC K

DO NOT OPEN

Right

Left

Mono

Unbalanced

Balanced

Mono

Right

Left

Right B-

Right A-

Right B+

Right A+

Mono+

Frontlight: ON / OFF

Unbalanced / Balanced

Mono / Stereo

Gain  +3 dB / 0 dB / -10 dB

Link

IN

OUT

Pre-Amplifier AURUM P8 (Example)

Содержание AURUM M10

Страница 1: ...ENGLISH DEUTSCH BEDIENUNGSANLEITUNG USER INSTRUCTIONS AURUM M10 Endverst rker Amplifier...

Страница 2: ...iehen des Netzsteckers nicht aber an dem Kabel selbst erfolgen Die Lautsprecheranschlussklemmen des Verst rkers d rfen nur mit den betreffenden Eing ngen der Lautsprecher verbunden werden Eine irgendw...

Страница 3: ...en im Geh use dienen der Entl ftung und sorgen f r zuverl ssigen Betrieb Daher d rfen sie nicht verstellt oder abgedeckt werden Bei einer massiven berlastung der Ger te durch sehr gro e Lautst rken is...

Страница 4: ...Arbeitspunkte stabilisiert sind und eine Signalfreigabe erfolgen kann 1 2 3 1 4 5 6 7 9 8 10 11 12 13 max Power Consumption 2 2kW Fuse inside O F F O N 110 120V 50 60 Hz 220 240V 50 60 Hz Voltage sel...

Страница 5: ...aar 12V Link Anschluss In Out Kurzschlu fest 3 5 mm Mono Miniklinke Schutzschaltungen Temperatur berlast Abmessungen B x H x T 453 x 130 x 400 mm Gewicht 21 48 kg Breite mit Holzseitenteilen H he mit...

Страница 6: ...or damaged by furniture are being trodden on and or that nobody will trip over them Take the power plug out of the socket during lightening storms or if the equipment will not be used for a long time...

Страница 7: ...s dropped or if liquid seeps into it Never open the equipment as you might touch the mains voltage 230V 115V which is dangerous Only use furniture and other units for attaching and putting the equipme...

Страница 8: ...ersal Mono connection Left Channel 1 2 3 1 4 5 6 7 9 8 10 11 12 13 Fuse 100V 115V T250 mA L250V 230V T125 mA L250V 50 60 Hz max Power Cons 10W quadral GmbH Co KG Am Herrenh user Bahnhof 26 28 D 30419...

Страница 9: ...In Out short circuit proof 3 5 mm Mono minijack Protective circuits Temperature overload Dimensions W x H x D 453 x 130 x 400 mm Weight 21 48 kg Width including wooden sides Height including feet Dept...

Страница 10: ...19 18...

Страница 11: ...quadral GmbH Co KG Am Herrenh user Bahnhof 26 28 D 30419 Hannover Phone 49 0 511 79 04 0 Fax 49 0 511 79 04 444 e mail info aurumelectronic com Internet www aurumelectronic com facebook com quadralhif...

Отзывы: