Mounting the Cylinders
Make sure weld-on bracket is mounted vertically, it is easiest to bolt the cylinder to the bracket, then place up to
the frame with a floor jack, verify that the jack is at appropriate height (typically 9-11” off the ground) and
vertically level, then proceed to getting full weld from bracket to frame. Cylinders may also be bolted directly to
the frame, however included hardware may not be long enough, make sure you replace with 7/16” grade-8
hardware, minimum of four for 8k and 12k jacks, and six for 17k and 24k jacks. For slave systems you have
options for plumbing, you can place the “tee” fittings on the pump or you can place them both on one of the
jacks. Cylinder, mounting bracket, weld-on bracket and footpad may vary from application to application. For
different brackets, cylinders or footpads feel free to call!
Limit switch not required
for 1pt & 2pt Systems
7” FOOT PAD
#M27610