7
March 17, 2020
7080-166J
Model
Numbers:
TREKKER-MBK, TREKKER-PBK,
TREKKER-PDB, TREKKER-PFT,
TREKKER-PMH and TREKKER-TWL
Laboratory:
OMNI Test Laboratories, Inc.
Report
Number:
061-S-83-2
Type:
Solid Fuel Room Heater, Pellet Fuel
Burning Type
Standard:
ASTM E1509-12 , ULC S627-00 and
(UM) 84-HUD,
Mobile Home Approved.
FCC:
Complies with Part 15 of FCC Rules.
Operation is subject to the following two
conditions:
(1) this device may not cause harmful
interference, and
(2) this device must accept any
interference received, including
interference that may cause undesired
operation.
This pellet appliance needs periodic inspection and repair for proper operation. It is against federal regulations to operate
this pellet appliance in a manner inconsistent with the operating instructions in the owner’s manual.
1
Listing and Code Approvals
A. Appliance Safety Certification
NOTICE:
This installation must conform with local codes. In the absence of local codes you must comply with the
ASTM E1059-12, ULC S627-00, (UM) 84-HUD and ULC/ORD-C-1482
.
C. BTU & Efficiency Specifications
EPA Certification
Number:
Number: 98-17
EPA Certified Emissions:
0.74 grams per hour
*LHV Tested Efficiency:
83.2%
**HHV Tested Efficiency:
77.9%
***EPA BTU Output:
12,682 to 39,428 / hr.
****BTU Input:
16,396 to 50,775 / hr.
Vent Size:
3” or 4” Type “L” or “PL”
Hopper Capacity:
80 lbs.
Fuel:
Premium Wood Pellets
* Weighted average LHV (Low Heating Value) efficiency
using data collected during EPA emissions tests in
accordance with the requirements of CSA B415.1.
** Weighted average HHV (High Heating Value) efficiency
using data collected during EPA emissions tests in
accordance with the requirements of CSA B415.1.
*** A range of BTU outputs calculated using HHV
efficiency and the burn rates from the EPA tests.
**** Based on the maximum feed rate per hour multiplied
by approximately 8600 BTU’s which is the average BTU’s
from a pound of pellets.
The
TREKKER-MBK, TREKKER-PBK,
TREKKER-PDB, TREKKER-PFT,
TREKKER-PMH and TREKKER-TWL
are Certified to comply with 2020
particulate emission standards.
Model
Number:
TREKKER-MBK, TREKKER-PBK,
TREKKER-PDB, TREKKER-PFT,
TREKKER-PMH and TREKKER-TWL
Laboratory:
OMNI Test Laboratories, Inc.
Report
Number:
0061PS094E
Standard:
ASTM E1509-12. ASTM E2779 and
CSA B415.1-10.
Can be found at:
www.quadrafire.com/about-us/epa-certification
B. Appliance Emissions Certification