A. Component Functions

1.  Exhaust Blower

The combustion (exhaust) blower is mounted in the bottom right rear of appliance. The blower is designed to pull the 

exhaust from the appliance and push it out through the venting system.

2.  Control Board

The control board is located on the right side of appliance. It controls the functioning of the appliance and 

communicates with the user interface through the Bluetooth key. The control board can only be replaced by an 

authorized dealer.

3.  Convection Blower

The convection blower is mounted at the bottom left of the appliance. The convection blower pushes heated air 

through the heat exchange system into the room.

4.  Feed System

The feed system is located on the right side of the appliance and can be removed as an entire assembly. The hollow 

feed spring (auger) pulls pellets up the feed tube from the hopper area and drops them down the feed chute into the 

fire pot. Reference the parts list for individual parts in feed assembly.

5.  Fire pot

The fire pot is made of high quality ductile iron. The floor of the fire pot opens for cleaning and is manually operated 

by the homeowner. The floor needs to return to a completely closed position or the appliance will not operate properly.

6.  Fuse

The control board fuse will blow should a short occur. The control board will need to be replaced. DO NOT REPLACE 

THE FUSE. If the control board fuse blows its TRIAC, that portion of the circuit, will remain closed causing the motor 

on that leg to run continuously at high speed.

7.  Heat Exchanger

The heat exchanger is located behind the baffle and transfers heat from the exhaust system into the convection air 

chamber. Remove the cast iron baffle to access the heat exchanger.

8.  Hopper Lid Switch

The hopper lid switch is located on the right side, inside the hopper. It switches the feed motor off if the hopper lid is 

open.

9.  Igniter (Heating Element)

The igniter is mounted on the base of the fire pot. Combustion air travels over the red hot igniter creating super 

heated air that ignites the pellets.

10. Power Receptacle

The power receptacle is located below the control box on right side. Install the power cord (supplied in the appliance 

component pack) to the appliance receptacle. Prior to installing, check the wall receptacle for 120 volt, 60 Hz 

(standard current). Make sure the outlet is grounded and has the correct polarity. A good quality surge protector is 

highly recommended to protect the appliance electronics.

11.  Overheat Snap Discs

There are two overheat snap discs located within the electro-mechanical cavity of the appliance. One is mounted on 

the back of the drop tube in the center of the appliance; the other is mounted in the RH side between the firebox and 

cast side panel. Both snap discs have a reset button. If the fire tries to burn back into the feed system, the drop tube 

snap disc will shut the appliance down. If there is not enough circulation from the convection blower the second snap 

disc will shut the feed system off. Either sensor must be manually re-set if tripped. Disconnect power before resetting.

Reference Materials

Содержание TREKKER Series

Страница 1: ...NING If the information in these instructions is not followed exactly a fire could result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and li...

Страница 2: ...oors tightly closed during operation Keep viewing and ash removal doors tightly closed during operation Conforme la norme ASTM E1509 12 Std Certifi la norme ULC S627 00 Room Heating Pellet Burning Typ...

Страница 3: ...Prop65 9 2 Operating Instructions 10 A Fire Safety 10 B Non Combustible Materials 10 C Combustible Materials 10 D Fuel Material and Fuel Storage 10 E Before Your First Fire 11 F Filling the Hopper 11...

Страница 4: ...pilots blowers junction boxes wire harnesses transformers and lights excluding light bulbs X X Molded Refractory Panels Glass Liners X Vent Free Burners Vent Free Logs X X Castings Medallions and Baf...

Страница 5: ...ot covered by this warranty Limited Catalyst Warranty o For wood burning products containing a catalyst the catalyst will be warranted for a six year period to the original purchaser at catalyst WARRA...

Страница 6: ...blower will run for about 45 seconds wait for it to stop before moving to manual feed 65 72 HEATING 5 From the OFF home screen press and hold the outer ring for 3 seconds to access the main menu 6 Rot...

Страница 7: ...A Certification Number Number 98 17 EPA Certified Emissions 0 74 grams per hour LHV Tested Efficiency 83 2 HHV Tested Efficiency 77 9 EPA BTU Output 12 682 to 39 428 hr BTU Input 16 396 to 50 775 hr V...

Страница 8: ...used to operate this product wood and the products of combustion of such fuels can expose you to chemicals including carbon black which is known to the State of California to cause cancer and carbon m...

Страница 9: ...content Higher Ash Content Material Hardwoods with a high mineral content Fuel that contains bark Standard grade pellets or high ash pellets Lower Ash Content Material Most softwoods Fuels with low mi...

Страница 10: ...increases heat the blower will increase its output F Filling the Hopper Open the hopper lid by lifting the handle Fill the hopper with fuel Close the hopper lid The unit will not feed with the hopper...

Страница 11: ...own existing fuel in the fire pot will continue to burn without the feed motor run ning but the exhaust and convection blowers will remain on until the exhaust has cooled HOT WHILE IN OPERATION KEEP C...

Страница 12: ...e before making another adjustment A properly adjusted fire will have a bright active flame pattern that extends out of the fire pot approximately 6 to 9 inches when burning on high A properly adjuste...

Страница 13: ...servicing What is the metal object with the bend in it that came inside the plastic bag It is a clean out tool used to help clean the fire pot and remove any jams in the rare event they occur in the f...

Страница 14: ...liance Visit www quadrafire com owner resources to view basic troubleshooting FAQs use care videos We recommend annual service by a qualified dealer Cleaning or Inspection Frequency Daily Weekly Month...

Страница 15: ...aterials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have thoroughly cooled O...

Страница 16: ...Tools Needed A Shop Vacuum and generic micro cleaning kit flat head screwdriver bottle brush and a ID hose a It is necessary to remove the baffle to gain access to the heat exchanger Figure 16 2 foll...

Страница 17: ...ng above the fire pot bottom approximately 1 16 inch 1 59mm or more it means the springs have lost their tension Lost tension cannot keep the floor in the proper position causing ignition problems and...

Страница 18: ...lace fan make sure elect connections are fully assembled 11 Cleaning Convection Blower Requires No Lubrication Frequency See chart on page 14 By Homeowner a Be sure the appliance is allowed to cool b...

Страница 19: ...e top of the latch up to lock latch into place G Glass Replacement 1 Swing open the face and remove the door from the appliance by lifting the door off of the hinge pins and lay on a flat surface face...

Страница 20: ...acing the bottom flange into the opening first then rotate blower up into position 8 When the blower is properly positioned the latch will engage the notch to hold the blower in place Figure 20 1 9 Re...

Страница 21: ...ration Check hopper switch wires for integrity Check hopper lid on correctly Check hopper lid magnet is installed Safety snap disc is tripped not functioning Check to make sure convection blower wires...

Страница 22: ...haust probe to exhaust blower housing keeping its wire away from hot surfaces Defective probe Replace probe Control board is defective Replace control board Convection Blower fails to shut off Wire sh...

Страница 23: ...e termination further from the structure Excessive feeding incorrect air fuel ratio Adjust the tuning see tuning section Unit rumbles consistently during burns Too much fuel Turn tuning down one numbe...

Страница 24: ...probe not properly installed Secure exhaust probe to exhaust blower housing keeping its wire away from hot surfaces Igniter chamber plugged with debris Clean igniter chamber 2 Exhaust Probe Fail Not...

Страница 25: ...blows its TRIAC that portion of the circuit will remain closed causing the motor on that leg to run continuously at high speed 7 Heat Exchanger The heat exchanger is located behind the baffle and tra...

Страница 26: ...ng via screw and clamp It provides sympathetic exhaust temperature feedback to the control board In turn the control board uses this information to adjust its heat output systems for best performance...

Страница 27: ...27 March 17 2020 7080 166J Date of Service Performed By Description of Service B Maintenance Log...

Страница 28: ...5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 22 21 23 24 25 26 27 28 29 30 31 32 33 34 35 6 Color SKU No Mfg Dates Matte Black TREKKER MBK 06 18 Porcelain Black TREKKER PBK 06 18 05 19 Porcelain Dark B...

Страница 29: ...MH Sienna Bronze 7034 157CSB Twilight 7034 157TWL Gasket Hopper Lid 10 FT 7000 320 10 2 Hinge Pin SRV7034 159 3 Hinge Retainer SRV7034 163 4 Top Matte Black 7034 155MBK Porcelain Black 7034 155PBK Por...

Страница 30: ...080 022 12 1 Glass Retainer 7034 136 Y 12 2 Glass Assembly w Gasket 7034 007 Y Gasket Channel 1 8 x 1 1 4 x 10 7000 377 10 12 3 Hinge Female SRV450 2910 12 4 Door Latch Assembly 413 5200 13 Front Face...

Страница 31: ...32 Y 17 Intake Shield 7034 224 Y 18 Firepot Riser Assembly Does Not Include Floor Lever Assembly SRV7080 082 18 1 Firepot Assembly SRV7080 083 Y 18 2 Gasket Firepot SRV7034 190 Y 18 3 Spring Pkg of 4...

Страница 32: ...Right SRV7080 168 28 Combustion Blower SRV7080 106 Y Combustion Blower Gasket Between Housing and Stove SRV7080 117 Y Combustion Blower Motor Gasket Between Motor and Housing SRV7080 107 Y 29 Flue Col...

Страница 33: ...01 24 Screw Sheet Metal 8 X 1 2 S Grip Pkg of 40 12460 40 Y Screw Machine Screw 1 4 20 x 5 8 Pkg of 24 220 0440 24 Screw Pan Head Phillips 8 32 X 3 8 Pkg of 40 225 0500 40 Y Washer Sae 10 Pkg of 25 22...

Страница 34: ...and maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance...

Отзывы: