background image

4

Quadra-Fire  •  Topaz  •  7009-113  Rev. Q  •  6/14

1

Listing and Code Approvals

The  product  is  listed  to ANSI  standards  for  “Vented  Gas 

Appliance Heaters” and applicable sections of “Gas Burning 

Heating Appliances  for  Manufactured  Homes  and  Recre-

ational Vehicles” and "Gas Fired Appliances for use at High 

Altitudes". 

A.  Appliance Certi

fi

 cation

B.  Glass Speci

fi

 cations

NOTE:  

This installation must conform with local codes. In the 

absence of local codes you must comply with the 

National 

Fuel Gas Code, ANSI Z223.1-latest edition 

in the U.S.A. 

and  the 

CAN/CGA  B149  Installation  Codes 

in  Canada.

D.  High Altitude Installations

Omni-Test Laboratories listed gas appliances are tested and 

approved without requiring changes for elevations from 0 to 

2000 feet in the U.S.A. and 0 to 4500 feet in Canada.

When installing this appliance at an elevation above 2000 

feet,  it  may  be  necessary  to  decrease  the  input  rating  by 

changing the existing burner ori

fi

 ce to a smaller size. Input 

rate should be reduced by 4% for each 1000 feet above a 

2000 foot elevation in the U.S.A.  If the heating value of the 

gas has been reduced, these rules do not apply. To identify 

the proper ori

fi

 ce size, check with the local gas utility.

If installing this appliance at an elevation above 4500 feet (in 

Canada), check with local authorities.

C.  BTU Speci

fi

 cations

This appliance is equipped with 5mm ceramic glass.  Replace 

glass  only  with  5mm  ceramic  glass.    Please  contact  your 

dealer for replacement glass.

WARNING

Do NOT use this appliance if any part has been under water. 

Immediately call a quali

fi

 ed service technician to inspect 

the unit and to replace any part of the control system and 

any gas control which has been under water.

Manufactured Home or Mobile Home installation may occur 

only after the home is site located and must conform with 

the Manufactured Home Construction and Safety Standard, 

Title  24  CFR,  Part  3280,  or,  when  such  a  standard  is 

not  applicable,  the  Standard  for  Manufactured  Home 

Installations,  ANSI/NCSBCS  A225.1,  or  Standard  for  Gas 

Equipped Recreational Vehicles and Mobile Housing, CSA 

Z240.4.

When installed, the appliance must be electrically grounded 

in accordance with local codes or, in the absence of local 

codes, with the National Electrical Code, ANSI/NFPA 70, or 

the Canadian Electrical Code, CSA C22.1.

MODEL:

Topaz

LABORA-

TORY:

OMNI Test Laboratories, Inc.
061-S-24-5

TYPE:

Direct Vent Gas Heater

STANDARD:

ANSI Z21.88a-2000

ּ

CSA 2.33a-M00

ּ

  

UL307b

ּ

CAN/CBA 2.17-M91

Materials  that  are  reported  as  passing  ASTM  E  136, 

Standard  Test  Method  for  Behavior  of  Materials  in  a 

Vertical Tube Furnace at 750°C, shall be considered non-

combustible materials.

Materials  made  of  or  surfaced  with  wood,  compressed 

paper, plant fibers, plastics, or other materials that can ignite 

and burn, whether flame proofed or not, or whether plastered 

or unplastered shall be considered combustible materials.

E.   Non-Combustible Materials

F.   Combustible Materials

Model

(US or Canada)

Maximum Input 

BTU

Minimum Input 

BTU

Ori

fi

 ce Size 

Top Vent

Topaz (NG)

39,500

26,500

.125

Topaz (LP)

38,000

30,500

.073

Rear Vent

Topaz (NG)

35,000

23,500

.113

Topaz (LP)

27,500

16,500

.063

Содержание TOPAZ Direct Vent Room Heater 839-1290

Страница 1: ... or death This appliance may be installed as an OEM installation in manufactured home USA only or mobile home and must be installed in accordance with the manufacturer s instructions and the manufactured home construction and safety standard Title 24 CFR Part 3280 or Standard for Installation in Mobile Homes CAN CSA Z240MH This appliance is only for use with the type s of gas indi cated on the rat...

Страница 2: ...hnicien qualifeé et ou muni d une licence de manière à respecter les règlements municipaux Dans la République de Massachusetts l installation doit être effectuée par un plombier ou un installateur d appareils à gaz agrée This appliance must be installed in accordance with the current Standard CAN CSA Z240 MH Mobile Housing or with Manufactured Home Construction and Safety Standard Title 24 CFR Par...

Страница 3: ...Conversions 23 B Gas Pressures 25 C Gas Connection 26 Section 7 Electrical Information A Recommendation for Wire 27 B Connecting to the Appliance 27 C Standing Pilot Ignition System Wiring 27 Section 8 Appliance Setup A Remove Shipping Materials 29 B Top to Rear Vent Conversion 29 C Leg Leveling System 30 D Accessories 30 E Front Installation 31 F Brick Installation 31 G Positioning the Logs 32 H ...

Страница 4: ...ass WARNING Do NOT use this appliance if any part has been under water Immediately call a qualified service technician to inspect the unit and to replace any part of the control system and any gas control which has been under water Manufactured Home or Mobile Home installation may occur only after the home is site located and must conform with the Manufactured Home Construction and Safety Standard...

Страница 5: ...nt terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS G Requirements for the Commonwealth of Massachusetts Inspection The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installa tion...

Страница 6: ... Remove log set and component pack from firebox Report to your dealer any parts damaged in shipment particularly the condition of the glass Read all of the instructions before starting the instal lation Follow these instructions carefully during the installation to ensure maximum safety and benefit Keep appliance dry Mold or rust may cause odors Water may damage controls WARNING Installation and u...

Страница 7: ...nce to all clearance specifications in manual WARNING B Clearances Figure 3 1 Model A B C D E F G Topaz Inches 6 1 2 6 1 54 36 40 23 Millimeters 165 152 25 1372 914 1016 584 NOTE Flooring beneath appliance may reach 90 degrees plus room ambient temperature Check with flooring manufacturer for maximum temperature allowed on flooring surfaces It is permissible to place the appliance on carpet CAUTIO...

Страница 8: ... LOWEST DISCHARGE OPENING Roof Pitch H Min Ft Flat to 6 12 1 0 Over 6 12 to 7 12 1 25 Over 7 12 to 8 12 1 5 Over 8 12 to 9 12 2 0 Over 9 12 to 10 12 2 5 Over 10 12 to 11 12 3 25 Over 11 12 to 12 12 4 0 Over 12 12 to 14 12 5 0 Over 14 12 to 16 12 6 0 Over 16 12 to 18 12 7 0 Over 18 12 to 20 12 7 5 Measure vertical clearances from this surface Measure horizontal clearances from this surface See Figu...

Страница 9: ...MAX 1 cap 3 feet 2 x Q ACTUAL 2 caps 6 feet 1 x Q ACTUAL 3 caps 9 feet 2 3 x Q ACTUAL 4 caps 12 feet 1 2 x Q ACTUAL QMIN termination caps x 3 RMA X 2 termination caps xQACTUAL N 6 inches non vinyl sidewalls 12 inches vinyl sidewalls P 8 ft Alcove Applications NOTE 1 On private property where termination is less than 7 feet above a sidewalk driveway deck porch veranda or balcony use of a listed cap...

Страница 10: ...agonal runs have both vertical and horizontal vent aspects when calculating the effects Use the rise for the vertical aspect and the run for the horizontal aspect See Figure 5 1 Two 45 elbows may be used in place of one 90 elbow On 45 runs one foot of diagonal is equal to 8 1 2 in 216mm horizontal run and 8 1 2 in 216mm vertical run A length of straight pipe is allowed between two elbows See Figur...

Страница 11: ...is 6 in 152mm Horizontal sections require a 1 4 in 6mm rise for every 12 in 305mm of horizontal travel Exterior Vent Diameter 6 5 8 in 168mm Inner Vent Diameter 4 in 102mm Horizontal sections require noncombustible support every 3 ft 914mm e g wall straps For any vertical termination a minimum of 6 ft 1 8m vertical must be used EXCEPTIONS FOR HORIZONTAL INSTALLATIONS When installing the Topaz in a...

Страница 12: ...twist lock adapter is built into the appliance at the factory Wall thickness may vary Remember to include wall thickness in minimum clearances when figuring venting lengths for your installation needs Note Female ends of direct vent pipe elbows are designed to slide straight onto the male ends of adjacent pipes by orienting the pipe indentations so they match and slide into the entry slots on the ...

Страница 13: ...grade i e basement application proper drainage must be provided to prevent water from entering the snorkel termination Do not backfill around snorkel termination HOT WOOD SCREW WALL THIMBLE Step 4 Position the horizontal termination cap in the center of the 10 in x 10 in 254mm x 254mm square hole and run a bead of non hardening mastic around its outside edges so as to make a seal between it and th...

Страница 14: ...top to vinyl standoff SCREWS Apply sealant to all four sides VINYL SIDING Figure 5 8 8 in 203mm 7 in 178mm 7 in 178mm 6 in 152mm Figure 5 7 NOTE Some termination caps may cause the vent pipe to be off center on flashing Ensure that proper clearances to combustible materials are maintained If you are not using an approved termination cap with a built in vinyl siding standoff on a building with viny...

Страница 15: ...ep 2 Set the gas appliance in its desired location Drop a plumb bob down from the ceiling to the position of the appliance flue exit and mark the location where the vent will penetrate the ceiling Drill a small hole at this point Next drop a plumb bob from the roof to the hole previously drilled in the ceiling and mark the spot where the vent will penetrate the roof Determine if ceiling joists roo...

Страница 16: ...requirements as outlined in the current CAN CGA B149 Installation Codes in Canada the National Fuel Gas Code NFPA 54 ANSI Z223 1 in USA or local codes Note that for steep roof pitches the vent height must be increased See Roof Pitch Table Figure 4 3 on page 8 In high wind conditions nearby trees adjoining rooflines steep pitched roofs and other similar factors can result in poor draft or down draf...

Страница 17: ...ramed and sheetrocked with standard construction materials however refer to these installation instructions for the minimum allowable clearance between the outside of the vent pipe and the combustible surfaces of the enclosure Do not fill any of the required air space with insulation Step 9 Twist lock the vent cap and seal Note For multi story vertical installations a ceiling firestop is required ...

Страница 18: ...athing Step 5 Using tin snips cut the support box from the top corners down to the roofline and fold the resulting flaps over the roof sheathing Figure 5 18 Before nailing it to the roof run a bead of non hardening mastic around the top edges of the support box to make a seal between it and the roof Clean out any combustible material from inside the support box Step 6 Complete the cathedral ceilin...

Страница 19: ...m Connect the flex pipe to the retro connector and attach with sheet metal screws Step 6 Push the flex pipe back up into the ceiling support box center the retro connector and attach it to the support box with sheet metal screws Step 7 The connection between the appliance and the retro connector may be completed with sections of direct vent pipe Top Adapter Sheet Metal Screws Flex Pipe Figure 5 21...

Страница 20: ...ex Liner Pipe Length Optional Chimney Liner Termination Cap Co Axial to Co Linear Connector 30 ft 9m of 3 in 76mm Flex Liner Exhaust Section Pipe Length Optional 4 ft 1m of 3 in 76mm Flex Liner Air Intake Section The chimney must be sealed from the 4 ft 1m section to termination using a smoke shelf or a damper The seal should be 6 in 152mm below the end of the 4 ft 1m Air Intake section This secti...

Страница 21: ...ngth extended to its nominal length Be sure to leave 2 3 in 51 76mm of flex above the existing chimney to allow for connection to the termination kit Step 3 Secure the flashing to the top of the masonry chimney using a bead of non hardening sealant adhesive If the flashing is larger than the top of the chimney cut and fold flashing as needed to fit chimney Figure 5 26 Step 5 Connect the flex liner...

Страница 22: ...e the top adapter to the flashing Use three sheet metal screws through the side of the top adapter into the flange on the flashing Figure 5 28 Twist lock the high wind termination cap on to the top adapter Figure 5 28 Flex Liner Flex Coupler Sheet Metal Screws Figure 5 27 Figure 5 29 Figure 5 30 Step 10 Slide wall thimble cover over retro connector and secure with masonry bolts Figure 5 30 If you ...

Страница 23: ...and lifting the burner out Figure 6 3 Remove the three screws on the front of the burner support Set screws aside Figure 6 5 Remove the main burner orifice using a 5 8 in wrench and replace the orifice with the proper size as indi cated below for your gas type and venting TOOLS REQUIRED Power drill a 90 handle is helpful 2 Phillips bit 5 32 in Allen wrench 5 8 in open end wrench KIT CONTENTS Repla...

Страница 24: ...emove the rods and adapter cap Fire Risk Explosion Risk Disconnect any electrical cords and turn off gas supply to unit before proceeding if converting fuel on an appliance already fully installed WARNING Replace pilot injector with the one supplied with the appli ance 35 for Propane 62 for Natural Gas Replace pilot hood snapping it into position making sure notch and tab line up Reinstall burner ...

Страница 25: ...low Proper input pressures required for optimum appliance per formance gas line sizing requirements need to be followed from NFPA51 WARNING Fire Risk Explosion Hazard High pressure will damage valve Disconnect gas supply piping BEFORE pressure testing gas line at test pressures above 1 2 psig Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 1 ...

Страница 26: ... local building codes if any If not follow ANSI Z223 1 Instal lation should be done by a qualified installer approved and or licensed as required by the locality In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter Leak test all gas line joints and the gas control valve prior to and after starting the fireplace Before making the gas connection ens...

Страница 27: ...tat see individ ual thermostat instructions to ensure proper operation of appliance 4 Use low resistance thermostat wire for wiring from igni tion system to the wall switch and thermostat 5 Use the following chart for wire sizing 6 Keep wire lengths as short as possible by removing any excess wire length 7 Low voltage and 110 VAC voltage cannot be shared within the same wall box Wire Size Max Leng...

Страница 28: ...ntrols Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Shock hazard Replace damaged wire with type 105O C rated wire Wire must have high temperature insulation CAUTION Red 28 in 711mm Ignitor Switch ON OFF Thermopile Gas Pilot Ignitor Thermocouple VALVE Red 28 in 711mm ...

Страница 29: ...alling as indi cated in Figure 8 6 Figure 8 2 Remove inner collar adapter KIT CONTENTS Rear vent grille NG orifice 113 LP orifice 063 TOOLS REQUIRED Power drill 2 Phillips bit high temp silicone sealant optional Figure 8 3 Remove rear valve cover shield Remove rear access plate and gasket Save the screws Figure 8 4 Place cover plate and gasket over top vent and attach with the four screws previous...

Страница 30: ...ed safely WARNING C Leg Leveling System Figure 8 8 Thread Allen bolts through nuts until flush The Allen bolts and nuts are included in the component pack inside the appliance firebox Figure 8 9 Slide assembled nuts and bolts into the slots on the legs with the nuts on the bottom Figure 8 10 Use a 5 32 in 4mm Allen wrench to adjust legs up and down to desired level Figure 8 6 Install vent pipe ada...

Страница 31: ...S FOR QUARTET AND SOLITAIRE FACE OPTIONS Figure 8 11 Solitaire Front Quartet Front Spacer NOTE The brick supplied with the Topaz is not an optional accessory The brick must be installed for safe and proper operation F Brick Installation Figure 8 15 Install rear panel by placing it behind the log pins flush and centered against the back of the firebox NOTE Rear panel and top panel baffle are the sa...

Страница 32: ...talled side panel and support the other end with one hand Install the remaining side panel and bend over the tabs to hold it in place Rest top panel baffle on sides and slide top panel baffle left or right until centered Figure 8 18 Fully installed brick set Note that with the brick installed the firebox is narrower at the back than in the front G Positioning the Logs While still breakable the log...

Страница 33: ...te your log set application reinstall the glass and the front of the unit H Mineral Wool Follow ember placement instructions in manual Do NOT place embers directly over burner ports Replace ember material annually Explosion Risk WARNING Improperly placed embers interferes with proper burner operation Figure 8 25 Place individual pieces of embers in front of and around the gas log where they can be...

Страница 34: ...ng Place blower under appliance Attach blower from front with 4 screws to blower bracket Figure 8 27 Install snap disc in bracket Attach bracket to fire box with 5 16 in wrench Figure 8 28 Connect electrical connector to snap disc TOOLS REQUIRED 2 Phillips head bit hand drill 11 16 in wrench and a 5 16 in wrench Attach with 4 screws nap isc Bracket 5 16 nut I Glass Door Assembly Replacement Remove...

Страница 35: ...Fire Topaz 7009 113 Rev Q 6 14 Figure 8 31 Blower Wiring Diagram Fan Speed Control Thermal Disc 110 VAC Power Cord BLAC K Bushing Strain Relief GREEN BLACK Ground Fan Assembly BLACK BLACK WHITE WHITE WHITE WHITE ...

Страница 36: ...k in place K Damper Adjustment Make adjustment Let appliance warm up before adjusting Loosen screw using a Phillips head screwdriver Pivot the vertical damper adjustor in 1 4 in 6mm incre ments while observing the flame activity Turning clockwise to open damper less flame height and more blue in flame color Turning counterclockwise to close damper increased flame height and more yellow in flame co...

Страница 37: ... baffle adjustment Ensure that there are no gas leaks Ensure that the glass is sealed and in the proper posi tion Ensure that the flow of combustion and ventilation air is not obstructed front grilles and vent caps B Controls FAN SPEED This knob controls the speed of the blower that pushes the heated air into the room MAIN BURNER This control is used to turn the appliance on and off PILOT IGNITOR ...

Страница 38: ...the appliance May need to remove face front first 5 Push in gas control knob slightly and turn clockwise to the OFF position Do not force 6 Wait five 5 minutes to clear out any gas Smell for gas including near the floor If you smell gas STOP Follow B of the safety information above If you don t smell gas go to the next step 7 Push gas control knob in and turn counterclockwise to the pilot position...

Страница 39: ...tors Smoke and odors may be irritating to sensitive individuals CAUTION Prevent accidental appliance operation when not attended Unplug or remove batteries from remote control if absent or if appliance will not be used for an extended period of time Property damage possible from elevated temperatures CAUTION ISSUE SOLUTIONS Condensation on the glass This is a result of gas combustion and temperatu...

Страница 40: ...rmocouple connection at the gas valve is fully inserted and tight hand tighten plus 1 4 turn Disconnect the thermocouple from the valve place one millivolt lead wire on the tip of the thermocouple and the other meter wire on the thermocouple copper lead Start the pilot and hold the valve knob in If the millivolt reading is less than 15mV replace the thermocouple b Defective valve If the thermocoup...

Страница 41: ...haust gases back into the system Check for proper vent connection at flue collar and all vent joints c Horizontal vent improperly pitched The horizontal vent cap should slope down only enough to prevent any water from entering the appliance d Bad thermopile or thermocouple Replace if necessary e Improper vent cap installation Check for proper installation and freedom from debris or blockage 6 Glas...

Страница 42: ...g or slamming glass Do NOT use abrasive cleaners Use a hard water deposit glass cleaner on white film Do NOT clean glass when hot Turn off appliance after 3 4 hours of operation and ALLOW TO COOL Remove and clean glass assembly Replace glass assembly and operate appliance for additional 12 hours Refer to maintenance instructions Inspect external vent cap regularly Ensure no debris blocks cap Combu...

Страница 43: ...es sary 2 Replace appliance if firebox has been perforated Burner Ignition and Operation 1 Verify burner is properly secured and aligned with pilot or igniter 2 Clean off burner top inspect for plugged ports corrosion or deterioration Replace burner if necessary USE CAUTION WHEN CLEANING HANDLING CERAMIC BURNER 3 Replace ember material with new dime size and shape pieces Do not block ports or obst...

Страница 44: ...reference only For clearances refer to Section 3 Figure 12 1 Appliance Dimensions B C A K L M N O D E F G H I J Location Inches Millimeter Location Inches Millimeter A 27 3 8 695 I 19 3 8 492 B 7 178 J 16 7 8 429 C 27 3 4 705 K 22 1 2 572 D 27 1 2 698 L 3 1 8 79 E 13 3 4 349 M 29 1 2 749 F 8 3 8 213 N 18 457 G 5 1 8 130 O 23 1 8 687 H 22 5 8 575 ...

Страница 45: ...m 17 24 in 432 610mm 11 3 4 in 298mm 5 3 4 in 146mm 6 5 8 in 168mm 6 3 8 in 162mm 6 1 2 in 165mm 9 5 8 in 244mm 6 5 8 in 168mm 6 1 2 in 165mm 6 3 8 in 162mm 9 5 8 in 244mm SLP6M SLP12M SLP12AM SLP45 BK SLP90M 3 3 4 in 95mm 12 17 in 305 432mm 35 3 4 in 908mm 23 3 4 in 603mm 47 3 4 in 1213mm SLP4M SLP48M SLP36M SLP24M SLP6AM 10 9 16 in 269 mm 14 in 356 mm SLP CCS BK Cathedral Ceiling Support Box Bla...

Страница 46: ... 3 48 Pipe Length Galvanized SLP48M 46 DVA 48 B 8 4 A V D 6 4 K B 8 4 P L S k c a l B h t g n e L e p i P 8 4 Adjustable Length 3 6 Black SLP6A BK Adjustable Length 3 6 Galvanized SLP6AM Adjustable Length 3 7 Galvanized 46DVA 08A Adjustable Length 3 7 Black 46DVA 08AB Adjustable Length 3 12 Black SLP12A BK Adjustable Length 3 12 Galvanized SLP12AM Adjustable Length 3 14 5 Galvanized 46DVA 16A Adju...

Страница 47: ... a R e v i t a r o c e D Firestop Spacer Ceiling Firestop SLP FSM 46DVA FS Flex Trap Cap with Firestop SLP FLEX TRAP Flex Trap Cap with Firestop and 30 Flex Pipe SLP FLEXTRAP30B Masonry Chimney Conversion Kit 46DVA KMC S E A V D 6 4 t r o p p u S t e s f f O K B T W P L S k c a l B e l b m i h T l l a W t e s f f O C S A V D 6 4 M C S P L S r a l l o C m r o t S S W A V D 6 4 M S V H P L S d n a B...

Страница 48: ...ase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warranty peri...

Страница 49: ...ED ABOVE WARRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enameled surfaces caused by fingerprints accidents misuse scratches melted items or other extern...

Страница 50: ...this manual with party responsible for use and operation R Quadra Fire Topaz 7009 113 Rev Q 6 14 Printed in U S A Copyright 2014 Quadra Fire a brand of Hearth Home Technologies 7571 215th Street West Lakeville MN 55044 www quadrafire com Please contact your Quadra Fire dealer with any questions or concerns For the location of your nearest Quadra Fire dealer please visit www quadrafire com This pro...

Отзывы: