23
Quadra-Fire • Topaz • 7009-113 Rev. Q • 6/14
6
Gas Information
A. Fuel Conversions
Before making gas connections ensure that the appliance
being installed is compatible with the available gas type.
Any natural or propane gas conversions necessary to meet
the appliance and locality needs must be made by a quali-
fi
ed technician using Hearth & Home Technologies speci
fi
ed
and approved parts.
1. Converting to LP Gas
Figure 6.1
Disconnect power and turn off gas supply if
installed. Remove front, glass, and logs if installed. Loosen
the shutter adjustment nut (located underneath the appli-
ance) with a 7/16 in. wrench. Slide the shutter to the left
(open position).
Figure 6.2
Burner removal:
Remove burner by
fi
rst remov-
ing the two screws indicated and lifting the burner out.
Figure 6.3
Remove the three screws on the front of the burner
support. Set screws aside.
Figure 6.5
Remove the main burner ori
fi
ce using a 5/8 in.
wrench and replace the ori
fi
ce
with the proper size as indi-
cated below for your gas type and venting.
TOOLS REQUIRED:
Power drill (a 90° handle is helpful); #2
Phillips bit; 5/32 in. Allen wrench; 5/8 in. open end wrench.
KIT CONTENTS:
Replacement orifice; replacement pilot
injector; and valve regulator.
Opens Left
Closes Right
Burner Screws
3 screws
Figure 6.4
Slide the burner support to the left to access the
ori
fi
ce.
NOTE: Gas conversions should only be performed
by a qualified service person, and/or where required
by state and local codes, licensed installer/service
technician. In the Commonwealth of Massachusetts,
installation must be performed by a licensed plumber
or gas fitter.
PROPANE
NATURAL GAS
TOPAZ TOP VENT
.073 (49 DMS)
.125 (1/8 in.)
TOPAZ REAR VENT
.063
.113 (33 DMS)