7050-801E

SANTA FE FREESTANDING

Improper installation, adjustment, alteration, service or 

maintenance can cause injury or property damage.

For assistance or additional information, consult a qualified 

installer, service agency or your dealer.

C. Glass Specifications

This appliance is equipped with 5mm ceramic glass. 

Replace glass only with 5mm ceramic glass. Please 

contact your dealer for replacement glass.

D. Electrical Rating

115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 Amps

E. Mobile Home Approved

•  This appliance is approved for mobile home 

installations when not installed in a sleeping room and 

when an outside combustion air inlet is provided.

• 

The structural integrity of the mobile home floor, ceiling, 

and walls must be maintained.

•  The appliance must be properly grounded to the frame 

of the mobile home and use only Listed pellet vent 

Class “L” or “PL” connector pipe.

• 

Outside Air Kit, part OAK-ACC must be installed in a 

mobile home installation.

H. Sleeping Room

When installed in a sleeping room it is recommended that 

3ft of vertical be installed prior to horizontally exiting the 

room and a smoke/CO alarm be installed in the bedroom. 

The size of the room must be at least 50ft³ per 1,000 Btu/hr 

stove input, if the stove exceeds the room size, out air must 

be installed.

I. California - Prop65

WARNING

This product and the fuels used to operate this product (wood), and 

the products of combustion of such fuels, can expose you to 

chemicals including carbon black, which is known to the State of 

California to cause cancer, and carbon monoxide, which is known to 

the State of California to cause birth defects or other reproductive 

harm. For more information go to: WWW.P65Warnings.ca.gov

F. Non-Combustible Materials

Material which will not ignite and burn, composed of any 

combination of the following:

 - Steel

 -

Plaster

 - Brick

 - Iron

 - Concrete

 - Tile

 - Glass

 - Slate

Materials reported as passing 

ASTM E 136, Standard 

Test Method for Behavior of Metals, in a Vertical Tube 

Furnace of 750° C. 

G. Combustible Materials

Material made of/or surfaced with any of the 

following materials:

 - Wood

 -

Compressed Paper

 -

Plant Fibers

 -

Plastic

 -

Plywood/OSB

 -

Sheet Rock (drywall)

Any material that can ignite and burn:

 flame proofed or not, 

plastered or non-plastered.

NOTE:

 Hearth & Home Technologies, manufacturer 

of this appliance, reserves the right to alter 

its products, their specifications and/or price 

without notice.

WARNING

Fire Risk.

Hearth & Home Technologies disclaims any 

responsibility for, and the warranty will be 

voided by, the following actions:

•  Installation and use of any damaged appliance. 

• 

Modification of the appliance.

•  Installation other than as instructed by Hearth & 

Home Technologies.

• 

Installation and/or use of any component part not 

approved by Hearth & Home Technologies.

• 

Operating appliance without fully assembling all 

components.

• 

Operating appliance without legs attached (if supplied 

with appliance).

• 

Do NOT Over fire

 - If appliance or chimney connector 

glows, you are over firing.

Any such action that may cause a fire hazard.

Содержание SANTA FE SANTAFE-C

Страница 1: ...e could result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Do not over fire If ap...

Страница 2: ...6 5 Venting Systems A Through The Wall 17 B Vertical into Existing Class A Chimney 18 C Through The Wall Vertical Exterior 18 D Vertical Interior Typical Installation 18 E Masonry 19 F Alternate Mason...

Страница 3: ...er operation It is against federal regulations to operate this pellet appliance in a manner inconsistent with operating instructions in this manual Emissions Report Number 0061PM077E EPA Certification...

Страница 4: ...f such fuels can expose you to chemicals including carbon black which is known to the State of California to cause cancer and carbon monoxide which is known to the State of California to cause birth d...

Страница 5: ...to installation Installation MUST comply with local regional state and national codes and regulations Consult insurance carrier local building inspector fire officials or authorities having jurisdicti...

Страница 6: ...on to ensure maximum safety and benefit Follow pipe manufacturer instructions for installation and air clearance requirements C Tools And Supplies Needed Tools and building supplies normally required...

Страница 7: ...n and copying this checklist for your file That this checklist remain visible at all times on the appliance until the installation is complete Electrical 120 VAC unswitched power provided to the appli...

Страница 8: ...1mm 28 3 4 in 730mm 9 7 8 in 251mm 12 3 4 in 324mm 3 3 4 in 95mm 6 7 8 in 175mm 2 1 2 in 64mm Figure 8 3 Top View with Top Vent Adapter TPVNT 2 and Offset Adapter 812 3570 Figure 8 2 Top View with Top...

Страница 9: ...set Adapter 812 3570 18 1 4 in 464mm 21 in 533mm 16 3 4 in 427mm 28 3 4 in 730mm 26 7 8 in 653mm Figure 9 2 Side View with Top Vent Adapter TPVNT 2 and Offset Adapter 811 0720 Figure 9 4 Side View wit...

Страница 10: ...rner Installation Inches Millimeters G Side Wall to Appliance Corner 2 51 H Side Wall to Flue Pipe 3 76 Installations with TPVNT 2 Top Vent Adapter w Heat Shield Clean out TPVNT 6 Top Vent Adapter wit...

Страница 11: ...area to the wall thimble 152MM FUEL DOOR OPENING USA INSTALLATIONS A non combustible floor protection is recommended extending beneath the flue pipe when installed with horizontal venting or under the...

Страница 12: ...um Inches Millimeters Inches Millimeters A Height 43 1092 n a n a B Width 38 965 n a n a C Depth n a n a 36 914 D To Side Wall 6 152 n a n a Figure 12 2 NOTE Illustrations reflect typical installation...

Страница 13: ...ences and protruding parts of the structure P 12 in Clearance above roof line for vertical terminations All minimum clearances are listed with an Outside Air Kit OAK installed unless otherwise noted i...

Страница 14: ...ance but consideration must be given to the total house demand House demand may consume the air needed for the appliance It may be necessary to add additional ventilation to the space in which the pel...

Страница 15: ...vertically or horizontally NOTE Follow venting manufacturers recommendations for sealing pipe joints NOTICE Hearth Home Technologies assumes no responsibility for the improper performance of the chimn...

Страница 16: ...t intended to represent any specific fuel type G Pipe Selection Chart The chart will help you in determining proper venting size according to the equivalent feet of pipe calculated previously and the...

Страница 17: ...or mobile home installations Must use 3 or 4 inch 76 102mm L or PL Listed pellet venting or Listed double wall pipe and a Quadra Fire Outside Air Kit in mobile homes NOTE In Canada where passage throu...

Страница 18: ...76mm Minimum Cleanout Cover 12 in 305mm Minimum Ceiling Support 6 in 152mm Flue Connector 6 in 152mm Class A Chimney Connector Adapter 3 in to 6 in 76 152mm Top Vent Kit All three installations are a...

Страница 19: ...oncrete Cap 1 in 25mm Clearance with Firestop 6 in 152mm Minimum Non combustible Hearth Pad Airtight Clean out Door Sheathing 2 in 51mm Minimum Flashing 1 in 25mm Clearance 1 in 25mm Clearance with Fi...

Страница 20: ...ps head screwdriver wire cutters hole saw or jig saw 1 Measure distance from floor to air vent opening in appliance and mark location on wall Use a saw to cut opening in wall Cut a 2 1 2 to 3 inch 64...

Страница 21: ...e silicone on the 3 inch 76mm exhaust outlet Do not put silicone inside of pipe Figure 21 1 2 Slide the adapter onto the rear exhaust outlet and adjust the assembly to the appropriate position 3 Insta...

Страница 22: ...see Figure 22 4 TERMINAL BLOCK CENTER 2 SCREWS FOR THERMOSTAT WIRES POWER OUTLET Figure 22 1 Figure 22 2 Figure 22 3 1 Separate the body of the thermostat from the mounting plate by gently pulling the...

Страница 23: ...PART NUMBER 811 0872 Spark Arestor Cap Roof Flashing Storm Collar Joist Shield Firestop Double Wall Connector Pipe Figure 23 1 WARNING Products of combustion generate carbon monoxide and different fue...

Страница 24: ...24 09 20 7050 801E SANTA FE FREESTANDING 8 Reference Materials A Service and Maintenance Log Date of Service Performed By Description of Service...

Страница 25: ...25 09 20 7050 801E SANTA FE FREESTANDING Date of Service Performed By Description of Service...

Страница 26: ...apter 90 Cleanout TPVNT 6 Vent Adapter Rear 811 0620 Damper 3 inch PEL DAMP3 Y Damper 4 inch PEL DAMP4 Additional service part numbers appear on following page IMPORTANT THIS IS DATED INFORMATION Part...

Страница 27: ...of 24 226 0130 24 Y Pin 3 16 x 1 2 7000 229 Rivet Iron 1 4 X 1 1 4 Pkg of 25 229 0090 25 Screw 8 32 X 1 4 Qty 40 225 0240 40 Screw Hwh 1 4 20 X 3 4 Ns Pkg of 25 220 0080 25 Y Screw Flat Head Screw 1 4...

Страница 28: ...maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance We...

Отзывы: