R
May 12, 2014
7050-128G
Page 19
Santa Fe Pellet Stove
7
Appliance Set-Up
A. Outside Air Kit Instructions
Flex Hose
Hose Clamp
Collar Assembly
Trim Ring
Termination
Cap Assembly
Hose Clamp
Air Intake Channel
(Discard)
Parts Included in Kit:
1 piece of 2 inch x 3 foot fl ex hose,
2 hose clamps, 1 air intake channel1 collar assembly, 1 ter-
mination cap assembly, 1 trim ring, 12 screws. (Discard air
channel it is not need for this appliance).
1. Measure distance from fl oor to air vent opening in stove
and mark location on wall.
Use saw to cut opening in wall. Cut a 2-1/2 to 3 inch
(64-76mm) opening on inside wall and a 3 to 3-1/2 inch
(76-89mm) opening on outside of house.
2. Remove cover plate and then install the collar assem-
bly.
3. Use hose clamp to secure fl ex pipe to collar assembly.
4. Slide trim ring over fl ex pipe and run pipe through wall.
5. Attach hose to outside termination cap with second hose
clamp.
6. Secure termination cap to outside surface.
7. Secure trim ring to interior wall.
Tools Needed:
Phillips head screwdriver; wire cutters; hole
saw or jig saw.
CAUTION
Never draw outside combustion air from:
• Wall,
fl oor or ceiling cavity
• Enclosed space such as an attic or garage
Figure 19.2
Termination Cap
Hose Clamp
Trim Ring
Flex Hose
Collar
Assembly
Figure 19.1