7019-230J
October 23, 2018
17
SANTA FE PELLET INSERT
CAUTION
Never draw outside combustion air from:
•
Wall, floor or ceiling cavity
• Enclosed space such as an attic or garage
Optional Outside Air through Rear
Wall (Horizontal)
NOTE; Use metal plate around
exhaust vent pipe and seal all
edges with non-flammable insu-
lation such as fiberglass, mineral
wool or ceramic.
Do not use high temperature
caulking materials to seal any
edge to prevent furture service-
ability.
Figure 17.1
Fire Risk.
Inspection of Chimney:
•
Masonry chimney must be in good condition.
•
Meets minimum standard of NFPA 211
•
Factory-built chimney must be a minimum 6
inch (152mm) UL103 HT.
WARNING
5
Venting Systems
A. Full Reline With Outside Air - Horizontal
NOTE:
In Canada, where passage through a wall or
partition of combustible construction is desired,
the installation shall conform to
CAN/CSA-B365
.
NOTE:
•
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
•
Illustrations/diagrams are not drawn to scale.
•
Actual installation may vary due to individual design
preference.