Lifetime Warranty

LIMITED LIFETIME WARRANTY

The Hearth & Home Technologies limited Lifetime Warranty guarantees that the following components will work as
designed for the lifetime of the stove or Hearth & Home Technologies will repair or replace them.  These items include but
are not limited to steel and cast iron components, all gas burners, gas logs, combustion chambers, heat exchanger
systems, stainless steel firebox components, plating, doors, glass damaged by thermal breakage, steel baffle supports,
steel and ceramic baffles and manifold tubes. Labor is for the first five years.

THREE YEAR WARRANTY

Our EZ Clean firepots are covered under Hearth & Home Technologies three-year warranty program.  Labor is for 3 years.

TWO YEAR WARRANTY

All electrical components such as but not limited to blowers, wiring, vacuum switches, speed controls, control boxes,
thermodisc switches, pilot assembly, gas valves, thermostats and remotes are covered under Hearth & Home Technologies
two-year warranty program.

ONE YEAR WARRANTY

Porcelain finishes are warranted against manufacturer defects for one year.  Labor to repair or replace these parts is
covered for one year, reimbursed per our warranty service fee schedule.

CONDITIONS

This warranty is nontransferable and is made to the original retail purchaser only provided that the purchase was made
through an authorized dealer of Hearth & Home Technologies It must be installed and operated at all times in accordance
with the Installation and Operating Instructions furnished with this product, as well as any applicable local and national
codes.  Any alteration, willful abuse, accident, or misuse of the product shall nullify this warranty.

Labor to repair or replace items covered under the limited Lifetime Warranty will be covered for the first five years per our
warranty service fee reimbursement schedule.  Parts covered under the limited Lifetime Warranty will be covered for the
lifetime of the appliance up to a maximum of ten (10) years after Hearth & Home Technologies discontinues the model and
two (2) years for optional accessories.  Adjustments, regular maintenance, cleaning and temporary repairs do not qualify
for a service call fee and will not be covered.  The replacement of consumer replaceable items and installation of upgraded
component parts do not quality for a service call fee, and will not be covered.

This limited Lifetime Warranty does not extend to or include surface finish on the appliance, door gasketing, glass
gasketing, firebrick, kaowool or other ceramic insulating materials.  It does not cover installation or operational-related
problems such as overfiring, use of corrosive driftwood, downdrafts or spillage caused by environmental conditions,
nearby trees, buildings, hilltops, mountains, inadequate venting or ventilation, excessive offsets, or negative air pressures
caused by mechanical systems such as furnaces, fans, clothes dryers, etc.

Any installation, construction, transportation, or other related costs or expenses arising from defective part(s), repair,
replacement, etc., will not be covered by this warranty, nor will Hearth & Home Technologies assume responsibility for
them.  Further, Hearth & Home Technologies will not be responsible for any incidental, indirect, or consequential damages,
except as results in damage to the interior or exterior of the building in which this appliance is installed.  This limited
Lifetime Warranty does not apply to the venting components, hearth components or other accessories used in conjunction
with the installation of this product not manufactured by Hearth & Home Technologies

This warranty is void if the stove has been overfired or operated in atmospheres contaminated by chlorine, fluorine, or
other damaging chemicals, the stove is subjected to prolonged periods of dampness or condensation, or there is any
damage to the stove or other components due to water or weather damage which is the result of, but not limited to,
improper chimney or venting installation.  Hearth & Home Technologies may, at its discretion, fully
discharge all obligations with respect to this warranty by either repairing or replacing the unit, or
refunding the wholesale price of the defective part(s).

This limited Lifetime Warranty is effective on all appliances sold after May 1, 2002 and supersedes
any and all warranties currently in existence.

Содержание QV-ST

Страница 1: ...FOR FUTURE REFERENCE 1 This appliance may be installed in an af termarket permanentlylocated manufac tured mobile home wherenotprohibited by local codes 2 This appliance is only for use with the type...

Страница 2: ...DERSTAND all instructions carefully before starting the installation FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty Prior to the firs...

Страница 3: ...onents 22 C Vent Termination 25 Step 4 Positioning Leveling and Securing the Fireplace 27 Step 5 The Gas Control Systems 28 Step 6 The Gas Supply Line 28 Step 7 Gas Pressure Requirements 28 Step 8 Wir...

Страница 4: ...LP Exploded Parts Diagram Vue clat e des pi ces Part number list on following page La liste des num ros de pi ce se trouve la page suivante Service Parts 1 2 3 4 10 6 7 9 8 6 7 9 8 12 11 5 Log Set As...

Страница 5: ...S Orifice de br leur GN 32DMS 573 800 Burner Orifice LP 1 8mm Orifice de br leur PL 1 8mm 501 801 Junction Box Bo tier de d rivation 100 250A Piezo Ignitor Allumage Pi zo 291 513 Thermopile Thermopile...

Страница 6: ...LP Exploded Parts Diagram Vue clat e des pi ces Part number list on following page La liste des num ros de pi ce se trouve la page suivante Service Parts 6 7 9 8 6 7 9 8 1 2 3 4 10 11 11 5 Log Set As...

Страница 7: ...3 800 Burner Orifice LP 1 8mm Orifice de br leur PL 1 8mm 501 801 Junction Box Bo tier de d rivation 100 250A Piezo Ignitor Allumage Pi zo 291 513 Thermopile Thermopile 060 512 Thermocouple Thermocoup...

Страница 8: ...odes or in the absence of local codes with the National Electric Code ANSI NFPA No 70 in the United States or to the CSA C22 1 Canadian Electric Code in Canada These models may be installed in a bedro...

Страница 9: ...instructions will void the own er s warranty and may present a fire hazard The Quadra Fire Warranty will be voided by and Hearth Home Technologies disclaims any responsibility for the following actio...

Страница 10: ...LLE SIDE GLASS DOOR END GLASS DOOR TOP STANDOFFS TOP GRILLE TOP VENT COLLARS FRONT RIGHT SIDE LEFT SIDE 13 331mm 24 1 4 616mm 12 1 8 308mm VENT COLLARS 42 3 4 1086mm 28 7 8 735mm ELECTRICAL ACCESS 2 1...

Страница 11: ...RICAL ACCESS GAS LINE ACCESS GAS CONTROLS LABELS BOTTOM GRILLE TOP GRILLE TOP STANDOFFS GLASS DOOR 45 1143mm 13 330mm 12 1 8 308mm VENT COLLARS 24 1 4 616mm 28 7 8 733mm 2 1 2 64mm GAS LINE ACCESS 4 1...

Страница 12: ...t before or after the fireplace is set in place Framing should be positioned to accommo date wall coverings and fireplace facing material The dia gram below shows framing reference dimensions CAUTION...

Страница 13: ...4 41 1 2 23 1 4 45 29 7 8 QV PIER 43 1 4 44 41 1 2 23 1 4 45 29 7 8 Figure 4 Framing Dimensions NOTE DIMENSIONSSHOWNININCHES Shows center of 12 x 12 vent framing holes for top and rear venting The ce...

Страница 14: ...inch inner pipe 8 5 8 inch outer pipe DV 36D 5 3 4 146mm 8 3 4 222mm 11 3 4 298mm DV 12D DV 09D DV 06D DV 48D DV 90D 7 3 8 187mm 6 5 32 156mm 11 5 8 295mm 11 15 16 303mm 5 7 8 149mm 8 5 8 220mm 8 1 2...

Страница 15: ...nd the venting configuration used Identifying Vent Components The vent systems installed on this gas fireplace may in clude one two or three 90 elbow assemblies The rela tionships of vertical rise to...

Страница 16: ...16 Figure 7 Straight Up Vertical Venting STRAIGHT UP VERTICAL VENTING V FT 40 MAX 12 4 M STRAIGHT OUT HORIZONTAL VENTING H Max Run 24 610 mm Figure 8 Straight Out Horizontal Venting H V CAP...

Страница 17: ...2 MAX 3 6m 5 MIN 1 5m 15 MAX 4 5m 6 MIN 1 86m 17 MAX 5 1m H 17 MAX 5 1m V H 37 MAX 11 3m Figure 10 Venting with One 90 Elbow V H 1 MIN 305mm 2 MAX 610mm 2 MIN 610mm 4 MAX 1 22m 3 MIN 914mm 6 MAX 1 86m...

Страница 18: ...MIN 1 22m 12 MAX 3 6m 5 MIN 1 5m 15 MAX 4 5m 6 MIN 1 86m 17 MAX 5 1m 17 MAX 5 1m V H 37 MAX 11 3m Figure 11 Venting with Two 90 Elbows VENTING WITH TWO 2 90 ELBOWS V FT H FT 1 MIN 305mm 3 MAX 914m 2 M...

Страница 19: ...X 2 7 m 4 MIN 1 22 m 8 MAX 2 48 m 12 MAX 3 6 m 8 MAX 2 48 m 17 MAX 5 1 m V H H1 37 MAX 11 3m Figure 12 Venting with Two 90 Elbows Figure 13 Venting with Two 90 Elbows VENTING WITH TWO 2 90o ELBOWS V F...

Страница 20: ...m 4 MIN 1 22 m 8 MAX 2 48 m 15 MAX 4 5 m 8 MAX 2 48 m 17 MAX 5 1 m V H H1 H2 37 MAX 11 3m VENTING WITH THREE 3 90 ELBOWS V H H H1 H2 1 MIN 305 mm 2 MAX 610 mm 3 MAX 914mm 2 MIN 610 mm 4 MAX 1 22 m 6 M...

Страница 21: ...MIN 1 22m 12 MAX 3 6m 17 MAX 5 1m NOTE H H1 17 MAX 5 1m V V1 H H1 37 MAX 11 3m VENTING WITH THREE 3 90 ELBOWS V FT H H1 FT 1 MIN 305mm 3 MAX 914m 2 MIN 610mm 6 MAX 1 86m 3 MIN 914mm 9 MAX 2 7m 4 MIN...

Страница 22: ...16 Follow the vent configuration tables accordingly Remove the insulation from the REAR five inch flue pull the heat shield out from outside of the firebox WARNING THE TOP HEAT SHIELD INSIDE THE FIREB...

Страница 23: ...e firestops Figure 20 12 x 12 Hole and Vent Pipe Figure 21 Heat Shield Interior Exterior Firestops VENT PIPE 1 25 4 mm 12 305mm 12 305mm TRIM HEAT SHIELD IF TOO LONG ADD TO SHIELD IF TOO SHORT EXTERIO...

Страница 24: ...iling using the centerpoint previously marked Frame the hole with framing lumber the same size as the ceiling joists Figure 23 Ceiling Firestop Ceiling Side If the area above the ceiling is NOT an att...

Страница 25: ...ermination cap to its final exterior position on the building WARNING THE TERMINATION CAP MUST BE POSITIONED SO THAT THE ARROW IS POINTING UP For trapezoidal cap termination kits Using screws secure t...

Страница 26: ...ne side and with an overhang are permitted with the dimensions specified for vinyl or non vinyl siding and soffits 1 There must be 3 feet minimum between termination caps 2 All mechanical air intakes...

Страница 27: ...of the building Roof Pitch H min ft flat to 6 12 1 0 6 12 to 7 12 1 25 over 7 12 to 8 12 1 5 over 8 12 to 9 12 2 0 over 9 12 to 10 12 2 5 over 10 12 to 11 12 3 25 over 11 12 to 12 12 4 0 over 12 12 t...

Страница 28: ...he shut off valve When attaching the pipe support the control so that the lines are not bent or torn Step 7 Gas Pressure Requirements Pressure requirements for Hearth Home Technolo gies gas fireplaces...

Страница 29: ...anently installed Wall Switch Position the wall switch in the desired position on a wall Run a maximum of 25 feet 7 8 m or less length of 18 A W G minimum wire and connect it to the fireplace ON OFF s...

Страница 30: ...D A 300 F MINIMUM SEALANT MATE RIAL MUST BE USED THESE JOINTS ARE NOT RE QUIRED TO BE SEALED ONLY NON COMBUSTIBLE MATERIAL USING 300 F MINIMUM ADHESIVE IF NEEDED CAN BE APPLIED AS FACING TO THE FIRE P...

Страница 31: ...lace dime size pieces of ember material about 1 2 inch apart near port holes in burner top Do NOT press em bers into burner ports Cover the top of the burner with a single layer of ember material For...

Страница 32: ...the control in the PILOT position turn the control knob counter clockwise to the PILOT position 6 To light the pilot press the control knob and then press the red or black piezo button once every sec...

Страница 33: ...in the gas supply lines When first lighting the fireplace it will take a few minutes for the lines to purge themselves of this air Once the purging is complete the fireplace will light and will operat...

Страница 34: ...ntrol compartment fireplace logs and burner areas surrounding the logs Checking Flame Patterns Flame Height Frequency Periodically By Qualified service technician Home owner Task Make a visual check o...

Страница 35: ...he pilot and hold the valve knob in If the millivolt reading is less than 15mV replace the thermocouple b Defective valve If the thermocouple is producing more than 15 millivolts replace faulty valve...

Страница 36: ...downwards lope is 1 4 inch d Glass too loose and air tight packet leaks in corners after usage Tighten the corner e Bad thermopile or thermocouple Replace if necessary f Improper vent cap installation...

Страница 37: ...accessories Adjustments regular maintenance cleaning and temporary repairs do not qualify for a service call fee and will not be covered The replacement of consumer replaceable items and installation...

Отзывы: