background image

18

02/22

8105-803B

A. Through The Wall

Horizontal termination cap must be a minimum of 6 

inches. (152mm) from the wall. Approved for mobile home 

installations. Must use 3 or 4 inch (76-102mm) “L” or “PL” 

listed pellet venting or Listed double wall pipe and an 

authorized Outside Air Kit in mobile homes.

Wall 

Thimble

Illustration shows venting going in both directions. 

Choose which one is best for your installation.

3 in. (76mm) 

Minimum

3 in. 

(76mm) 

Minimum

6 in (152mm) Minimum

6 in 

(152mm) 

Minimum 

Figure 18.2

 - 45 Degree

NOTE: 

In  Canada,  where  passage  through  a  wall  or 

partition of combustible construction is desired, the 

installation shall conform to 

CAN/CSA-B365

Figure 18.1

 - Straight Out

6 in.  

(152mm) 

Minimum

Non-combustible Hearth Pad

Wall 

Thimble

Horizontal 

Termination 

Cap

3 in. 

(76mm) 

Minimum 

6 in. 

(152mm) 

Minimum 

from glass

NOTICE:

 Please note that while the minimum clearance 

for the termination cap is 6 inches (152mm) there is the 

possibility of soot build-up around the termination area. 

If this occurs we suggest to move the termination further 

away from the house to prevent it.

Venting Systems 

We  strongly  recommend  that  you  DO  NOT 

DOWNWARD VENT.

The following may occur:

•  The appliance will not vent properly

•  Smoke spillage in the house

•  Excessive sooting

CAUTION

Содержание OUTFITTER-II

Страница 1: ...iquids in the vicinity of this or any other appliance Do not over fire If appliance or chimney connector glows you are over firing Over firing will void your warranty Comply with all minimum clearance...

Страница 2: ...nstallation Location Considerations 5 B Thermostat Wall Control Location 6 C Tools And Supplies Needed 6 D Inspect Appliance and Components 6 E Removal of Appliance from Pallet 6 F Install Checklist 7...

Страница 3: ...iency 87 5 HHV Tested Efficiency 81 9 EPA BTU Output 9 605 to 40 667 per hr BTU Input 11 676 to 49 207 per hr Vent Size 3 or 4 Type L or PL Hopper Capacity 130 lbs Fuel Premium Wood Pellets Weighted a...

Страница 4: ...Stove Composition These pellet burning stoves are made of steel cast iron or a combination of both with a ceramic viewing glass These stoves incorporate a self feeding system including a fuel storage...

Страница 5: ...nstallation MUST comply with local regional state and national codes and regulations Consult insurance carrier local building inspector fire officials or authorities having jurisdiction over restricti...

Страница 6: ...faces have been wiped clean with a soft cloth if applicable Read all the instructions before starting the installation Follow these instructions carefully during the installation to ensure maximum saf...

Страница 7: ...ng this checklist for your file That this checklist remain visible at all times on the appliance until the installation is complete Electrical 120 VAC unswitched power provided to the appliance Check...

Страница 8: ...A Appliance Dimensions Figure 8 1 Top View 2 1 2 64mm 4 1 2 114mm Figure 8 3 Front View 24 1 2 622mm 36 1 2 927mm Figure 8 2 Side View 22 7 8 581mm 9 1 2 241mm FLUE 8 1 4 210mm AIR INLET 3 3 Dimensio...

Страница 9: ...76mm Figure 9 2 Side View w Top Vent Adapter TPVNT 7 28 711mm Figure 9 3 Top View w Top Vent Adapter TPVNT 7 3 to 4 inch Offset Adapter 811 0720 12 1 4 311mm 3 1 4 83mm Figure 9 4 Side View w Top Ven...

Страница 10: ...Adapter 812 3570 Figure 10 2 Side View w Top Vent Adapter TPVNT 7 3 to 6 inch Offset Adapter 812 3570 12 1 4 311mm 4 1 4 108mm 27 7 8 708mm 29 7 8 760mm Figure 10 3 Top View w Top Vent Adapter TPVNT...

Страница 11: ...Wall Inches Millimeters A Back Wall to Appliance 3 76 B Side Wall to Appliance 9 229 Corner Installation Inches Millimeters C Walls to Appliance 3 76 Table 11 1 Vertical Installation Inches Millimete...

Страница 12: ...tal venting or under the Top Vent Adapter with vertical installation CANADA INSTALLATIONS A non combustible floor protection extending beneath the flue pipe is required with horizontal venting or unde...

Страница 13: ...s A Height 52 1321 n a n a B Width 42 1 2 1080 n a n a C Depth n a n a 25 3 4 654 All minimums listed are to a combustible surface NOTE Illustrations reflect typical installations and are FOR DESIGN P...

Страница 14: ...12 in Clearance above roof line for vertical terminations All minimum clearances are listed with an Outside Air Kit OAK installed unless otherwise noted in table below 24 in Above grass top of plants...

Страница 15: ...emand may consume the air needed for the appliance It may be necessary to add additional ventilation to the space in which the pellet appliance is located Consult with your local HVAC professional to...

Страница 16: ...Install through the warm airspace enclosed by the building envelope This helps to produce more draft especially during lighting and die down of the fire Considerations for successful draft include Pre...

Страница 17: ...eft side of the chart 2 Move to the right horizontally on the chart until you reach your altitude above sea level 3 If you fall below the diagonal line 3 or 4 inch 76 to 102mm pipe may be used 4 If it...

Страница 18: ...ssage through a wall or partition of combustible construction is desired the installation shall conform to CAN CSA B365 Figure 18 1 Straight Out 6 in 152mm Minimum Non combustible Hearth Pad Wall Thim...

Страница 19: ...tructions for all reduced air clearances installations B Vertical into Existing Class A Chimney Non combustible Hearth Pad Clean out Cover Tee Wall Thimble Support Bracket Every 60 in 1 5m 12 in 305mm...

Страница 20: ...with Airspace Concrete Cap Figure 20 1 Non combustible Hearth Pad Airtight Clean Out Door Clean Out cover Sheathing 3 in 76mm Minimum 1 in 25mm Clearance Flashing Fireclay flue Liner with Airspace Con...

Страница 21: ...utside of house 3 Use hose clamp to secure flex pipe to collar assembly 4 Slide trim ring over flex pipe and run pipe through wall 5 Attach flex pipe to outside termination cap with second hose clamp...

Страница 22: ...e 2 screws Figure 22 1 5 Install the vent pipe into the top vent adapter 6 To clean the top vent adapter open the clean out cover Figure 22 1 C Rear Vent Adapter Installations 1 Put a layer of high te...

Страница 23: ...direct sunlight above a lamp television radiator a wall next to a window or direct heat from the appliance Avoid damp environments as this can lead to corrosion that may shorten thermostat life If pa...

Страница 24: ...Collar Joist Shield Firestop Double Wall Connector Pipe Figure 24 1 7 7 Mobile Home Installation Products of combustion generate carbon monoxide and different fuels generate different levels Carbon m...

Страница 25: ...25 02 22 8105 803B A Service Maintenance Log Date of Service Performed By Description of Service 8 8 Reference Materials...

Страница 26: ...maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance We...

Отзывы: