background image

October 3, 2017  

 

  

 

 

7036-188J 

 

 

 

         

                  23

MT VERNON AE INSERT

Service Parts

R

MT VERNON INSERT-AE

Beginning Manufacturing Date: Sept. 2006 

Ending Manufacturing Date: Active

IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. 

Hearth and 

Home Technologies does not sell directly to consumers

. Provide model number and serial number when 

requesting service parts from your dealer or distributor.

Stocked 

at Depot

ITEM

DESCRIPTION

COMMENTS

PART NUMBER

12 Volt Power Cord

12VCORD-AE

Y

Brackets for Trim Insulation

SRV7022-503G

Damper, 3 Inch - Tall Vertical Installs Only

PEL-DAMP3

Y

Damper, 4 Inch - Tall Vertical Installs Only

PEL-DAMP4

Firescreen

No Longer Available

SCR-7005

Hearth Support

No Longer Available

ZCSPT-MVI

Log Set (2 Pc)

Sold as set only

LOGS-60-AE-B

Y

Outside Air Kit

OAK-3

Surround, Std, Panel, For Cast Trim

SP-MTVS-CST

Component Pack

7036-041

Surround, Std, Panel, w/Gold Trim

No Longer Available

SP-MTVS-GD

Component Pack

7036-042

Trim, Panel Set, Gold

SRV250-4660

Surround, Std, Panel w/Nickel Black Trim

SP-MTVS-NB

Component Pack

7036-042

Trim Set, Black Nickel

7019-027

Trim Cast

Matte Black

811-0930

Sienna Bronze

TR-CAST-CSB

No longer available

TR-CAST-CWL

Mahogany

811-0960

Footer, Left

Matte Black

414-7090MBK

Sienna Bronze

414-7090CSB

No longer available

414-7090CWL

Mahogany

414-7090PMH

Footer, Right

Matte Black

414-7100MBK

Sienna Bronze

414-7100CSB

No longer available

414-7100CWL

Mahogany

414-7100PMH

Header

Matte Black

414-7110MBK

Sienna Bronze

414-7110CSB

No longer available

414-7110CWL

Mahogany

414-7110PMH

Trim Leg, Left

Matte Black

414-7120MBK

Sienna Bronze

414-7120CSB

No longer available

414-7120CWL

Mahogany

414-7120PMH

Trim Leg, Right

Matte Black

414-7130MBK

Sienna Bronze

414-7130CSB

No longer available

414-7130CWL

Mahogany

414-7130PMH

Accessory List

Содержание MTVERNINSAE-CSB

Страница 1: ...soline or other flam mable vapors and liquids in the vicinity of this or any other appliance Do not over fire If appliance or chimney connector glows you are over firing Over firing will void your warranty Comply with all minimum clearances to combustibles as specified Failure to comply may cause house fire WARNING CAUTION Tested and approved for wood pellets shelled field corn wheat and black oil...

Страница 2: ...14 E Chimney and Exhaust Connection 14 F Equivalent Feet of Pipe 15 G Pipe Selection Chart 15 5 Venting Systems 16 A Full Reline With Outside Air Horizontal 16 B Full Reline With Outside Air Vertical 17 6 Appliance Set Up 18 A Leveling System 18 B Outside Air Kit Instructions 18 C Hearth Support 19 D Removal of Cast Sides 19 E Surround and Trim Set Cast 20 F Surround Trim Set Basic 20 G Optional L...

Страница 3: ... appliance Modification of the appliance Installation other than as instructed by Hearth Home Technologies Installation and or use of any component part not approved by Hearth Home Technologies Operating appliance without fully assembling all components Operating appliance without legs attached if supplied with appliance Do NOT Over fire If appliance or chimney connector glows you are over firing ...

Страница 4: ...st be given to Safety convenience traffic flow Placement of the chimney and chimney connector and to minimize the use of chimney offsets Place the appliance where there will be a clear passage for a Listed chimney through the ceiling and roof vertical or through exterior wall horizontal Installing the required outside air kit will affect the location of the vent termination When locating vent and ...

Страница 5: ...trol is an integral part of the appliance No other wall control or thermostat can be substituted D Inspect Appliance and Components Open the appliance and remove all the parts and articles packed inside the Component Pack Inspect all the parts and glass for shipping damage Report to your dealer any parts damaged in shipment All labels have been removed from the glass door Plated surfaces have been...

Страница 6: ...to the party responsible for use and operation ATTENTION INSTALLER Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjunction with not instead of the instructions contained in this installation manual Customer __________________________________________________________________________ Date Installed ________________________________________________...

Страница 7: ...und Set 36 5 8 932 15 380 13 1 8 333 12 7 8 327 32 814 23 7 8 606 3 5 8 92 3 5 8 92 23 7 8 606 32 813 13 330 15 1 8 384 13 330 36 3 4 932 45 1143 34 1 2 876 50 1270 33 838 29 3 4 756 23 7 8 605 11 3 4 299 26 7 8 683 17 1 4 437 11 7 8 302 26 7 8 683 29 3 4 756 17 1 4 437 23 7 8 605 Figure 7 3 Side View with Cast Panel Set Figure 7 6 Side View with Basic Surround Set 3 Dimensions and Clearances A Ap...

Страница 8: ...learances to Combustibles UL and ULC Fire Risk Comply with all minimum clearances to combusti bles as specified WARNING Failure to comply may cause house fire Figure 8 1 Built in Appliance Framing Dimensions 26 7 8 in 683 mm 22 1 2 in top vent 572 mm 17 3 4 in rear vent 451 mm 36 in 914 mm If interior of chase will be drywalled add the thickness to this measurement Top vent depth dimension assumes...

Страница 9: ...1010mm Figure 9 2 HEARTH EXTENSION No thermal protection required Ember protection only If mantel depth is 10 inches or less than the height from the hearth to the bottom of the mantel is 39 3 4 inches Minimum Opening Dimensions Inches Millimeters A Height 24 1 8 613 B Front Width Steel Panel Set 32 1 4 819 Front Width Cast Panel Set 32 1 4 819 C Back Width 24 1 8 613 D Depth Steel Panel Set 15 3 ...

Страница 10: ... BURNING FIREPLACE 250 2061 Heath Home Technologies 250 2061 5 5 in width x 2 in height NON ANOD ALUM BLACK LETTERS ON SILVER with 1 8 in holes on both sides Black letters Figure 10 1 If the hearth extension is lower than the fireplace opening the portion of the insert extending onto the hearth must be supported The following is only one example as there are many differ ent models of factory built...

Страница 11: ...chimney cap must be re installed after installing the approved chimney liner meeting type UL 103 HT requirements 2100 F per UL 1777 If the chimney is not listed as meeting HT requirements or if the factory built fireplace was tested prior to 1998 a full height listed chimney liner must be installed from the appliance flue collar to the chimney top The liner must be securely attached to the insert ...

Страница 12: ...ces and protruding parts of the structure P 12 in Clearance above roof line for vertical terminations All minimum clearances are listed with an Outside Air Kit OAK installed unless otherwise noted in table below 24 in Above grass top of plants wood or any other com bustible 12 in 36 in no OAK Clearance from any forced air intake of other appli ance 12 in Clearance horizontally from combustible wal...

Страница 13: ...e space in which the pellet appliance is located Consult with your local HVAC professional to determine the ventilation demands for your house Vent Configurations When installing a pellet appliance with a horizontal vent con figuration the frequency of power outages should be consid ered Power outages during operation will cause the appliance to immediately turn off and may create conditions where...

Страница 14: ...himney NOTICE HEARTH Home Technologies assumes no responsibility for the improper performance of the chimney system caused by Inadequate draft due to environmental conditions Down drafts Tight sealing construction of the structure Mechanical exhausting devices E Chimney and Exhaust Connection 1 Chimney Connector Use 3 or 4 inch 76 102mm diameter type L or PL venting system It can be vented vertica...

Страница 15: ...1829m you may use 3 or 4 inch 76 to 102mm diameter type L or PL vent G Pipe Selection Chart The chart will help you in determining proper venting size according to the equivalent feet of pipe calculated previously and the altitude above sea level of this installation Figure 15 2 a Locate the calculated equivalent feet of pipe on the vertical left side of the chart b Move to the right horizontally ...

Страница 16: ...draw outside combustion air from Wall floor or ceiling cavity Enclosed space such as an attic or garage NOTE Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY Illustrations diagrams are not drawn to scale Actual installation may vary due to individual design preference A Full Reline With Outside Air Horizontal Outside Air through Rear Wall Horizontal NOTE Use metal plate...

Страница 17: ...side Air Vertical Figure 17 1 Outside Air Termination at Chimney Top Vertical 305mm min below 305mm min above NOTE Use metal plate around exhaust vent pipe and seal all edges with non flammable insula tion such as fiberglass mineral wool or ceramic Do not use high temperature caulk ing materials to seal any edge to prevent furture serviceability NOTE In Canada this fireplace insert must be install...

Страница 18: ...ng on outside of house 3 Use wire ties to secure flex pipe to collar assembly 4 Slide trim ring over flex pipe and run pipe through wall 5 Attach flex pipe not included to outside termination cap with second wire tie 6 Secure termination cap to outside surface 7 Secure trim ring to interior wall CAUTION Never draw outside combustion air from Wall floor or ceiling cavity Enclosed space such as an a...

Страница 19: ...d then release the latch The latch hooks onto a bracket to hold the side in place Bend tabs down Shipped flat from the factory Figure 19 2 9 attachment holes 3 on each side and 3 in the front Figure 19 3 Included in Kit 1 bottom 1 trim front 2 trim sides 2 trim extensions Tools Needed Phillips head screw driver measuring tape gloves 1 Remove contents from box and lay on protective surface to avoid...

Страница 20: ...d tabs down Included in Surround Kit 2 side panels left and right 1 panel top 1 fastener package Included in Cast Trim Kit 2 cast trim legs left and right 1 cast trim header 2 cast trim footers left and right 1 fastener package Tools Needed Powered Phillips head screw driver 1 Remove contents from box being careful not to scratch or damage the cast trim pieces 2 Lay the surround set face down on p...

Страница 21: ...l Control Thermostat Installation 1 When mounting the wall control thermostat on the wall be sure to follow your wall control s installation instruc tions carefully NOTE The wall control thermostat should be mount ed on an inside wall and not in direct line with the appliance convection air NOTE If the wall control thermostat is located too close to the appliance you may need to set the temperatur...

Страница 22: ...80 Part 24 NEVER INSTALL IN A SLEEPING ROOM WARNING Spark Arrestor Cap Roof Flashing Storm Collar Joist Shield Firestop Approved Class L or PL Pellet Vent Figure 22 1 CAUTION Never draw outside combustion air from Wall floor or ceiling cavity Enclosed space such as an attic or garage CAUTION THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR WALL AND CEILING ROOF MUST BE MAINTAINED Do NOT cut throu...

Страница 23: ... 3 Surround Std Panel For Cast Trim SP MTVS CST Component Pack 7036 041 Surround Std Panel w Gold Trim No Longer Available SP MTVS GD Component Pack 7036 042 Trim Panel Set Gold SRV250 4660 Surround Std Panel w Nickel Black Trim SP MTVS NB Component Pack 7036 042 Trim Set Black Nickel 7019 027 Trim Cast Matte Black 811 0930 Sienna Bronze TR CAST CSB No longer available TR CAST CWL Mahogany 811 096...

Страница 24: ...e purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Dealership purchased from ________________________________________ Dealer phone _1 _____ _____ ______ Notes ________________________________________________________________________________________ ______...