8
7061-196J
April 24, 2019
Explorer II
Model:
Explorer II Wood Appliance
Laboratory:
Intertek
Report No & Date:
10126132PRT
Type:
Safety
Standard:
UL 1482-07; ULC S627-00
EPA Certification #:
925
EPA Certified Emissions:
2.2 grams per hour
*LHV Tested Efficiency:
78.3%
**HHV Tested Efficiency:
72.4%
***EPA BTU Output:
11,200 to 35,900 / hr.
****Peak BTU/Hour
Output:
61,000
Vent Size:
6 inches
Firebox Size:
2.42 cubic feet
Recommended Log
Length:
20 inches
Fuel:
Seasoned Cord Wood
(20% moisture)
* Weighted average LHV (Low Heating Value) efficiency
using Douglas Fir dimensional lumber and data collected
during EPA emission tests. LHV assume the moisture is
already in a vapor state so there is no loss is energy to
vaporize.
**Weighted average HHV (High Heating Value) efficiency
using Douglas Fir dimensional lumber and data collected
during EPA emission tests. HHV includes the energy
required to vaporize the water in the fuel.
***A range of BTU outputs calculated using HHV
Efficiency and the burn rates from the EPA tests, using
Douglas Fir dimensional lumber.
****A peak BTU out of the appliance calculated using
the maximum first hour burn rate from the High EPA Test
and BTU content seasoned cordwood (8600) times the
efficiency.
1
Listing and Code Approvals
A. Appliance Certification
B. BTU & Efficiency Specifications
The Quadra-Fire Explorer II Wood Appliance (ACC) meets the U.S. Environmental Protection Agency’s crib wood
emission limits for wood appliances sold after May 15, 2015.
This wood appliance needs periodic inspection and repair for proper operation. It is against federal regulations to operate
this wood appliance in a manner inconsistent with operating instructions in this manual.
NOTE:
This installation must conform with local codes. In the absence of local codes you must comply with the UL1482-11,
UL 737-11, (UM) 84-HUD and NPFA211 in the U.S.A. and the ULC S627-00 and CAN/CSA-B365 Installation
Codes in Canada.
NOT APPROVED FOR MOBILE HOME INSTALLATIONS IN CANADA!