background image

March 26, 2020

7039-804B

9

Operating Instructions

User Guide

1.  Symptoms of Over-Firing 

Symptoms of over-firing may include one or more of 

the following:

 - Chimney connector or appliance glowing

 - Roaring, rumbling noises

 - Loud cracking or banging sounds

 - Metal warping

 -

Chimney fire

2.  What To Do if Your Appliance is Over-Firing

 - Immediately close the door and air controls to 

reduce air supply to the fire.

 -

If you suspect a chimney fire, call the fire 

department and evacuate your house.

 - Contact your local chimney professional and have 

your appliance and appliance pipe inspected for 

any damage.

 - Do not use your appliance until the chimney 

professional informs you it is safe to do so.

A. Over-Firing Your Appliance

B. Wood Selection & Storage

Burn only dry seasoned wood. Store wood under cover, 

out of the rain and snow. Dry and well-seasoned wood will 

not only minimize the chance of creosote formation, but will 

give you the most efficient fire. Even dry wood contains at 

least 15% moisture by weight, and should be burned hot 

enough to keep the chimney hot for as long as it takes to 

dry the wood out - about one hour. It is a waste of energy to 

burn unseasoned wood of any kind.

Visit 

www.quadrafire.com/shopping-tools/videos

 to view 

product and use & care videos.

Dead wood lying on the forest floor should be considered 

wet, and requires full seasoning time. Standing dead wood 

can be considered to be about 2/3 seasoned. To tell if wood 

is dry enough to burn, check the ends of the logs. If there 

are cracks radiating in all directions from the center, it is 

dry. If your wood sizzles in the fire, even though the surface 

is dry, it may not be fully cured.

Splitting wood before it is stored reduces drying time.  

Wood should be stacked so that both ends of each piece 

are exposed to air, since more drying occurs through the 

cut ends than the sides. This is true even with wood that 

has been split. Store wood under cover, such as in a shed, 

or covered with a tarp, plastic, tar paper, sheets of scrap 

plywood, etc., as uncovered wood can absorb water from 

rain or snow, delaying the seasoning process.

C. Burning Process

In recent years there has been an increasing concern 

about air quality. Much of the blame for poor air quality 

has been placed on the burning of wood for home heating. 

In order to improve the situation, we at Quadra-Fire 

have developed cleaner-burning wood appliances that 

surpass the requirements for emissions established by our 

governing agencies. These wood appliances, like any other 

appliances, must be properly operated in order to insure 

that they perform the way they are designed to perform. 

Improper operation can turn most any wood appliance into 

a smoldering environmental hazard.

1.  Kindling or First Stage

It helps to know a little about the actual process of 

burning in order to understand what goes on inside 

a appliance. The first stage of burning is called the 

kindling stage. In this stage, the wood is heated to a 

temperature high enough to evaporate the moisture 

which is present in all wood. The wood will reach the 

boiling point of water (212°F) and will not get any hotter 

until the water is evaporated. This process takes heat 

from the coals and tends to cool the appliance.

Fire requires three things to burn - fuel, air and heat. 

So, if heat is robbed from the appliance during the 

drying stage, the new load of wood has reduced the 

chances for a good clean burn. For this reason, it is 

always best to burn dry, seasoned firewood. When 

the wood isn’t dry, you must open the air controls and 

burn at a high burn setting for a longer time to start it 

burning. The heat generated from the fire should be 

warming your home and establishing the flue draft, not 

evaporating the moisture out of wet, unseasoned wood, 

resulting in wasted heat.

Fire Risk. Do not over-fire.

Over-firing may ignite creosote or will damage 

the appliance and chimney.

To prevent over-firing your appliance, 

DO NOT:

• 

Use flammable liquids

•  Overload with wood

•  Burn trash or large amounts of 

scrap lumber

• 

Permit too much air to the fire

WARNING

Hearth & Home Technologies WILL NOT warranty 

appliances that exhibit evidence of over-firing. Evidence 

of over-firing includes, but is not limited to:

•  Warped air tube

•  Deteriorated refractory brick retainers

• 

Deteriorated baffle and other interior components

Содержание DISCOVERY I Series

Страница 1: ...AND cool down WARNING Hot glass and appliance will cause burns Do not touch glass until it is cooled Use leather gloves when reloading fuel NEVER allow children to touch glass Keep children away CARE...

Страница 2: ...e chaque c t C D ALCOVE TOP VIEW VUE DU HAUT DE L ALC VE G A B ALCOVE SIDE VIEW VUE DE C T DE L ALC VE DO NOT REMOVE THIS LABEL NE PAS ENLEVER L TIQUETTE 16 from glass 8 in USA Fuel loading door 5 3 4...

Страница 3: ...Efficiency Specifications 7 D Glass Specifications 8 E Mobile Home Approved 8 F Sleeping Room 8 G California Prop65 8 2 Operating Instructions 9 A Over Firing Your Appliance 9 B Wood Selection Storag...

Страница 4: ...pilots blowers junction boxes wire harnesses transformers and lights excluding light bulbs X X Molded Refractory Panels Glass Liners X Vent Free Burners Vent Free Logs X X Castings Medallions and Baf...

Страница 5: ...ot covered by this warranty Limited Catalyst Warranty o For wood burning products containing a catalyst the catalyst will be warranted for a six year period to the original purchaser at catalyst WARRA...

Страница 6: ...DD KINDLING LIGHT THE PAPER ADD MORE WOOD REDUCE AIR CONTROLS Set to desired heat output LOW BURN RATE CONTROL Upper Right Corner AUTOMATIC COMBUSTION CONTROL ACC Middle right hand side LOW The applia...

Страница 7: ...grams per hour LHV Tested Efficiency 82 3 HHV Tested Efficiency 76 1 EPA BTU Output 13 700 to 29 500 hr Peak BTU Hour Output 44 400 Vent Size 6 inches Firebox Size 1 48 cubic feet Recommended Log Leng...

Страница 8: ...t be maintained The appliance must be properly grounded to the frame of the mobile home with 8 copper ground wire and chimney must be listed to UL103 HT or a listed UL 1777 full length six inch 152mm...

Страница 9: ...rain or snow delaying the seasoning process C Burning Process In recent years there has been an increasing concern about air quality Much of the blame for poor air quality has been placed on the burni...

Страница 10: ...t Up Air Controls before reloading This livens up the coal bed and reduces excessive emissions opacity smoke Open door slowly so that ash or smoke does not exit appliance through opening You should al...

Страница 11: ...Using Burn Rate Air Control ACC System Injury Risk Gloves recommended CAUTION 3 Manual Timer Over Ride If you need to shut the ACC system off before it goes through the cycle of shutting itself off 2...

Страница 12: ...b stops At that point move the Burn Rate Air Control spring handle to 1 8 1 2 from the low setting 3 Medium high burn setting Burn Rate Air Control spring handle up to high position Then activate the...

Страница 13: ...e appliance NEVER light or rekindle fire with kerosene gasoline or charcoal lighter fluid the results can be fatal 6 Once the kindling is burning quickly add several full length logs 3 inches 76mm or...

Страница 14: ...ith a speed control Adjust the fan speed by turning the speed control clockwise to Low or counterclockwise to High 3 Snap Disc Location If you find the blower coming on and off at undesirable temperat...

Страница 15: ...e furnace and air conditioning return vents are not located in the immediate vicinity of the appliance Avoid installing the appliance near doors walkways or small isolated spaces Recessed lighting sho...

Страница 16: ...TACT YOUR DEALER for additional information regarding operation and troubleshooting Visit www quadrafire com to find a dealer L Frequently Asked Questions WARNING Fire Risk DO NOT BURN GARBAGE OR FLAM...

Страница 17: ...od to help prevent cap blockage and creosote build up Firebrick Ash Removal WEEKLY or after every 25 loads of wood Ashes must be cool before you can dispose of the ashes in a non combustible container...

Страница 18: ...y connector and chimney should be inspected once every 2 months during the heating season to determine if a creosote or soot buildup has occurred If creosote or soot has accumulated it should be remov...

Страница 19: ...he glass helping to keep smoke from adhering to its surface When operated at a low burn rate less air will be flowing over the glass and the smokey relatively cool condition of a low fire will cause t...

Страница 20: ...tact with the back of the firebox and even with each other in the front Ceramic Blanket Back of Firebox Baffle Board Baffle Retainer Bracket WARNING Fire Risk Firebox damage due to improper baffle pla...

Страница 21: ...ey Height Rise and Run on page 13 of the Installation manual Open window below the appliance towards the wind Wood condition is too wet too large Use dry seasoned wood refer to Wood Selection Storage...

Страница 22: ...n next firing Refer to maintenance instructions Service Part SRV7000 013 1 Ensure that the fire is out and the appliance is cool to the touch 2 Protect a table or counter top with padding or towels Pr...

Страница 23: ...vice Part SRV230 0470 1 Locate the snap disc bracket assembly at the bottom left rear corner of the appliance 2 A magnet holds the bracket to the appliance Pull the bracket down away from the applianc...

Страница 24: ...he ceramic blanket 4 Re install the baffle pieces one piece at a time Be sure the baffle boards are even with the front manifold tube and is resting on all tubes Figure 24 3 and Figure 24 4 5 To re in...

Страница 25: ...liance use a flat tool to pry from bottom if needed Figure 25 4 WARNING Fire Risk Use only noncombustible materials as a decorative tile Figure 25 1 Figure 25 3 2 Figure 25 2 Figure 25 6 1 Figure 25 4...

Страница 26: ...order to replace the tube channel assembly a clearance of 19 inches 483mm is required on the right side of appliance in order to remove the tubes with the appliance in place If space is not available...

Страница 27: ...March 26 2020 7039 804B 27 A Service Maintenance Log 6 Reference Materials Date of Service Performed By Description of Service...

Страница 28: ...March 26 2020 7039 804B 28 Date of Service Performed By Description of Service...

Страница 29: ...29 B Exploded View Service Parts DISCOVERY I C R Beginning Manufacturing Date Jan 2020 Ending Manufacturing Date Active Part number list on following page 02 20 Wood Stove 16 1 2 3 4 6 7 8 5 9 11 10...

Страница 30: ...ffle Board Pkg of 2 SRV7039 111 Y 6 Baffle Protection Channel SRV7039 144 7 Tube Support Rack SRV7039 108 8 Brick Retainer 7033 149 9 Tube Channel Assembly SRV7039 004 Y 10 Brick Assembly Complete Set...

Страница 31: ...320 16 2 Rope Door 3 4 x 84 7 Ft 832 1680 Y 16 3 Door Glass Assembly SRV7000 013 Y Gasket Glass Tape 3 4 x 1 8 5 Ft 832 0460 Y 16 4 Glass Frame Set GL FRM 21M Screw Flat Head Phillips 8 32 x 1 2 Pkg o...

Страница 32: ...ENTS PART NUMBER 20 1 Burn Rate Control Assembly 7039 016 20 2 Spring Handle 1 4 250 8340 Y 20 3 Door Gasket 7033 282 Y 20 4 Timer Air Control Assembly SRV7039 015 Y Rear Air Door Assembly 7037 013 Y...

Страница 33: ...000 194 Y Blower Convection 812 4900 Y Component Pack 7033 051 Snap Disc Bracket Assembly SRV7033 036 Snap Disc 1 Convection Blower SRV230 0470 Y Wire Harness Blower 7033 262 Logo Quadra Fire Pkg of 1...

Страница 34: ...and maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance...

Отзывы: