CB1200-I PELLET STOVE SERVICE MANUAL
CB1200-I PELLET STOVE SERVICE MANUAL
IGNITER TROUBLE-SHOOTING
IGNITER
JUNCTION BOX
IGNITER CIRCUIT
TAN (HT)
TAN (HT)
ACCY
JUMPER
1
3
4
5
6
2
1) TURN ON THE THERMOSTAT CIRCUIT AND MAKE SURE THE CALL LIGHT IS ON.
B. IF POWER IS PRESENT-----REPLACE THE IGNITER
A. IF NO POWER------CHECK THE WIRE HARNESS OR REPLACE THE CONTROL BOX
2) CHECK FOR POWER AT THE IGNITER:
7-31-2002 PAGE 8 250-7700
Содержание CLASSIC BAY 1200