CB1200-I PELLET STOVE SERVICE MANUAL
CB1200-I PELLET STOVE SERVICE MANUAL
E. SLOW OR SMOKEY START UP
1) CLEAN FIREPOT
2) FEED ADJUSTMENT PLATE MAY BE SET TOO HIGH
3) CHECK EXHAUST BLOWER AND HEAT EXCHANGER
4) MAKE SURE TRAP DOOR UNDER FIREPOT IS CLOSED
TROUBLE SHOOTING & REPAIR
G. FEED SYSTEM FAILS TO START
1) CHECK FRONT DOOR AND MAKE SURE IT IS CLOSED
2) CHECK TO SEE IF CALL LIGHT IS ON
3) CHECK THERMOSTAT
4) CHECK FEED MOTOR AND VACUUM SWITCH
5) CHECK EXHAUST SYSTEM FOR OBSTRUCTIONS
H. THERMOSTAT WILL NOT START UNIT
1) CHECK THERMOSTAT WIRES FOR CONTINUITY
2) CHECK THE “ACCESSORY JUMPER WIRE” ON THE J-BOX
3) CHECK #2 SNAP DISC
4) CHECK THE RESET BUTTON
5) CHECK FOR POWER TO THE STOVE
6) CHECK CONTROL BOX
F. STOVE RUNS FOR 10 MINUTES -- THEN STOPS FEEDING FUEL
1) CHECK THERMOCOUPLE
*GREEN LIGHT-------2.5 mVDC ( +.5mV)
*RED LIGHT-----------12.1 mVDC (+ 1mV)
2) ADJUST FEED ADJUSTMENT PLATE FOR LARGER FIRE
3) CHECK THERMOCOUPLE COVER
*COVER NEEDS TO TOUCH THE END OF THE T-COUPLE WIRE
*COVER SHOULD EXTEND 1 3/4” INTO FIREPOT
4) CHECK CONTROL BOX
7-31-2002 PAGE 4 250-7700
Содержание CLASSIC BAY 1200
Страница 30: ...CB1200 I PELLET STOVE SERVICE MANUAL ...