16
February 5, 2019
7022-515I
CASTILE INSERT
SOFTWARE RESET:
Software reset is used to erase ALL temperature events,
and to return all user-adjustable software settings back to
their original factory default settings.
To Perform a Software Rest:
1.
Verify the thermostat’s keypad is not locked.
2.
Move TEMPERATURE switch to OFF.
3.
Press and hold the UP, DOWN, and NEXT buttons all
at the same time for at least 5 seconds. When the LCD
display screen will become fully populated let go of all
buttons at that point the screen will return to normal.
The clock will have to be changed to match the current day
and time.
T. Thermostat Battery Replacement
This thermostat is powered by two “AA” Alkaline batteries.
The batteries should be replaced AT LEAST once per
year to ensure reliable operation or sooner if the LO BATT
appears on the display screen. The batteries are located on
the back of the thermostat’s circuit board. The front portion
of the thermostat can be removed from the back half by
using the tabs on the top edge of the thermostat housing
(
Figure 16.1
).
Figure 16.1
Figure 16.2 - Full
battery icon
Figure 16.3 - Low
battery icon
When installing new batteries, it is recommended using
only brand new “AA” size alkaline batteries. Please verify
the polarity markings shown in the battery compartment
before adding batteries to the compartment. When finished,
line up the front of the thermostat to the base, and firmly
press together to securely latch the front and back halves
together properly.
BATTERY GRAPHIC:
Anytime time the batteries are physically present in the
thermostat, there will be a visual indicator showing the
life of the battery. This will appear on the display screen
(
Figures 16.2 & 16.3
).
Shock hazard.
• Do NOT remove grounding prong from plug.
• Plug directly into properly grounded 3 prong
receptacle.
• Route cord away from appliance.
•
Do NOT route cord under or in front of appliance.
CAUTION
Figure 16.4
CONNECT THERMOSTAT WIRES TO APPLIANCE:
There is a 4 screw terminal block located on the back lower
left corner of the stove directly above the power cord inlet.
The center 2 screws are for the thermostat wires
(Figure