background image

15

February 5, 2019

7022-515I

CASTILE INSERT

S. Thermostat Other Features

TEMPERATURE  CALIBRATION:

The internal temperature sensor in this thermostat is 

accurately calibrated at the factory, and in most cases 

alterations to this setting should not be needed. The 

temperature calibration feature allows you to manually 

offset the measured temperature by as much as plus 

or minus 5°F (3°C) from its original value. If several 

thermostats are used in the same house, this feature can 

be used to synchronize this thermostat to the others.

Change the temperature calibration:

1. 

Move TEMPERATURE switch to OFF.

2.  Move SET switch to RUN.

3. 

Press and hold both UP and DOWN buttons together 

for at least 5 seconds; the words SET and CAL will 

appear on the display along with a single flashing 

temperature digit.

4. 

Use the UP or DOWN buttons to change the number of 

degrees desired for adjustment; 0° is the default value 

and also means no correction will be applied.

5.  Press the NEXT button to accept the setting.

NOTE: 

All other features need to be completed in a 

timely manner as the thermostat will time out 

after 10 seconds.

HW

RST

HARDWARE RESET:

The hardware reset button; labeled HW RST, is a small 

round push button that is located in the middle of the circuit 

board, just below the battery holder 

(Figure 15.1)

. Pressing 

this button will:

• 

Cause the LCD display screen to become fully 

populated

• 

Thermostat to perform an internal system check of its 

components

If the thermostat appears to be acting in an erratic manner, 

pressing the HW RST button may remedy this behavior. 

The temperature programs are not erased when a 

hardware reset is performed, however the clock will have to 

be changed to match the current day and time.

Figure  15.1

COPY PROGRAM FEATURE:

Using similar instructions as 

SET TEMPERATURE 

PROGRAMS

 the COPY button will allow a whole day of set 

program events to be copied to another day.

1.  Move 

TEMPERATURE switch to HEAT as well as 

move SET switch to TEMP PROG position.

2. 

Starting with Monday, use the UP or DOWN buttons 

to adjust the start time and set temperature for the 

MORN, DAY, EVE, and NITE events. Press the COPY 

button and then press the  NEXT button to advance to 

Tuesday.

3. 

With Tuesday displayed press COPY button. As 

all programs events from Monday will be copied to 

Tuesday (this will advance automatically to the next 

day; Wednesday, as the word COPY will appear on the 

screen for one second).

4. 

Continue in this pressing COPY button to set desired 

days with original setting.

NOTE: 

The word COPY will not appear on the display 

for Monday, but will display each day afterwards 

for approximately one second and the day of the 

week will automatically advance forward to the 

next day.

KEYPAD LOCKOUT:

There is the option to lock the front panel buttons to prevent 

unauthorized tampering of your thermostat settings.

To Lock the Keypad:

1. 

Move TEMPERATURE switch to HEAT.

2.  Move SET switch to RUN.

3. 

Perform a single press of each button in the following 

sequence:

• 

NEXT, NEXT, NEXT, HOLD

A padlock will appear on the display screen.

To Unlock the Keypad:

1. 

Move TEMPERATURE switch to HEAT.

2.  Move SET switch to RUN.

3. 

Perform a single press of each button in the following 

sequence:

• 

NEXT, NEXT, NEXT, HOLD

A padlock will no longer be present on the display screen.

Содержание CASTILE Series

Страница 1: ...or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Do not over fire If appliance or chimney connector glows you are over firing Over firing will void your warranty Comply with all minimum clearances to combustibles as specified Failure to comply may cause house fire HOT SURFACES Glass and other surfaces are hot during operatio...

Страница 2: ...instructions du fabricant et des codes locaux pour les précautions requises pour passer une cheminée à travers un mur ou un plafond combustibles et les compensations maximums Inspectez et nettoyez la cheminée fréquemment Ne pas connecter cet appareil à une cheminée servant un autre appareil Utilitsez le système de ventilation de 3 or 4 inch 76 102mm de diametre de type L ou PL Testé à ASTM 1509 04...

Страница 3: ... Combustible Materials 9 D Fuel Material and Fuel Storage 9 E Before Your First Fire 10 F Filling the Hopper 10 G General Operating Information 10 H Starting Your First Fire 11 I Fire Characteristics 11 J Feed Rate Adjustment Instructions 11 K Ignition Cycles 12 L Insert Removal 12 M Restarting the Appliance 12 N Clear Space 12 O Thermostat Controls 13 P Thermostat Setup Options 13 Q Thermostat Op...

Страница 4: ...ctronic components and glass X X X Factory installed blowers X Molded refractory panels X Ignition Modules X Firepots burnpots mechanical feeders auger assemblies X Vent Free burners Vent Free ceramic fiber logs Aluminized Burners X X Castings and Baffles 6 years 3 years X Catalyst limitations listed 7 years 3 years X X Manifold tubes HHT chimney and termination 10 years 1 year X Burners logs and ...

Страница 5: ...anging a warranty call Travel and shipping charges for parts are not covered by this warranty Limited Catalyst Warranty o For wood burning products containing a catalyst the catalyst will be warranted for a six year period as follows if the original o From 37 to 72 months a pro rated credit will be allowed against a replacement catalyst and labor credit necessary to install Amount of Time Since Pu...

Страница 6: ...to water or weather damage which is the result of but not limited LIMITATIONS OF LIABILITY have other rights which vary from state to state EXCEPT TO THE EXTENT PROVIDED BY LAW HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE ...

Страница 7: ...llet appliances sold after May 15 2015 This pellet insert needs periodic inspection and repair for proper operation It is against federal regulations to operate this pellet insert in a manner inconsistent with operating instructions in this manual EPA Certification 940 14 EPA Certified Emissions 1 8 grams per hour LHV Tested Efficiency N A HHV Tested Efficiency N A EPA BTU Output 8 500 to 28 200 h...

Страница 8: ...ance Modification of the appliance Installation other than as instructed by Hearth Home Technologies Installation and or use of any component part not approved by Hearth Home Technologies Operating appliance without fully assembling all components Operating appliance without legs attached if supplied with appliance Do NOT Over fire If appliance or chimney connector glows you are over firing Any su...

Страница 9: ...Always burn dry fuel Burning fuel with high moisture content takes heat from the fuel and tends to cool the appliance robbing heat from your home Damp pellet fuel can clog the feed system WARNING Fire Risk Do not operate appliance before reading and understanding operating instructions Failure to operate appliance properly may cause a house fire A Fire Safety To provide reasonable fire safety the ...

Страница 10: ...lame height feed rate may need adjusting occasionally Performance Higher ash content requires the ash drawer to be emptied more frequently Hardwoods require more air to burn properly Premium wood pellets produce the highest heat output Burning pellets longer than 1 1 2 inches 38mm can cause an inconsistent fuel feed rate and or missed ignitions Changing to Different Fuel Type Empty the hopper of t...

Страница 11: ...l switch to the desired setting J Feed Rate Adjustment Instructions The feed adjustment control rod is factory set and should be adequate for most fuels The control rod will slide by only loosening the wing screw However if the flame height is too high or too low you will need to adjust the feed rate Wait until the appliance has been burning for 15 minutes before making your adjustments and allow ...

Страница 12: ...othing furniture or draperies Maintain a minimum clearance of 3 feet 914mm in front of appliance WARNING Fire Risk Keep combustible materials gasoline and other flammable vapors and liquids clear of appliance WARNING Do NOT store flammable materials in the appliance s vicinity DO NOT USE GASOLINE LANTERN FUEL KEROSENE CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS TO START OR FRESHEN UP A FIRE IN THIS ...

Страница 13: ...rt with item 01 and is advanced to each following item by a single press of the NEXT button The options for each item are changed using the UP or DOWN buttons ITEM 01 CLK CLOCK FORMAT 12Hr default This displays the clock times using standard AM and PM values 24Hr This displays the clock times using the military time format example 22 00 hours without using AM or PM ITEM 02 TMP TEMPERATURE SCALE F ...

Страница 14: ...or DOWN The temporarily changed set temperature will return to the programmed value stored in memory when start time of the next upcoming scheduled event is reached MORN DAY EVE OR NITE While the temporary changed set temperature is in effect the word OVERRIDE will be shown on the display screen To cancel move TEMPERATURE switch to OFF and back to HEAT again TEMPERATURE HOLD Temperature hold is us...

Страница 15: ...utton may remedy this behavior The temperature programs are not erased when a hardware reset is performed however the clock will have to be changed to match the current day and time Figure 15 1 COPY PROGRAM FEATURE Using similar instructions as SET TEMPERATURE PROGRAMS the COPY button will allow a whole day of set program events to be copied to another day 1 Move TEMPERATURE switch to HEAT as well...

Страница 16: ...d from the back half by using the tabs on the top edge of the thermostat housing Figure 16 1 Figure 16 1 Figure 16 2 Full battery icon Figure 16 3 Low battery icon When installing new batteries it is recommended using only brand new AA size alkaline batteries Please verify the polarity markings shown in the battery compartment before adding batteries to the compartment When finished line up the fr...

Страница 17: ...e operation or longevity of your insert 2 Ash buildup on glass 2 This is normal Clean the glass 3 Glass has turned dirty 3 Excessive build up of ash The lower burn settings will produce more ash the higher burn settings produce less The more it burns on low the more frequent cleaning of the glass is required 4 Fire has tall flames with black tails and is lazy 4 The feed rate needs to be reduced or...

Страница 18: ...rning Alternate Fuels Every 1 bag OR X Glass When clear view of fire pot becomes obscured OR X Heat Exchanger Drop Tube Every 1 ton of fuel OR X Hopper Every 1 ton of fuel or when changing fuel types OR X Venting System More frequently depending on the fuel type OR X This pellet insert has a manufacturer set minimum low burn rate that must not be altered It is against federal regulations to alter ...

Страница 19: ... in this section for more details on fuels with high ash content 2 Cleaning Fire pot with Cleaning Rod Fire pot Clean Out Tool Frequency Daily or more often as needed By Homeowner a The appliance must be in complete shutdown and cool and the exhaust blower off If you are just cleaning the fire pot there is no need to unplug the insert b Pull fire pot cleaning rod OUT and IN a couple of times to he...

Страница 20: ...haust blower is off b A more thorough cleaning is needed to remove the excess ash that is left behind from the use of the cleaning rods for the heat exchanger tubes c The ash will be resting on the back of the baffle This will require removing the cast baffle Please refer to page 35 for a detailed explanation of removing the baffle 8 Cleaning the Exhaust Path Frequency Every 25 bags or monthly or ...

Страница 21: ...r view of the fire pot is obscure By Homeowner a Appliance must be completely cool before cleaning glass b Use a damp paper towel or any non abrasive glass cleaner Wipe off with dry towel 12 Door Latch Inspection Frequency Prior to heating season By Homeowner The door latch is non adjustable but the gasket between the glass and firebox should be inspected periodically to make sure there is a good ...

Страница 22: ...hown in Figure 22 2 The correct flame size when good quality premium pellet fuel is burned is shown in Figure 22 3 If the ash buildup exceeds the half way point in the fire pot IMMEDIATE ATTENTION AND CLEANING IS REQUIRED C Soot or Creosote Fire Awareness The chimney should be inspected periodically during the heating season to determine if a creosote build up has occurred If a significant layer o...

Страница 23: ...Call light on No fire Partially burned fuel in fire pot Fire pot clean out plate not closed Fire pot is dirty missed ignition Check that fire pot clean out plate is fully closed Clean fire pot Make sure there is no clin ker in the fire pot See page 19 Clinkers may have to be broken up with fire pot clean out tool or other means Call light on No fire Unburned pellets in fire pot Fire pot clean out ...

Страница 24: ...oss of vacuum Empty hopper of fuel Use a wet dry vacuum cleaner to remove remaining fuel from hopper including feed tube Check feed chute for obstructions Loosen 2 screws and jiggle feed assembly Check that set screw is tight on feed spring shaft at end of feed motor Check connections on feed motor replace if defective No call light Appliance does not begin start sequence Thermostat not set to a h...

Страница 25: ... panels Change fuel brand to pre mium Check that fire pot clean out plate is fully closed Reduce feed rate using feed rate adjustment control rod located inside hopper Nuisance shutdowns Low flame Sawdust buildup in hopper Feed motor is reversing Defective thermocouple Defective control box Fire pot more than 1 2 full Increase feed by opening feed rate adjust ment control rod located inside hopper...

Страница 26: ...are purple white and the wires from the blower are black f The blower is held in place with a wing screw g Re install in reverse order A Blower Replacement 1 Combustion Exhaust Blower Replacement a If you have adequate clearance you will not have to remove the panel set and disconnect flue if not then you will have to remove the panel set and disconnect the flue b Pull appliance out onto the heart...

Страница 27: ...igure 27 4 6 The baffle does not completely cover the top of the firebox There is an opening on the left as shown in Figure 27 5 Tabs Figure 27 4 Figure 27 5 B Baffle Brick Replacement 1 Follow proper shutdown procedures in Section 10 2 The top baffle has a hook on the bottom left side that rests on the top lip of the cast brick There is a tab on the bottom right side that hooks into the side brac...

Страница 28: ...28 February 5 2019 7022 515I CASTILE INSERT Figure 28 2 Figure 28 3 Figure 28 4 Lift brick pull forward at an angle and drop down into notches Figure 28 1 Re installing Baffle Brick Set Cont d ...

Страница 29: ... igniter wires are clear of any movement i e ash drawer fire pot cleaning rod cleaning slide plates etc 5 Re install the ash drawer and then re install the side panel and re connect the power E Glass Replacement 1 Open the face and remove door from the appliance by lifting door off of hinge pin and lay on a flat surface face down 2 Using a screwdriver tap the bottom of the rope retainer rod to pus...

Страница 30: ...ight will automatically start blinking 6 blinks every 10 seconds for 60 seconds depending upon setting and then will stop E NOTE Do NOT open the control box This will void the warranty If you need to plug in or remove the control box you must first unplug the appliance 7 Heat Exchangers The heat exchangers transfer heat from the exhaust system into convection air There are 2 clean out rods located...

Страница 31: ...curs the snap disc with automatically reset itself 19 Snap Disc 3 Burn Back Protector 250 F Snap disc 3 is mounted on the back of the auger tube in the center of the appliance and has a reset button To access it remove the right side panel If the fire tries to burn back into the feed system or push exhaust up the feed tube this snap disc will shut the entire system off This disc must be manually r...

Страница 32: ... RIGHT SIDE Control Box Junction Box Reset Button Heat Output Switch Power Cord Outlet Thermostat Block Fuse Red Call Light R ed G reen Am ber Light Blue Light Firepot Cleaning Rod Cleaning Rods 10 Heat Exchanger Tubes Feed Motor Combustion Blower Vacuum Switch Convection Blower Leveling Bolt B Component Locations ...

Страница 33: ...33 February 5 2019 7022 515I CASTILE INSERT C Service and Maintenance Log Date of Service Performed By Description of Service ...

Страница 34: ...34 February 5 2019 7022 515I CASTILE INSERT Date of Service Performed By Description of Service ...

Страница 35: ...ng Manufacturing Date Active Castile Insert B Castile Pellet Insert CASTILEI MBK CASTILEI PMH CASTILEI CSB CASTILEI CWL Feb 2011 Thru June 2011 Part number list on following pages 1 2 3 4 8 9 7 6 5 10 11 12 13 14 15 16 17 18 19 22 23 24 25 36 26 20 21 27 28 29 30 31 32 37 34 35 02 19 D Exploded Drawings ...

Страница 36: ... 6 Side Matte Black 414 0050BK Mahogany SRV414 0050PMH Sienna Bronze SRV414 0050CSB 7 Glass Assembly Side 1 Piece 5 7 8 in W x 9 in H Interchangeable SRV414 5380 Y Gasket Channel 1 8 x 1 1 4 10 Ft 7000 377 10 Y 8 Backer Side Window Interchangeable 414 0280 9 Door Hinge Assembly SRV7022 012 Y Hinge Door Male SRV450 2810 10 De ector Bottom Airwash 413 0680 11 Baf e Assembly 7001 034 Y 12 Door Rope 7...

Страница 37: ...Hinge Female SRV450 2910 23 5 Glass Assembly w gasket 17 1 4 W x 11 5 8 H Pre 00702302482 SRV7001 038 Y Post 00702302482 SRV7021 032 Y Gasket Tadpole 10 Ft 842 5130 Y Tape 1 2 x 1 16 10 Ft 240 0290 10 Y Tape Door Corner SRV7027 227 Y 23 6 Retainer Rope SRV7001 192 Y 24 Vacuum Switch SRV7000 531 Y 25 Corner Post SRV7022 104 26 Bolt GRD 2 Tap 3 8 x 4 223 0140 27 Snap Disc 110 20 1 SRV230 1220 Y 28 F...

Страница 38: ...pter Assembly SRV414 5850 33 Blower Retainer SRV7058 148 34 Snap Disc 2 SRV7000 268 Y 35 Snap Disc Manual Reset 3 SRV230 1290 Y 36 Convection Blower 150 CFM 812 4900 Y 37 Feed Adjustment Plate SRV7022 119 38 1 Firepot Pull Rod Assembly 414 5270 Y Spring Firepot 200 2050 Washer 1 4 Sae Pkg of 24 28758 24 Y 38 2 Thermocouple Cover Pkg of 10 812 4920 Y 38 3 Thermocouple Clamp SRV7001 203 Y 38 4 Therm...

Страница 39: ...wer Cord 812 1180 Y Harness Thermostat Wire SRV230 0810 Fuse 7 Amp Junction Box Pkg of 10 812 0380 10 Y Hose Vacuum 5 32 Id 3 Ft SRV240 0450 Y Hopper Lid Magnetic Switch SRV7000 375 Y Reset Button Assembly SRV7000 040 Wire Harness Hopper Switch SRV414 1220 Y OPTIONAL ACCESSORIES Adjustable Hearth Support 12 x 50 2 10 H ADJSPT 12 Damper 3 Inch Tall Vertical Installs Only PEL DAMP3 Y Damper 4 Inch T...

Страница 40: ...Programmable PROG STAT Trim Cast Matte Black 811 0930 Footer Left 414 7090MBK Footer Right 414 7100MBK Header 414 7110MBK Trim Leg Left 414 7120MBK Trim Leg Right 414 7130MBK Trim Cast Mahogany 811 0960 Footer Left 414 7090PMH Footer Right 414 7100PMH Header 414 7110PMH Trim Leg Left 414 7120PMH Trim Leg Right 414 7130PMH Trim Cast Sienna Bronze TR CAST CSB Footer Left 414 7090CSB Footer Right 414...

Страница 41: ...eveling Bolt Pkg of 25 220 0080 25 Y Nut Capped Push 1 4 Pkg of 24 7000 157 24 Y Nut Ser Flange Small 1 4 20 Pkg of 24 226 0130 24 Y Nut Wing 8 32 Pkg of 24 226 0160 24 Y Screw Flat Head 1 4 20 Pkg of 24 7000 130 24 Y Screw 1 4 20X3 8 Phillips Button Head Pkg of 24 7000 401 24 Y Screw Flat Head Philips 8 32X1 2 Pkg of 12 220 0490 12 Y Screw Machine Screw 1 4 20X5 8 Pkg of 24 220 0440 24 Y Screw Pa...

Страница 42: ...te purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Dealership purchased from ________________________________________ Dealer phone _1 _____ _____ ______ Notes ________________________________________________________________________________________ _____...

Отзывы: