background image

 1 

 

 

 

 

                        7021-154J 

 

 

 

 

   May 12, 2017

CASTILE-B PELLET APPLIANCE

Model(s):

CASTILE-MBK-B         CASTILE-CWL-B

CASTILE-CSB-B          CASTILE-PMH-B

Installation and service of this appliance should be performed by 

qualified personnel. Hearth & Home Technologies recommends 

HHT Factory Trained or NFI certified professionals.

Installation Manual

Installation & Appliance Set-Up

INSTALLER: Leave this manual with party responsible for use and operation. 

OWNER: Retain this manual for future reference. 

NOTICE: DO NOT DISCARD THIS MANUAL

O-T  L

Tested and 

Listed by

Portland

Oregon USA

OMNI-Test Laboratories, Inc.

C

US

 WARNING

If the information in these instruc-

tions is not followed exactly, a 

fire could result causing property 

damage, personal injury, or death.

 

•  Do not store or use gasoline or other flam

-

mable vapors and liquids in the vicinity of 

this or any other appliance.

•  Do not over fire - If appliance or chimney 

connector glows, you are over firing. Over 

firing will void your warranty.

•  Comply with all minimum clearances to 

combustibles as specified.  Failure to 

comply may cause house fire.

 

HOT SURFACES! 

 

Glass and other surfaces are hot  

 

during operation AND cool down. 

 

Hot glass will cause burns.

• 

Do not touch glass until it is cooled

• 

NEVER allow children to touch glass

• 

Keep children away

• 

CAREFULLY  SUPERVISE  children  in  same  room  as 

fireplace.

• 

Alert children and adults to hazards of high temperatures

• 

High  temperatures  may  ignite  clothing  or  other 

flammable materials.

• 

Keep  clothing,  furniture,  draperies  and  other  flammable 

materials away.

WARNING

CAUTION

Tested and approved for wood pellets or shelled corn only. 

Burning of any other type of fuel voids your warranty.

NOTE

To obtain a French translation of this manual, please contact 

your dealer or visit www.quadrafire.com

Pour obtenir une traduction française de ce manuel, s’il vous 

plaît contacter votre revendeur ou visitez www.quadrafire.com

CAUTION

Check building codes prior to installation.

•  Installation MUST comply with local, regional, state and na

-

tional codes and regulations.

•  Consult local building, fire officials or authorities having juris

-

diction about restrictions, installation inspection, and permits.

Содержание CASTILE-MBK-B

Страница 1: ...minimum clearances to combustibles as specified Failure to comply may cause house fire HOT SURFACES Glass and other surfaces are hot during operation AND cool down Hot glass will cause burns Do not to...

Страница 2: ...Components 5 E Install Checklist 6 3 Dimensions and Clearances 7 A Appliance Dimensions 7 B Clearances to Combustibles UL and ULC 8 C Hearth Pad Requirements UL and ULC 8 D Alcove 9 4 Vent Informatio...

Страница 3: ...ped with 5mm ceramic glass Replace glass only with 5mm ceramic glass Please con tact your dealer for replacement glass D Electrical Rating 115 VAC 60 Hz Start 4 1 Amps Run 1 1 Amps E Mobile Home Appro...

Страница 4: ...the installation Location of the appliance and chimney will affect performance Consideration must be given to Safety convenience traffic flow Placement of the chimney and chimney connector and to mini...

Страница 5: ...ermostat Wall Control Location The thermostat wall control s location will have some affect on the appliance s operation Maximum wire length from appliance is 100 feet 30 48m with continuous non splic...

Страница 6: ...the party responsible for use and operation ATTENTION INSTALLER Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjunction with not instead of the...

Страница 7: ...7 3 Side View Figure 7 4 Side View with Top Vent Adapter 24 in 609mm 24 5 8 in 626mm 12 in 305mm 24 in 609mm 28 9 16 in 725mm 15 15 16 in 405mm 22 7 8 in 582mm 17 in 431mm 16 5 16 in 414mm 28 3 4 in...

Страница 8: ...ecommended extending beneath the flue pipe when installed with horizontal venting or under the Top Vent Adapter with vertical installation CANADA INSTALLATIONS A non combustible floor pro tection exte...

Страница 9: ...Illustrations diagrams are not drawn to scale Actual installation may vary due to individual design preference D Alcove Figure 9 1 All minimums listed are to a combustible surface Minimum Maximum Inc...

Страница 10: ...protruding parts of the structure P 12 in Clearance above roof line for vertical terminations All minimum clearances are listed with an Outside Air Kit OAK installed unless otherwise noted in table be...

Страница 11: ...t with your local HVAC professional to determine the ventilation demands for your house Vent Configurations To reduce probability of reverse drafting during shut down conditions Hearth Home Technologi...

Страница 12: ...zontally from c Not less than 12 inches 305mm above 3 Distance from permanently closed windows a Not less than 12 inches 305mm below horizontally from or above 4 Distance between bottom of termination...

Страница 13: ...2 If the equivalent length of pipe is 12 feet 3 7m with altitude of 6 000 feet 1829m you may use 3 or 4 inch 76 to 102mm diameter type L or PL vent H Pipe Selection Chart The chart will help you in de...

Страница 14: ...cumulate ash and will need to be cleaned more often Try to keep them as short as possible ONE 90 ELBOW Total Horizontal Minimum Vertical Vent Diameter 4 0 3 5 5 3 6 6 3 7 7 3 8 8 4 9 9 4 10 10 4 11 11...

Страница 15: ...stalla tions Must use 3 or 4 inch 76 102mm L or PL Listed pellet venting or Listed double wall pipe and a Quadra Fire Outside Air Kit in mobile homes NOTE In Canada where passage through a wall or par...

Страница 16: ...an out Cover 24 in 610mm Minimum Ceiling Support 6 in 152mm Flue Connector 6 in 152mm Class A Chimney Connector Adapter 3 in to 6 in 76 152mm Top Vent Kit We recommend a minimum of 60 inches 1524mm ve...

Страница 17: ...ce Concrete Cap 1 in 25mm clearance with firestop 6 in 152mm minimum Non combustible Hearth Pad Airtight clean out door Sheathing 2 in 51mm minimum Flashing 1 in 25mm clearance 1 in 25mm clearance wit...

Страница 18: ...N Never draw outside combustion air from Wall floor or ceiling cavity Enclosed space such as an attic or garage Flex Hose Hose Clamp Collar Assembly Trim Ring Termination Cap Assembly Hose Clamp Air I...

Страница 19: ...hort horizontal pipe in the top vent adapter as a guide Install the 4 screws Figure 19 2 6 Install the vent pipe into the top vent adapter be sure to silicone all joints C Rear Vent Rear Vent to Top V...

Страница 20: ...from appliance Do NOT route cord under or in front of appliance CAUTION The appliance comes standard with a wall thermostat and 25 of wire If you need to run more than 25 make sure you use a continuo...

Страница 21: ...S FOR THERMOSTAT WIRES POWER OUTLET FUSE Fuse W R Figure 21 2 Press and pull to remove Press and pull to remove Figure 21 3 Thermostat Operation Digital display Digital display Back light Heat On or O...

Страница 22: ...3280 Part 24 NEVER INSTALL IN A SLEEPING ROOM WARNING Spark Arestor Cap Roof Flashing Storm Collar Joist Shield Firestop Double Wall Connector Pipe Figure 22 1 CAUTION Never draw outside combustion ai...

Страница 23: ...ssembly 7001 044 Outside Air Collar Assembly SRV7001 045 Trim Plate Outside Air Kit 412 7100 Pullrod Handle PULLROD HNDL Smart Batt Il 841 0970 Smart Stat Il 841 0960 Thermostat Mechanical 812 3760 Y...

Страница 24: ...purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Deale...

Отзывы: