5700 Step Top AU Wood Appliance
686mm
686mm
860mm
860mm
279mm
279mm
435mm
435mm
661mm
661mm
699mm
699mm
893mm
893mm
768mm
768mm
828mm
828mm
Figure 8.1 - Front View
Figure 8.2 - Side View
Quadra-fire 5700 Step Top ACC do not require a insulating
Floor Protector, as they are tested and comply with
the minimum Floor Protector requirements of
AS/NZS
2918:2001
.
B. Hearth Protection Requirements
C. Firebox Installation
Appliance Dimensions Continued
WARNING
Fire Risk.
Hearth pads must be installed exactly as specified.
High temperatures or hot embers may ignite
concealed combustibles.
Fire Risk.
• Comply with all minimum clearances to
combustibles as specified.
•
Failure to comply may cause house fire.
WARNING
NOTE
•
The minimum Floor Protector sizes are specified in
the clearance chart, see Figures 9.1 and 9.2 on page
9.
• A Floor Protector can include ceramic tiles with
grouted joints fixed directly onto a wooden floor or a
sheet of toughened glass, panel steel or any other
non combustible material laid directly onto a wooden
floor.
•
If installed directly onto a concrete slab, the concrete
slab can be considered as the floor protector,but
must maintain the minimum measurement listed.
1.
If a separate floor protector is being used position
now. Place the firebox on the floor protector to suit the
minimum installation clearances
(Figures 9.1 and 9.2
on page 9)
.
2.
Systemically restrain the firebox and the floor protector
to the floor.
3.
Fit 2mm x 6mm fixings suitable for the floor material.
DO NOT over tighten.
4.
Fit timber trim pedestal edging to front and back of
base (optional).