Quadra-Fire 57ST-ACC-AU Скачать руководство пользователя страница 7

July 19, 2012

7038-201

Page  7

R

5700 Step Top ACC Wood Burner

C L

 

D

ra

w

in

no

t t

sca

le

 

12

 

Tested flue systems, as per AS/NZS 2918:2001

 

 

 

 

 

 

 

Fig. 5

ADD Cowl

 

 

 

Casing Cover

 

 

Spider Bracket

 

oversized casing cover 

is necessary

 

 

minimum 25mm gap 

between flue pipe casing & 

combustible material

 

 

Non combustible material 

Hebel block or 12mm 

Promina board or similar 

under the flashing

 

 

 

 

25 

25

 

 

Approved Flashing

 

 

Roof Line

 

 

Inner Casing 200mm 

above roof line

 

 

 

Outer Casing

 

 

Inner Casing

 

 

25 

Internal Swage

 

 

 

 

 

25 

25

 

 

 

 

 

12.5

 

 

Vented

 

Ceiling Plate

 

 

 

 

 

 

Pioneer 

Double Flue 

Shield

 

 

Flue Pipe

 

 

 

 

 

 

 

 

 

 

 

CL  

C L

 

 

 

 

 

 

Quadra-fire Millennium

 

 

 

 

 

 

 

Floor

 

Protector

 

The flue crimp must be cut so the swage 

(half-moon bulge after the crimp) fits 

tightly into the spigot.

FLUE PENETRATION

Содержание 57ST-ACC-AU

Страница 1: ...stallations with tested flue systems as per AS NZS 2918 2001 Appendix F with a ceiling angle between 0 30 inclusive For installations with a ceiling angle greater than 30 refer to Fig 6 7 and AS NZS 2...

Страница 2: ...yment in the warmth and comfort of your hearth appliance Thank you for choosing Quadra Fire 5700 STEP TOP ACC JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 2012 2013 2014 INSTALLATION DATE MILLENNIU...

Страница 3: ...700 STEP TOP ACC Wood Burner Dimensions Pedestal Model Quadra Fire 5700 STEP TOP ACC Wood Burner Dimensions Leg Model 33 mm 245 mm 662 mm 945 mm 89 mm 94 mm 699 mm 94 mm 686 mm 535 mm 280 mm 435 mm 37...

Страница 4: ...are tested and comply with the minimum Floor Protector requirements of AS NZS 2918 2001 Note The minimum Floor Protector sizes are specified in the clearance chart see Table 1 2 A Floor Protector can...

Страница 5: ...projection from wall 841 E Min overall floor protector depth 1615 F Min floor protector front width 850 CORNER POSITIONING 45 Drawing not to scale Table 2 Fig 4 FIREBOX INSTALLATION 1 If a separate f...

Страница 6: ...ceptable Solution from 01 07 05 5 Install the outer casing so that i lower end is flush with the underside of the ceiling material and ii with the addition of metal L brackets affix to the outer casin...

Страница 7: ...ombustible material Non combustible material Hebel block or 12mm Promina board or similar under the flashing 25 25 Approved Flashing Roof Line Inner Casing 200mm above roof line Outer Casing Inner Cas...

Страница 8: ...g 4 6 downward distance of casing and 3 x flue distance of the ceiling plate ADD Cowl Casing Cover Spider Bracket Approved Flashing A Ceiling Plate Batten A 3 x flue pipe Ceiling flue pipe Fig 7 ADD C...

Страница 9: ...g the entral tongue to locate inside the flue outlet only Two tabs are provided and if folded back at 90 degrees the bracket and Flue Mounted Shield will mount lower onto the appliance The Flue Mounte...

Страница 10: ...TION IS CONSIDERED THE MAN UFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE CAUTIONS CRACKED AND BROKEN COMPONENTS e g GLASS PANELS OR CERAMIC TILES MAY RENDER THE INSTALLATION UNSAFE WARNING ANY M...

Страница 11: ...July 19 2012 7038 201 Page 11 R 5700 Step Top ACC Wood Burner Service And Maintenance Log Date of Service Performed By Description of Service...

Страница 12: ...TOVE DO NOT DISCARD THIS MANUAL CAUTION Important operating and maintenance instruc tions included Leave this manual with party responsible for use and operation Read understand and follow these instr...

Отзывы: