Quadra-Fire 57ST-ACC-AU Скачать руководство пользователя страница 10

Page  10

7038-201

July 19, 2012

R

5700 Step Top ACC Wood Burner

WARNINGS:

WARNING: THE APPLIANCE AND FLUE SYSTEM SHALL BE INSTALLED IN ACCORDANCE 

WITH AS/NZS 2918 AND THE APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING 

CODE OR CODES.

WARNING: APPLIANCES INSTALLED IN ACCORDANCE WITH THIS STANDARD SHALL 

COMPLY WITH THE REQUIREMENTS  OF AS/NZS 4013 WHERE REQUIRED BY THE REGULA-

TORY AUTHORITY, I.E. THE APPLIANCE SHALL BE IDENTIFIABLE BY A COMPLIANCE PLATE 

WITH THE MARKING ‘TESTED TO AS/NZS 4013’.

ANY MODIFICATION  OF THE APPLIANCE  THAT HAS NOT BEEN APPROVED  IN WRITING BY 

THE TESTING AUTHORITY IS CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED 

FOR COMPLIANCE WITH AS/NZS 4013.

CAUTION: MIXING OF APPLIANCE  OR FLUE SYSTEM COMPONENTS  FROM DIFFERENT 

SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY 

RESULT IN HAZARDOUS CONDITIONS. WHERE SUCH ACTION IS CONSIDERED,      THE MAN

-

UFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE.

CAUTIONS: CRACKED AND BROKEN COMPONENTS,  e.g. GLASS PANELS OR CERAMIC TILES, 

MAY RENDER THE INSTALLATION UNSAFE.

WARNING: ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN 

WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS/NZS 4013.

WARNING:  DO  NOT  USE  FLAMMABLE  LIQUIDS  OR  AEROSOLS  TO  START  OR  REKIN-

DLE  THE FIRE.

WARNING: DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS 

APPLIANCE WHEN ITS OPERATING.

WARNING: DO NOT STORE FUEL WITHIN HEATER INSTALLATION CLEARANCES.

WARNING: FOR OPTIMUM PERFORMANCE FUEL MUST BE LOADED SO THE LOGS LAY 

“FRONT TO REAR” IN PREFERENCE  TO LAYING ACROSS THE WIDTH OF THE FIREBOX. 

SPACES SHOULD BE LEFT BETWEEN THE LOGS TO ENABLE OXYGEN TO GET TO AS MUCH 

OF THE SURFACE OF THE FUEL AS POSSIBLE.

CAUTION: THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN 

ACCORDANCE WITH THESE INSTRUCTIONS.

CAUTION: THE USE OF SOME TYPES OF PRESERVATIVE-TREATED WOOD AS A FUEL CAN BE 

HAZARDOUS.

AS/NZS 2918:2001 General Notes

Содержание 57ST-ACC-AU

Страница 1: ...stallations with tested flue systems as per AS NZS 2918 2001 Appendix F with a ceiling angle between 0 30 inclusive For installations with a ceiling angle greater than 30 refer to Fig 6 7 and AS NZS 2...

Страница 2: ...yment in the warmth and comfort of your hearth appliance Thank you for choosing Quadra Fire 5700 STEP TOP ACC JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 2012 2013 2014 INSTALLATION DATE MILLENNIU...

Страница 3: ...700 STEP TOP ACC Wood Burner Dimensions Pedestal Model Quadra Fire 5700 STEP TOP ACC Wood Burner Dimensions Leg Model 33 mm 245 mm 662 mm 945 mm 89 mm 94 mm 699 mm 94 mm 686 mm 535 mm 280 mm 435 mm 37...

Страница 4: ...are tested and comply with the minimum Floor Protector requirements of AS NZS 2918 2001 Note The minimum Floor Protector sizes are specified in the clearance chart see Table 1 2 A Floor Protector can...

Страница 5: ...projection from wall 841 E Min overall floor protector depth 1615 F Min floor protector front width 850 CORNER POSITIONING 45 Drawing not to scale Table 2 Fig 4 FIREBOX INSTALLATION 1 If a separate f...

Страница 6: ...ceptable Solution from 01 07 05 5 Install the outer casing so that i lower end is flush with the underside of the ceiling material and ii with the addition of metal L brackets affix to the outer casin...

Страница 7: ...ombustible material Non combustible material Hebel block or 12mm Promina board or similar under the flashing 25 25 Approved Flashing Roof Line Inner Casing 200mm above roof line Outer Casing Inner Cas...

Страница 8: ...g 4 6 downward distance of casing and 3 x flue distance of the ceiling plate ADD Cowl Casing Cover Spider Bracket Approved Flashing A Ceiling Plate Batten A 3 x flue pipe Ceiling flue pipe Fig 7 ADD C...

Страница 9: ...g the entral tongue to locate inside the flue outlet only Two tabs are provided and if folded back at 90 degrees the bracket and Flue Mounted Shield will mount lower onto the appliance The Flue Mounte...

Страница 10: ...TION IS CONSIDERED THE MAN UFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE CAUTIONS CRACKED AND BROKEN COMPONENTS e g GLASS PANELS OR CERAMIC TILES MAY RENDER THE INSTALLATION UNSAFE WARNING ANY M...

Страница 11: ...July 19 2012 7038 201 Page 11 R 5700 Step Top ACC Wood Burner Service And Maintenance Log Date of Service Performed By Description of Service...

Страница 12: ...TOVE DO NOT DISCARD THIS MANUAL CAUTION Important operating and maintenance instruc tions included Leave this manual with party responsible for use and operation Read understand and follow these instr...

Отзывы: