September 15, 2011
7045-178
Page 23
41I ACC Wood Insert
R
C. Blower Replacement
1. Remove the 2 screws from the Blower Housing Assem
-
bly using a 5/32 allen wrench.
Figure 23.1.
2. Disconnect the wires from the blower.
3. Remove the 2 screws from the hold down bracket and
pull the blower and bracket forward.
4. Remove the blower from the hold down bracket.
5. Re-install in reverse order. Be certain that the hold down
bracket’s screws are completely seated in the grom
-
ments. Insert the locating tab in the hold down bracket
into the placement slot.
Shock Risk
.
• Do NOT remove grounding prong from plug.
• Plug directly into properly grounded 3 prong
receptacle.
• Route cord away from appliance.
• Do NOT route cord under or in front of appliance.
CAUTION
Do NOT allow hot coals or embers to overflow ash lip
•
May melt protective wire coating on fan power
cord causing electrical short, fire or injury
Fire Risk.
WARNING
Remove Screws from Hold Down
Bracket and Pull Forward
Remove Screws & Pull
Blower Housing Assembly
away from Insert
Blower Housing Assembly
Hold Down
Bracket