Quadra-Fire 3100 Series Скачать руководство пользователя страница 23

MAINTENANCE

CREOSOTE

1. Formation and need for removal:  When wood is burned slowly, it produces tar and other organic vapors which

combine with expelled moisture to form creosote.  The creosote vapors condense in the relatively cool chimney flue of
a newly-started or a slow-burning fire.  As a result, creosote residue accumulates on the flue lining.  When ignited, this
creosote creates an extremely hot fire which may damage the chimney or even destroy the house.  The chimney
connector and chimney should be inspected at least twice monthly during the heating season to determine if a creosote
buildup has occurred.  If creosote has accumulated, it should be removed to reduce the risk of a chimney fire.

2. Inspection:  Inspect the system at the stove connection and at the chimney top.  Cooler surfaces tend to build creosote

deposits quicker, so it is important to check the chimney from the top as well as from the bottom.

3. Removal:  The creosote should be removed with a brush specifically designed for the type of chimney in use.  A

chimney sweep can perform this service.  It is also recommended that before each heating season the entire system be
professionally inspected, and cleaned and repaired if necessary.

CARE AND CLEANING OF GLASS

NOTE:  Remove all labels from glass before lighting the first fire in your stove.
Quadra-Fire stoves are equipped with ceramic super heat-resistant glass, which can only be broken by impact or misuse.
Do not slam stove door or impact the glass.  When closing door, make sure that logs do not protrude against the glass.
Clean glass with a nonabrasive glass cleaner, such as Windex.  Abrasive cleaners may scratch and cause glass to crack.
Inspect glass regularly.  If you find a crack or break, immediately put the fire out and return the door to your dealer for
replacement of glass before further use. Leaving the primary air control open during the entire burn will cause overfiring.
Overfiring the appliance may cause crazing, a white non-removable film on inside of glass. Overfiring voids warranty.
NOTE
: Replace with ceramic glass only.

CARE AND CLEANING OF PLATED SURFACES

Clean 24 karat gold-plated surfaces with vinegar or a glass cleaner before lighting your first fire.

WARNING: When the appliance is equipped with a 24 karat gold-plated door, you must clean all the
fingerprints and oils from the gold surface before firing the appliance for the first time.  Use a glass
cleaner or vinegar and towel to remove the oils.  If not cleaned properly before lighting your first fire, the
oils can cause permanent markings on the gold plating.  After the gold plating is cured, the oils will not
affect the finish and little maintenance is required:  just wipe clean as needed.

CAUTION:  D

O

 

NOT

 

USE

 

POLISHES

 

WITH

 

ABRASIVE

 

AGENTS

.  T

HEY

 

WILL

 

SCRATCH

 

THE

 

PLATING

.

CHIMNEY CLEANING

Disconnect flue pipe from stove before cleaning chimney.  Otherwise residue can pile up on top of the baffle, and the
stove will not work properly.

ASH REMOVAL

Remove cold ashes (NEVER HOT) from the stove by shoveling them into a metal container with a tight-fitting lid.
Spraying cold ashes with water before shoveling them out of the stove will help eliminate ash flying around the firebox
and into the room.  Always treat ashes as if they contain hot coals, and store the container on a noncombustible floor
away from combustible material pending final disposal.  If unit is equipped with an ash removal system, see page 19 for
operating instructions.

FIREBRICK

The firebox of your Quadra-Fire stove is lined with high quality firebrick, which has exceptional insulating properties.
There is no need for use a grate; simply build a fire on the firebox floor of your stove.

OVERFIRING

Do not overfire.  Using flammable liquids or too much wood, burning trash in the stove, or allowing too much air into the
stove, may result in overfiring.  If the chimney connector or stove glows red or even worse, white, the stove is overfired.
This condition may ignite creosote in the chimney, which can be dangerous, possibly causing a house fire.  If you
overfire, immediately close the air controls and door, if open, to reduce the air supply to the fire.

Page 23

Содержание 3100 Series

Страница 1: ...unit to a chimney flue already serving another appliance 10 Comply with all minimum clearances to combustibles as shown in this manual for this appliance 11 Build fire on brick firebox floor Do not us...

Страница 2: ...h removal system installation 18 Ash removal system operating and cleaning 19 Operating instructions 20 Burning process 20 Primary and secondary air systems 20 Blower operating instructions 21 Operati...

Страница 3: ...3100 SAFETY LABEL found on back of stove Page 3 Manufactaured by Model Quadra Fire 3100 Serial No...

Страница 4: ...24 1 2 622mm 9 229mm 21 1 2 546mm 2 1 4 57mm 23 584mm DIMENSIONS Page 4 FIGURE 1b FIGURE 1a 20 1 2 521mm 9 229mm 24 1 2 622mm 2 1 4 57m m 23 584mm 26 3 8 670mm LEG MODEL PEDESTAL MODEL...

Страница 5: ...m 4 5 16 110m m 24 5 8 626m m 25 635m m 9 229m m 2 13 16 72m m 21 1 2 546m m STEP TOP LEG MODEL 13 11 16 348m m 4 5 16 110m m 26 5 8 676m m 23 7 8 606m m 2 13 16 72m m 24 5 8 626m m 20 1 2 521m m 21...

Страница 6: ...For installations with a preexisting class A chimney system a listed stainless steel chimney liner should be installed or the existing chimney examined by a chimney sweep for acceptable further use N...

Страница 7: ...all at least one smoke detector on each floor of your home to ensure your safety They should be located away from the heating appliance and close to the sleeping areas Follow the smoke detector manufa...

Страница 8: ...p of the stove after one hour of operation at each burn setting NOTE These are guidelines only and may vary somewhat for individual installations Your Quadra Fire stove was designed for and tested on...

Страница 9: ...the spaces where the chimney passes through floors and or ceiling Figure 5 The chimney must have a fire clay flue liner or equivalent with a minimum thickness of 5 8 16mm and must be installed with r...

Страница 10: ...hest point where it passes through the roof and at least 2 610mm higher than the highest part of the roof or structure that is within 10 3048mm of the chimney measured horizontally Figure 7 Remember t...

Страница 11: ...imbles must be strictly followed to assure the safety of the system Be sure to maintain the designated clearances to combustible materials A BRICK CHIMNEY THIMBLE ASSEMBLY Construction of the brick th...

Страница 12: ...mm long section of prefabricated listed solid pack chimney to use as a thimble Purchase a wall spacer trim collar and wall band that are manufactured to fit the chimney section you purchase Cut out a...

Страница 13: ...eyond the edge of the chimney flue lining Apply high temperature furnace cement to the end of the chimney section and install it over the connector through the wall band and through the wall spacer Ti...

Страница 14: ...ll an exterior chimney that runs up the outside of the residence Figure 13 This method of installation requires at a minimum a wall pass through device a wall support package insulated T section and r...

Страница 15: ...ved grounding device 6 Refer to clearance to combustibles section page 6 for listing to combustibles 7 Seal all wall floor inlets to prevent air or moisture penetration Check periodically to insure th...

Страница 16: ...w ash lip with two 20 mounting screws 2 Mount rear air intake cover plate with two mounting screws 3 Install each side cover with two 8 32 screws 4 Floor installation Cut a 3 76mm minimum hole in the...

Страница 17: ...tective pad or pallet 3 Bolt cover piece onto mounting brackets using outer two mounting holes 4 Slip washers onto bolts then bolt legs onto mounting brackets 5 Screw leg assembly onto adapter on bott...

Страница 18: ...ly stand stove up and place in desired location 8 Slip wooden decorative strips onto pedestal edges 9 Open door of stove and check to insure firebricks and kaowool blanket are in their proper location...

Страница 19: ...stem grate into the drawer below If there are large pieces in the ashes you can remove the grate before cleaning the ash into the drawer Be sure to replace the grate before operating the stove 3 Relea...

Страница 20: ...ained and not allowed to go out This will insure the cleanest possible fire If you are adjusting your stove for a low burn rate you should close down the air to the point where you can still maintain...

Страница 21: ...um of 15 minutes 2 Regulate burn rate heat output by using the secondary control center under ashcatcher The primary control on the right is mainly for initial start up reloading or high burns 3 Heat...

Страница 22: ...to allow adequate air flow between them 7 When ready to reload the stove add more logs Large logs burn slowly holding a fire longer Small logs burn fast and hot giving quick heat 8 Adjust the primary...

Страница 23: ...on removable film on inside of glass Overfiring voids warranty NOTE Replace with ceramic glass only CARE AND CLEANING OF PLATED SURFACES Clean 24 karat gold plated surfaces with vinegar or a glass cle...

Страница 24: ...rame pieces over the fiberglass tape on the edges of the glass Be sure glass is centered in the opening i e same space top and bottom left and right sides 6 Reinstall screws and glass tabs tight enoug...

Страница 25: ...ve the firebrick from the sides of the stove 4 With a 3 16 allen wrench remove the secondary combustion tube retainer bolts on the secondary air channel under the end of each tube NOTE Soak the bolts...

Страница 26: ...2 through 7 in reverse Be sure that the hole in the baffle is on its alignment pin on the rear shelf 7 Keep the baffle tilted as you lift it out the door BAFFLE REMOVAL AND INSTALLATION cont Page 26...

Страница 27: ...r this unit is adjusted at the factory and should not require further adjustment When the speed control is turned clockwise it will click on to high speed Turn the speed control clockwise to decrease...

Страница 28: ...S clips to the upper edge of the outer wall of the stove 3 Set top heat shield on stove and push down into S clips 4 Install chimney pipe through hole in top heat shield NOTE SEE PAGE 6 FOR REDUCED CL...

Страница 29: ...32 1911 Trim door 832 0031 Gold door 831 1670 Ash removal system SERVICE PARTS 832 0420 Kaowool blanket 832 3010 Firebox brick set clay 3100 Unibody 3100 ARS 832 0550 Individual brick clay 832 0360 Ba...

Страница 30: ...NOTES Page 30...

Страница 31: ...NOTES Page 31...

Страница 32: ...for any alteration to the unit which causes sooting that results in damage to the interior or exterior of the building in which this appliance is installed This warranty is void if the stove has been...

Отзывы: