background image

April 30, 2015   

 

 

           7046-191C  

 

 

 

         

                  7

27I-ACC

Model:

2700-I (ACC) Insert

Laboratory:

OMNI Test Laboratories, Inc.

Report No:

061-S-78-6.2

Type:

Solid Fuel Type, Listed Room Heater

Standard:

UL1482-1996 (RR2006) and ULC 
S628-93 and (UM) 84-HUD, Mobile 
Home Approved.

The Quadra-Fire 2700 Series Wood Insert (ACC) meets the 
U.S. Environmental Protection Agency’s crib wood emission  
limits for wood heaters sold after May 15, 2015. 

This wood heater needs periodic inspection and repair for 
proper operation. It is against federal regulations to operate 
this wood heater in a manner inconsistent with operating 
instructions in this manual.

•  Installation and use of any damaged appliance. 
• Modi

fi

 cation of the appliance.

•  Installation other than as instructed by Hearth & Home 

Technologies.

•  Installation and/or use of any component part not approved by 

Hearth & Home Technologies.

•  Operating appliance without fully assembling all components.
•  Operating appliance without legs attached (if supplied with unit).
•  Do NOT Over

fi

 re - If appliance or chimney connector glows, 

you are over

fi

 ring.

Any such action that may cause a 

fi

 re hazard.

Listing and Code Approvals

A.  Insert Certifi cation

NOTE:  Hearth & Home Technologies, manufacturer of 
this appliance, reserves the right to alter its products, their 
speci

fi

 cations and/or price without notice.

NOTE:  This installation must conform with local codes. In the 
absence of local codes you must comply with the UL1482, (UM) 
84-HUD and NPFA211 in the U.S.A. and the ULC S628-93 and 
CAN/CSA-B365 Installation Codes in Canada.

C.  Mobile Home Approved 

 • 

This appliance is approved for mobile home installa-
tions when not installed in a sleeping room and when 
an outside combustion air inlet is provided.

 • 

The structural integrity of the mobile home 

fl

 oor, ceil-

ing, and walls must be maintained. 

 • 

The appliance must be properly grounded to the frame 
of the mobile home with #8 copper ground wire, and 

chimney must be listed to UL103 HT or a listed UL-
1777 full length six inch (152mm) diameter liner must 
be used. 

 • 

Outside Air Kit, part OAK-ACC must be installed in a 
mobile home installation.

Improper installation, adjustment, alteration, service or 
maintenance can cause injury or property damage. 
For assistance or additional information, consult a quali

fi

 ed 

installer, service agency or your dealer.

Quadra-Fire is a registered trademark of Hearth & Home 
Technologies.

WARNING

Fire Risk.

Hearth & Home Technologies disclaims any 
responsibility for, and the warranty will be 
voided by, the following actions: 

B.  BTU & Effi ciency Specifi cations

D.  Glass Specifi cations

This stove is equipped with 5mm ceramic glass.  Replace 
glass only with 5mm ceramic glass.  Please contact your 
dealer for replacement glass.

EPA Certi

fi

 cation #: 760

EPA Certi

fi

 ed Emissions: 3.5 grams per hour

*LHV Tested Ef

fi

 ciency: 78.8 %

**HHV Tested Ef

fi

 ciency: 72.8 %

***EPA BTU Output: 10,600 to 16,600 / hr.

****Peak BTU/Hour Output: 38,600

Vent Size: 6 inches

Firebox Size: 1.85 cubic feet

Maximum Wood Length: 18 inches

Ideal Wood Length: 16 inches

Fuel Seasoned Cord Wood

* Weighted average LHV ef

fi

 ciency using Douglas Fir dimension-

al lumber and data collected during EPA emissions test.

**

Weighted average HHV ef

fi

 ciency using Douglas Fir dimen-

sional lumber and data collected during EPA emissions test.

***

A range of BTU outputs based on EPA Default Ef

fi

 ciency and 

the burn rates from the low and high EPA tests, using Douglas 
Fir dimensional lumber.

****

A peak BTU out of the unit calculated using the maximum 

fi

 rst 

hour burn rate from the High EPA Test and the BTU content of 
cordwood (8600) times the ef

fi

 ciency.

Содержание 27I-ACC

Страница 1: ... followed exactly a fire may result causing property damage personal injury or death Do not store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance Do not overfire If heater or chimney con nector glows you are overfiring Overfiring will void your warranty Comply with all minimum clearances to combustibles as specified Failure to comply may cause ...

Страница 2: ...unit to a chimney serving another appliance DANGER Risk of electrical shock Disconnect power supply before servicing Route power cord away from unit Do not route cord under or in front of appliance Electrical Rating 115 VAC 63 AMPS 60 Hz Do not use grate or elevate fire Build wood fire directly on firebrick Do not overfire If heater or chimney connector glows you are overfiring Operate only with d...

Страница 3: ...tible Non combustible Materials 9 E Seasoned Wood 9 F Burning Process 10 G Automatic Combustion Control ACC 11 H Air Controls 11 I Burn Rates and Operating Efficiency 12 J Correct Baffle Blanket Placement 13 K Building A Fire 14 L Wood Fuel 15 M Operating the Blower Control Box with Snap Disc 16 N Blower Operating Instructions 16 O Clear Space 17 P Frequently Asked Questions 17 Q Opacity Smoke 17 ...

Страница 4: ...ction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warranty period for parts and labor for covered ...

Страница 5: ...191C 5 27I ACC WARRANTY CONDITIONS This warranty is void if LIMITATIONS OF LIABILITY 8 K N N OQ R U Z 8 88 U 8 U Q 8 N N Q Z R N U Q 8 R Z N N 88 N U Q 8 N O K WARRANTY EXCLUSIONS N Z N _ q _ q _ q _ q _ q _ q _ q _ q _ q ...

Страница 6: ...Fire Close and securely latch the door after the fire has started and after refueling to prevent Spillage of smoke flame and carbon monoxide Spillage of sparks coals and logs Over firing DO NOT leave the stove unattended with the door open Starting a fire may not require an open door for draft The air control should supply adequate draft 10 Pieces of Newspaper 10 20 Pieces of Dry Kindling and a Fe...

Страница 7: ...ion air inlet is provided The structural integrity of the mobile home floor ceil ing and walls must be maintained The appliance must be properly grounded to the frame of the mobile home with 8 copper ground wire and chimney must be listed to UL103 HT or a listed UL 1777 full length six inch 152mm diameter liner must be used Outside Air Kit part OAK ACC must be installed in a mobile home installati...

Страница 8: ... until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as appliance Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable materials away HOT SURFACES Glass and other surfaces are hot during operation AND cool down...

Страница 9: ...NOT Use flammable liquids Overload with wood Burn trash or large amounts of scrap lumber Permit too much air to the fire Use of processed solid fuel fire logs WARNING Fire Risk 1 Symptoms of Over Firing Symptoms of over firing may include one or more of the fol lowing Chimney connector or appliance glowing Roaring rumbling noises Loud cracking or banging sounds Metal warping Chimney fire 2 What To...

Страница 10: ...shing the flue draft not evaporating the mois ture out of wet unseasoned wood resulting in wasted heat 2 Second Stage In the secondary stage wood gives off flammable gases which burn above the fuel with bright flames During this stage of burning The flames must be maintained and not allowed to go out to ensure the cleanest possible fire If the flames tend to go out it is set too low for your burn ...

Страница 11: ... Air Control all the way back until it stops and then pull forward to the front of the appliance until it stops Figure 11 1 The front air channel opens and allows air to enter the front of the appliance for approximately 20 25 minutes The front air channel gradually shuts down until it is com pletely closed at the end of the 20 25 minutes The fire is now controlled by the air supplied by the Burn ...

Страница 12: ... setting by following the burn rate instructions below 2 High Burn Rate Maximum Heat Raise the Burn Rate Air Control all the way up until it stops top marker to a fully open position Push the Start Up Air Control all the way back until it stops and leave it there This setting over rides the timer system ACC so you must monitor the fire closely while in this setting 3 Medium High Burn Rate 15 000 t...

Страница 13: ...acket Ceramic Blanket and Baffle Board MUST be in contact with the back of the firebox and even with each other in the front Figure 13 1 Correct Baffle and Blanket Positions Figure 13 2 Incorrect Baffle and Blanket Positions Improper baffle placement may cause Overheating of firebox Overheating the chimney Baffle must be placed properly see instructions Replace baffle if damaged or missing WARNING...

Страница 14: ...nough to keep each other hot but far enough away from each other to allow air flow between them 8 Close door and latch securely rotate handle clockwise 9 Set the Burn Rate Air Control and activate the timer sys tem ACC NOTE Build fire on brick firebox floor Do NOT use grates andirons or other methods to support fuel It will adversely affect emissions Odors and vapors released during initial operat...

Страница 15: ... sides Store wood under cover to prevent water absorption from rain or snow Avoid covering the sides and ends completely Processed Solid Fuel Fire Logs NOT permitted for use in this appliance WARNING Fire Risk DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE NAPTHA OR ENGINE OIL DO NOT USE CHEMICALS OR FLUIDS TO START A FIRE Do NOT burn treated wood or wood with salt driftwood May generate...

Страница 16: ...w Burn Setting Burn Rate Air Control is closed Leave the blower off until the burn is well established i e 30 minutes NOTE For burn settings 3 to 5 the Start up Air Control needs to be pushed in Open then pulled forward to acti vate the Automatic Combustion Control ACC NOTE For maximum efficiency and lowest emissions when operating the blower in either the automatic or manual setting for the low a...

Страница 17: ...d contracting as it heats up and cools down similar to the sound produced by a furnace or heating duct This noise does not affect the operation or longevity of the appliance Whirring sound The blower may produce a whirring sound which increases in volume as the speed is increased Contact your dealer for additional information regarding operation and troubleshooting Visit www quadrafire com to find...

Страница 18: ...ng the chimney The creosote or soot should be removed with a brush specifically designed for the type of chimney in use Clean out fallen ashes from the firebox It is also recommended that before each heating season the entire system be professionally inspected cleaned and repaired if necessary WARNING Risk of Fire Do not use chimney cleaners or flame colorants in your appliance It will corrode you...

Страница 19: ...ntrol and Start Up Air Control all the way open for 15 20 min utes should remove the built up coating CAUTION Handle glass assembly with care Glass is breakable Avoid striking scratching or slamming glass Avoid abrasive cleaners Do not clean glass while it is hot F Inspect Firebrick Frequency After each ash removal By Homeowner Replace the firebrick if they become crumbly and or if there is a 1 4 ...

Страница 20: ...ting To test place a dollar bill between the stove and door and then shut the door If you can pull the dollar out remove one washer from door handle behind latch cam and try again If you can still pull it out replace the door gasket Check the glass frame for loose screws to prevent air leakage Check glass for cracks WEEKLY or After Every 25 Loads of Wood Check the door latch for proper adjustment ...

Страница 21: ... adequate vent height refer to Chimney Height Section Open window below the appliance towards the wind Wood condition is too wet too large Use dry seasoned wood refer to Seasoned Wood Section Bed of coals not established before adding wood Start with paper kindling to establish bed of coals refer to Building a Fire Section Flue blockage such as birds nests or leaves in termination cap Have chimney...

Страница 22: ...he appliance Quadra Fire appliances are equipped with ceramic super heat resistant glass which can only be broken by impact or misuse WARNING Risk of Fire or Injury Use only glass that is specified in the manual DO NOT replace with any other material Glass breakage will occur CAUTION Handle glass with care Inspect the gasket to ensure it is undamaged Do NOT strike slam or scratch glass Do NOT oper...

Страница 23: ...g to the appliance Figure 23 1 Snap Disc Location Figure 23 2 Remove Bolts and Slide Blower Assembly Out Snap Disc Location Snap Disc Figure 23 3 Door Handle for Arched Door D Door Handle Assembly 1 Install washer on door handle shaft 2 Slide door handle through door 3 Install second washer s as shown in Figure 23 3 4 Install key in groove 5 Align groove in latch cam with key slide latch cam over ...

Страница 24: ... channel assembly 3 Once the baffle protection cover has been removed pull the baffle boards and ceramic blanket forward about 1 inch 25mm and then overlap the baffles about 1 2 inches 25 51mm Figure 24 1 4 Slide the tube channel assembly to the left as far as it will go and lower the right side Remove the baffle boards and ceramic blanket together Figure 24 2 5 Re install in reverse order Be sure...

Страница 25: ...min utes before trying to remove them 4 Slide the tube channel assembly all the way to left until it is off the threads Drop the right side down then slide the assembly back to right Figure 24 1 on page 24 5 The ceramic blanket and both baffle boards can be removed at the same time you remove the tube channel assembly 6 When the tube channel assembly is free of the left side support rotate clockwi...

Страница 26: ...26 7046 191C April 30 2015 27I ACC 6 Reference Materials Date of Service Performed By Description of Service A Service Maintenance Log ...

Страница 27: ...Accessories Service Parts R 27i ACC Beginning Manufacturing Date Nov 2009 Ending Manufacturing Date Active Wood Stove Insert Advanced Combustion Control Part number list on following page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 23 22 21 20 19 04 15 ...

Страница 28: ...ram Qty 2 Req 6 3 Brick 7 3 8 x 4 1 2 x 1 25 Angle Cut see diagram Qty 3 Req 6 4 Brick 8 1 8 x 4 1 2 x 1 25 Angle Cut see diagram Qty 2 Req Brick Uncut Pkg of 1 832 0550 Pkg of 6 832 3040 7 Blower Housing Assembly SRV7046 003 7 1 Blower Replacement SRV7044 210 Y 7 2 Snap Disc 1 Convection Blower SRV230 0470 Y 7 3 Filler Plate SRV7046 180 7 4 Logo Quadra Fire Pkg of 10 7000 649 10 7 5 Wire Harness ...

Страница 29: ...0 832 0860 Y Door Hardware SRV7044 041 9 Door Assembly Black DR 27BK FH No longer available DR 27GD Nickel Trim DR 27NL FH 9 1 Glass Frame Set 832 1540 9 2 Door Glass Assembly 17 00 W x 9 13 H 7000 011 Y 9 3 Hinge Pins 1 2 Gold 832 0250 Nickel 430 5320 Black 7000 606 2 9 4 Trim Ring Door No longer available 430 2702 No longer available 430 5350 9 6 Door Handle Assembly Fiber SRV7033 071 Spring 832...

Страница 30: ...ection Channel SRV7046 165 Y 13 BafÀe Board Pkg of 2 SRV7046 119 Y 14 Ceramic Fiber Blanket 1 2 Thick 832 3390 Y 15 Combustion Cover Bottom SRV7046 144 16 Combustion Air Assembly SRV7046 009 Y Knob Pkg of 2 32284 2 Y Timer Only Replacement Assembly SRV480 1940 Y 17 Timer Door Assembly SRV7044 020 Y Door Gasket 7033 282 Y 18 Burn Rate Control Assembly SRV7046 007 Y 19 Combustion Cover Assembly SRV7...

Страница 31: ...omponent Pack SRV7044 036 Outside Air Cover Plate SRV7046 182 U Clip Pkg of 4 7000 137 4 Surround Trim Assembly 43 X 31 Black TRIMKIT 4331 BK No Longer Available TRIMKIT 4331 GD Nickel Trim TRIMKIT 4331 NL Surround Trim Assembly 51 X 34 Black TRIMKIT 5134 BK No Longer Available TRIMKIT 5134 GD Nickel Trim TRIMKIT 5134 NL Bracket L Trim Pkg of 2 832 0840 FASTENERS Avk Rivnut Repair Kit 1 4 20 3 8 1...

Страница 32: ...eration DO NOT DISCARD Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer log onto www quadrafire com We recommend that you record the following pertinent information for your heating appliance Date purchased installed Serial Number Location on appliance Dealership purchased from Dealer phone Notes CONTACT INFORMATION This produc...

Отзывы: