manualshive.com logo in svg
background image

 

www.avsl.com

                                                                                                        160.448UK Manual 

Rear Panel: 

 

Wired Digital Control Panel: 
 
 

 
FUNC: 

Press to scroll through menu options 

 

 

 

 

 

TIMER: 

Press to set up the fog timer function 

 

 

 

 

 

UP:

 Press to increase the current menu value 

 

 

 

 

 

START/STOP: 

Press to start/stop continuous fog 

 

 

 

 

 

DOWN: 

Press to decrease current menu value 

 

 

 

 

 

MANUAL:

 Press and release for fog on demand 

 
 
 
 
Setting Up: 

 

1.

 

Unpack the Stratus-1200 unit. 

2.

 

Unscrew the top cap of the tank and remove to fill with fog fluid. 

3.

 

Replace the bottle and screw the cap securely, making sure that the pipe is fed down 

to the bottom of the bottle to ensure a consistent flow of fluid. 

Содержание STRATUS-1200

Страница 1: ...y delivers a ground hugging flowing mist from standard fog fluid and water perfect for stages theatres and themed events The main unit has a removable fluid tank and easy access water reservoir with drain tap and can be operated by a wired digital control panel separate RF remote or 2 channel DMX connection if required Produces an impressive ground hugging mist effect Works using only standard fog...

Страница 2: ... parts inside do not open the case 5 Allow the unit to acclimatise to room temperature before operating 6 The Stratus 1200 has a built in fluid container and reservoir so should be operated in an upright position Ensure that the unit is positioned on a stable non slip surface Safety and Cleaning 1 Check for correct mains voltage and condition of IEC lead before connecting to mains 2 This unit must...

Страница 3: ...alue START STOP Press to start stop continuous fog DOWN Press to decrease current menu value MANUAL Press and release for fog on demand Setting Up 1 Unpack the Stratus 1200 unit 2 Unscrew the top cap of the tank and remove to fill with fog fluid 3 Replace the bottle and screw the cap securely making sure that the pipe is fed down to the bottom of the bottle to ensure a consistent flow of fluid ...

Страница 4: ...on Content Heating status Warming up Unit is warming up please wait Ready to fog Unit is ready to use Manual volume adjust Set 1 100 Set manual fog output low to high Interval Set 1 900 Set continuous fog intervals low to high Duration Set 1 200 Set continuous fog duration Volume Set 1 100 Set continuous fog output low to high Wind Set 1 100 Set fan speed low to high DMX512 Set 1 512 Set required ...

Страница 5: ...s may be blocked or continuous mode Check that output is not set to zero on the control panel Check that output is not switched off on the key fob remote If blocked clean with fog machine cleaner distilled water Check that if DMX mode is selected the DMX channel is correct In DMX mode check that fog output is not set to zero Fog output from unit Ensure you are using the correct fog fluid for the u...

Отзывы: