background image

 

 

154.037UK User Manual 

DMX Value Reference 

 

Channel 

DMX Value 

Function 

CH1 

001 - 255 

Master dimming for CH5, CH6, CH7 & CH8 (0-100%) 

CH2 

001 - 255 

Strobe (slow to fast) 

 
 
CH3 

001 - 050 

No Function 

051 - 100 

Colour Jump 

101 - 150 

Gradual colour Change 

151 - 200 

Colour Fade 

201 - 255 

Sound activation 

CH4 

001 - 255 

Speed Control for CH3 

CH5 

001 - 255 

RED 0-100% (Ensure CH1 has DMX value of +021) 

CH6 

001 - 255 

GREEN 0-100% (Ensure CH1 has DMX value of +021) 

CH7 

001 - 255 

BLUE 0-100% (Ensure CH1 has DMX value of +021) 

CH8 

001 - 255 

WHITE 0-100% (Ensure CH1 has DMX value of +021) 

 

 

Troubleshooting 

 

No power (mains) 

Check mains voltage is correct and outlet is switched on 
Check IEC lead and fuse (if fuse continually blows, refer to your dealer) 

No LED display 

Press any control panel button and check LED setting in menu 

No light output 

Check control panel mode settings 
Check DMX settings from controller (dimmer levels, blackout etc.) 

No strobe output 

Check strobe settings on control panel or from DMX controller 

Unresponsive to 
DMX  

Check that unit is in DMX mode 
Check DMX controller is not set to black out 
Check DMX controller is on correct fixture/page 
Check master dimmer value 
Check correct DMX address is set 
Check DMX connection and leads 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

   

  

  

This product is classed as Electrical or Electronic equipment and should not be disposed with other household or commercial waste 

at the end of its useful life. The goods must be disposed of according to your local council guidelines. 

 

Errors and omissions excepted. 

 

Copyright© 2017 AVSL Group Ltd. 

Содержание PL-COB6Q

Страница 1: ...t risk of fire or electric shock do not expose unit to rain or moisture In case of accidental spillage on the unit disconnect the main and allow unit to dry completely Have unit check by professional personnel to ensure safety before further use Contents PAR Can unit with hanging bracket mains lead and manual Please check all contents are complete before use return to your dealer if anything is mi...

Страница 2: ...tatic green see ST for Strobe speed Static blue see ST for Strobe speed Static pure White see ST for Strobe speed Static yellow see ST for Strobe speed Static cyan see ST for Strobe speed Static purple see ST for Strobe speed Static full white see ST for Strobe speed Colour change see SP for speed setting Colour Scroll see SP for speed setting xx MUST BE TO AVOID STROBE EFFECT ON STATIC COLOUR SET...

Страница 3: ...strobe effect will flash in the colour s of the auto program Sound to light To select the sound to light function press Menu until the display shows xx or xx where xx is a number press the up down buttons until or is displayed and press enter to select is a sound activated colour change and is a sound activated strobe effect Master slave mode To use in Master Slave mode connect PL COB6Q units with...

Страница 4: ... if fuse continually blows refer to your dealer No LED display Press any control panel button and check LED setting in menu No light output Check control panel mode settings Check DMX settings from controller dimmer levels blackout etc No strobe output Check strobe settings on control panel or from DMX controller Unresponsive to DMX Check that unit is in DMX mode Check DMX controller is not set to...

Отзывы: