background image

USER MANUAL

 

 

9

channel is used solely for a 0% to 100% switch. Before applying power to a fixture, 

check that the source voltage matches the fixture’s requirement. 

 

The unit is supplied with a power plug appropriate to its voltage and 

destination. Should any other connections be required they must be 

carried out with the following configuration. 

 
 
 
 
 
 
 
 
 
 
 
 
DMX-512 connection between fixtures       
 

The fixture is equipped with 2-pin XLR sockets for DMX input and output. The 

sockets are wired in parallel. Only use a shielded twisted-pair cable designed for 

3-pin XLR-plugs and connectors in order to connect the controller with the fixture 

or one fixture with another. 

 

Occupation of the XLR-connection       

 

 
 
 
 

Caution: 

At the laser fixture, the DMX-cable has to terminated with a 

terminator. Solder a 120 Ohm resistor between Signal (-) and 

Signal (+) into a 3-pin XLR-plug and plug and plug it in the 

DMX-output of the last fixture.   

 

Cable(EU) 

Cable(US) 

Pin 

International

Brown Black  Live 

Liht blue 

White 

Neutral 

Yellow/Green

Green Earth 

Содержание LS-OPAL

Страница 1: ...t laser system safety and operation information Read and understand all instructions prior to powering on laser unit the first time to avoid laser eye injury and to avoid breaking the law Keep this ma...

Страница 2: ...aser incident or damage Prevent damage or injury from incorrect operation Laser safety warming labels To protect the environment recycle packing material wherever possible The projector is for indoor...

Страница 3: ...parts inside the unit Do not open the housing or attempt any repairs yourself In the unlikely event your unit may require service please contact the dealer nearest to you Caution Use of controls or a...

Страница 4: ...ucts split the laser into hundreds of beams or laser beam is scanned out in high speed that an individual laser beam is safe for eye exposure This laser product uses dozens of milliWatts of laser powe...

Страница 5: ...ged or open or if optics appear damaged in any way z Never open the laser housing The high laser power levels inside of the protective housing can start fires burn skin and will cause instant eye inju...

Страница 6: ...ISSION DATA As measured under IEC measurement conditions for classification Laser Classification Class 3B Green Laser Medium DPSS Nd YVO4 532nm Red Laser Medium LD GaAIAs 650nm typical Blue Laser Medi...

Страница 7: ...any unauthorized modification to the device z Please consider that damages caused by manual modifications to the devise are not subject to warranty z Never let the power cord come into contact with o...

Страница 8: ...he installation spot please make sure that the device is not exposed to extreme heat moisture or dust There should not be any cables lying around You endanger your own and the safety of others z The m...

Страница 9: ...the fixture be returned in the original factory box and packing What is included The carton or flight case contain following items Power Supply To determine the power requirements for a particular fi...

Страница 10: ...d with 2 pin XLR sockets for DMX input and output The sockets are wired in parallel Only use a shielded twisted pair cable designed for 3 pin XLR plugs and connectors in order to connect the controlle...

Страница 11: ...Solder a 120 Ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a 3 pins XLR plug and plug it in the DMX output of the last fixture z Connect the fixture together in a daisy chain by XLR plug cabl...

Страница 12: ...priate for safe and effective mounting are easily sourced from your lighting vendor International laser safety regulations require that lasers must be operated in the fashion illustrated below with a...

Страница 13: ...has to make sure that safety relating and machine technical installations are approved by an expert before taking into operation for the first time and after changes before taking into operation anoth...

Страница 14: ...zed modification to the device Features z STABLE TE COOLED LASER DIODE CNI z HIGH SPEED 30KHz SCANNER z 2 x AUTO SHOW 2 x MUSIC SHOW z 128 ANIMATED GRAPHIC SHOW PATTERNS z HUNDRES PREPROGRAMED BEAM EF...

Страница 15: ...ic mode and green is Audio activated music mode 23 Laser output Laser output aperture 24 WARNING LABEL laser aperture 25 WARNING LABEL Caution Class 3B laser 26 LASER WARNING SIGN warns against a pote...

Страница 16: ...n use 4 Urgent and safe switch Switch off the laser manually if error occurs 5 DMX output 3PIN Female XLR port using for DMX 6 DMX input 3PIN Male XLR port using for DMX 7 Cooling fan Cooling and neve...

Страница 17: ...djust the audio respond sensitivity 14 MIC Microphone Turn the knob to adjust the sound activated sensitivity 15 ILDA INPUT Standard ILDA DB25 Input 16 ILDA OUT Standard ILDA DB25 Output through 17 R...

Страница 18: ...5 seconds after the unit is powered on Operating Mode Attention Once after every power on laser the VERSION and MANUFACTURE INFORMATION will be shown in LCD monitor of rear panel When laser is powere...

Страница 19: ...w which is better for DISCO z Press ENTER to confirm the laser to show the present mode at the next operation AUTO SHOW 2 z Press FUNC to enter MODE OPTION z Till to AUTO SHOW 2 shown on LCD monitor T...

Страница 20: ...on LCD monitor The laser is set at MUSIC SHOW 2 standalone mode and it will play the preprogrammed show until next setting is changed MUSIC SHOW 2 is slow and soft show which is better for MUSIC BAR...

Страница 21: ...Mirror Setting z Press FUNC to enter MODE OPTION z Till to MIRROR shown on LCD monitor z Press UP DOWN to change scanned world mirror UP is for Y direction mirror setting and DOWN is for X direction...

Страница 22: ...card has not connect In fact this is an easy problem As long as you connect them It can control this unit DMX Channels Chart DMX CHANNEL 1 CHART CHANNEL VALUE DESCRIPTION CH 1 MODES 000 031 AUTO SHOW...

Страница 23: ...ow 128 159 Green 160 191 Cyan 192 223 Blue 224 255 Purple CH6 COLOR LOOP 000 005 Pattern Original Fixed Color 006 255 Color Loop from slow to fast CH 7 CLIPING 000 Full pattern without clipping 001 12...

Страница 24: ...to fast anticlockwise moving on X axis CH 13 Y AXIS MOVING 000 127 Y axis fixed position 128 191 Slow to fast clockwise moving on Y axis 128 255 Slow to fast anticlockwise moving on Y axis DOUBLE PATT...

Страница 25: ...pattern rolled 128 191 Slow to fast clockwise rolling 192 255 Slow to fast anticlockwise rolling CH 11 Z AXIS ROTATING 000 127 0 359 fixed pattern rotated 128 191 Slow to fast clockwise rotating 128...

Страница 26: ...000 127 0 359 fixed pattern rolled 128 255 Slow to fast clockwise rolling 192 255 Slow to fast anticlockwise rolling CH 21 Y AXIS ROLLING 000 127 0 359 fixed pattern rolled 128 191 Slow to fast clock...

Страница 27: ...CTOR 032 063 White 064 095 Red 096 127 Yellow 128 159 Green 160 191 Cyan 192 223 Blue 224 255 Purple CH 6 COLOR LOOP 000 005 Pattern Original Fixed Color 006 255 Color Loop from slow to fast CH 7 CLIP...

Страница 28: ...USER MANUAL 27 PATTERN LIST IN CHANNEL 3 4 DMX 1 2 3 4 5 6 7 8 000 015 016 031 032 047 048 063 064 079 080 095 096 111 112 127 128 143 144 159 160 175 176 191 192 207 208 223 224 239 240 255...

Страница 29: ...rom overheat the cooling fans if any and ventilation openings should be cleaned monthly z The interior of the device should be cleaned annually using a vacuum cleaner or air jet z The cleaning of inte...

Страница 30: ...ser effect power is very weak 1 Wait for at least 30 minutes to warm up in low temperature 2 Clean the scanner mirror with alcohol 3 Clean the aperture glass with alcohol 4 Check whether it is in DMX...

Страница 31: ...s Measurement N Weight AC100 240V 50 60Hz 250V 2A Slow Blow 20mm Glass 60W 25 Audio Sound Activated 350mW 650nm Red CW 60mW 532nm Green CW 50mW 473nm Blue CW Class 3B EN60825 1 2007 10 40 3 pins XLR M...

Отзывы: