QTS QTS-CLX-PVX Скачать руководство пользователя страница 1

 

QTS-CLX-PVX 

PROVOX

®

 

Module

 

 
User Manual 
 

 

 

 

 

 

 

Содержание QTS-CLX-PVX

Страница 1: ...QTS CLX PVX PROVOX Module User Manual...

Страница 2: ...s not assume responsibility or liability to include intellectual property liability for actual use based upon the examples shown in this publication Throughout this manual we use notes to make you awa...

Страница 3: ......

Страница 4: ...ion 4 Determine Module Slot Location 4 Insert the Module in the Chassis 5 Replacing a Module 6 Cabling and Termination 7 Software Installation 7 SUMMARY OF OPERATIONS 8 IMPORTANT CONSIDERATIONS 9 CONF...

Страница 5: ...iguration Signature 21 Aliases 21 ACCESSING I O DATA 23 Required Connections 23 Data Updates 23 Discrete Data 23 Analog Data Format 23 Diagnostic Data 25 USING MONITOR MODE FOR MIGRATION 28 TROUBLESHO...

Страница 6: ...Page iv QTS CLX PVX September 2009 APPENDIX CLXPVXCFG 33 APPENDIX CONFIGURATION FILE FORMAT 35 SPECIFICATIONS 38 QTS CLX PVX ControlLogix Module 38 SUPPORT 39 WARRANTY 40...

Страница 7: ...tor mode the QTS CLX PVX sends PROVOX I O input and output data to input and status input data in the ControlLogix It cannot transmit on the bus In master mode the ControlLogix sends output data to th...

Страница 8: ...to the module saves and opens configuration files exports aliases for use in your RSLogix 5000 application Firmware Update The module firmware can be updated using the Windows utility supplied see pa...

Страница 9: ...s hardware If the bus transmitter is on longer than 150 of the longest frame time the jabber inhibit forces the transmitter off and generates a fatal error see page 31 with error code D0 In master mo...

Страница 10: ...touch circuit components inside the module If available use a static safe work station When the module is not in use keep it in its static shield packaging Prepare the Chassis for Module Installation...

Страница 11: ...n you insert or remove the module while backplane power is on an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or the area is...

Страница 12: ...le with an identical one and you want to resume identical system operation you must install the new module in the same slot run the configuration program and download the appropriate configuration to...

Страница 13: ...There should be two and only two terminators on each bus Refer to the following Emerson documents for details on cabling section 3 8 of Installing and Maintaining the SRx Controller Family PN8 0 CL664...

Страница 14: ...the default 15 3 Connect the module to the Control I O bus 7 4 Autoconfigure the module from the PROVOX Control I O bus 16 5 Configure the module in RSLogix 5000 10 6 Decide if you are going to use mo...

Страница 15: ...onnection to the ControlLogix processor is lost This is so that I O on the bus does not time out on the Control I O bus data is passed only when it changes In monitor mode the QTS CLX PVX sees only da...

Страница 16: ...cannot transmit on the bus You should always access data using the aliases generated by the configuration program Module Configuration Configure the module as a Generic module in RSLogix 5000 The same...

Страница 17: ...gix 5000 displays the New Module dialog box 5 Assign the module a Name and optionally a Description 6 Set the Comm Format to Data INT With Status 7 Set the Slot to match the slot number of the QTS CLX...

Страница 18: ...ControlLogix processor over Ethernet or ControlNet it may be necessary to increase the RPI as the intermediate network may not have sufficient bandwidth to support faster updates small RPIs I O Data M...

Страница 19: ...cal Solutions Product Type 12 Product Code 1052 Monitor 1051 Master Revision depends on firmware Serial Number depends on module RSLinx Properties To use the Windows utility programs you must have RSL...

Страница 20: ...ode Map I O data to ControlLogix scheduled connections Save and load configuration files Download and upload configurations Set the RSLinx path to the QTX CLX PVX module Export aliases for I O data fo...

Страница 21: ...each module are unique TIP Use the same name that you assign the module in RSLogix 5000 to make it easy to associate aliases with the module You can use the name of the controller you are monitoring...

Страница 22: ...ge The ControlLogix controller with the connection to the module must be in program mode when you change mode If the processor is in run mode the following message appears The QTS CLX PVX displays the...

Страница 23: ...e PROVOX master The QTS CLX PVX captures the configuration data the master sends out and passes it to the configuration program which analyzes it and builds the tree 4 Download the captured configurat...

Страница 24: ...one of these limits without exceeding the maximum of 64 cards In monitor mode you will have to remove some cards from the configuration or use two QTS CLX PVX modules as monitors In master mode you ca...

Страница 25: ...puts path S Monitor Mode PROVOX inputs AI DI are mapped to ControlLogix inputs path I PROVOX outputs AO DO are mapped to ControlLogix status inputs path S Diagnostics are mapped to ControlLogix inputs...

Страница 26: ...VOX reset download the configuration to the module Saving a Configuration File To save a configuration to disk select File Save or File Save As Opening a Configuration File To open a configuration fil...

Страница 27: ...are identical Aliases The configuration tool creates aliases for I O data that can be exported and imported into RSLogix 5000 You should write programs in terms of these aliases rather than using abso...

Страница 28: ...t the alias file TIP If you have changed mode on the QTS CLX PVX delete any aliases you previously imported into RSLogix 5000 before you import the new aliases Alias Format ClxPvxCfg builds each alias...

Страница 29: ...he module is not connected to the bus will not be captured Discrete Data Use the aliases created by ClxPvxCfg to access discrete data to ensure that you are using the correct address and bit Analog Da...

Страница 30: ...convert 1940 hex first note that the number is positive high bit clear Convert the whole number part 19 hex to 25 decimal The fractional part is 40 hex 64 decimal Convert it to a fraction 64 256 25 an...

Страница 31: ...ut data contain a table that shows which card files have communication problems on either the primary or secondary bus The first word at offset 0 corresponds to the primary The second word at offset 1...

Страница 32: ...ckets received on primary channel StatPrimAbortErr Number of abort packets on primary channel StatPrimNoiseErr Number of error packets caused by noise on primary channel StatPrimFrameErr Number of pac...

Страница 33: ...LenErr Number of short packets received on primary channel StatPrimRxTimeOut Number of packet timeout errors on primary channel StatSecTxGood Number of good packets sent on secondary channel StatSecRx...

Страница 34: ...uts and timing disconnect the PROVOX controller and switch the QTS CLX PVX module to master mode Export aliases from ClxPvxCfg in master mode and import them into RSLogix 5000 The names for the output...

Страница 35: ...t of bus errors causes the LED to stay red for longer than 1 second Yellow One or more configured cards is offline can t be reached via primary or secondary links Green All configured cards are online...

Страница 36: ...If a fatal error occurs clear the fatal error save the file and contact Technical Support QTS CLX PVX Module 4 Character Display The 4 character display shows the firmware in the module either CLX PV...

Страница 37: ...ition The module stops running turns all three LEDs red and displays the fatal error number on the 4 character display The module also records its state at the time the fatal error occurred in a log T...

Страница 38: ...de To update the firmware set the mode to match the firmware already loaded in the module Set Module Mode uses the firmware files qtf in the same directory as ClxPvxCfg exe The configuration program d...

Страница 39: ...d Exit Exit ClxPvxCfg Actions Menu Upload Config Upload a configuration from the QTS CLX PVX to ClxPvxCfg Download Config Download a configuration from ClxPvxCfg to the QTS CLX PVX module Start Auto C...

Страница 40: ...e Edit Module Properties Change module name Auto allocate CLX Addressing see above Change Module Mode see above Right click on card Delete Card Delete a card from the configuration Also clears all Con...

Страница 41: ...aster 54cd3512 monitor Options the starting card in each of the four scan segments Cfg Id the hexadecimal configuration ID calculated by ClxPvxCfg exe This is followed by card definitions for each car...

Страница 42: ...r channel starting at channel 1 Possible channel types are Channel Type Value Hex Value Decimal DO_MOMENTARY_TYPE_CODE 04 4 DO_LATCHING_TYPE_CODE 06 6 DI_CHANNEL_TYPE_CODE 05 5 PCI_CHANNEL_TYPE_CODE 1...

Страница 43: ...m is an array of 16 bytes containing any channel parameters Input Copy Table and Output Copy Table define where the input and output data for the card are copied to or from in the ControlLogix The lay...

Страница 44: ...chassis Function ControlLogix module for PROVOX Control I O bus Maximum Backplane Current Load 675 mA 24VDC and 5 mA 5 1VDC from I O chassis backplane Power dissipation 20W maximum Environmental Cond...

Страница 45: ...Contact our worldwide Sales or Technical Support teams directly by phone or email Asia Pacific 603 7724 2080 asiapc prosoft technology com Europe Middle East Africa 33 0 5 34 36 87 20 Europe prosoft t...

Страница 46: ...ich original identification marks have been removed or altered This Limited Warranty also will not apply to interconnecting cables or wires consumables nor to any damage resulting from battery leakage...