441 Industrial Road, London, Ontario L5V 1T6 Canada
www.qtekdesign.com
M000001 QTEK DStacker GS2 -‐ INSTALLATION OPERATIONS MANUAL May 2015
Page 6 of 6
MAINTENANCE INSTRUCTIONS:
D
AILY
:
Clean the floor in the DStacker, removing any pallet debris or dirt. This will ensure the
pallets rest evenly on the floor.
W
EEKLY
:
Verify that the PCM is functioning properly.
Once the pallet stack is below the PCM’s lower extremity, manually push the left PCM into its
side recess. The PCM should push back to its starting position. Next, perform test on right
side.
S
EMI
A
NNUALLY
:
Test each of the four (4) latch spring mechanisms.
Remove the pallet stack (as per Section C) from the DStacker chamber. Manually push one
of the four (4) latches inward. The latches should offer some resistance and will return to
the outward position once released. Perform the test on the other three latches individually.
If the latch does not return, check the integrity of the spring mechanism by removing the
side or back interior metal panel.
Lubricate the two (2) counterweight chains with a 30-‐wt lubricating oil. Access the chains by
removing the exterior back panel.
Lubricate the two rear and two front cam follower tracks with 30-‐wt lubricating oil.
Check hydraulic oil reservoir level. If oil is below MIN level indicator, replenish to the MAX
level indicator mark.
PLEASE NOTE:
Arctic Supreme 32 Hi-‐Performance hydraulic fluid is to
be used in the DStacker GS.