SITE REQUIREMENTS
F
ACILITY
S
UPPLIED
:
1) Electrical Requirements: 120VDC or Solar Option
Pneumatic Requirements:
None
2) The installation site must have a level concrete surface otherwise the machine’s functionality
could be compromised.
3) The site will require a minimum headroom clearance of 16 feet from the floor.
4) The machine will require a minimum clearance around the unit as follows;
Left side, right side and rear of unit – 24” minimum
Front access clearance – 96” minimum
5) A forklift (minimum 5000 lbs lifting capacity) with a vertical reach of 12 feet”.
T
OOLS
R
EQUIRED
:
Hammer drill with a 3/4” & 5/8” drill bit capable of drilling a minimum depth of 6”
Heavy hammer
Set of wrenches (1/2", 9/16” and 3/4")
Utility knife
Step Ladder – 6 ft.