background image

 

 

Page | 11 

 

Starting the Engine 

1.  Ensure that the engine has a sufficient amount of fuel in the gas tank. (

Figure 3, 

Item 1

2.  Ensure that the fuel shut-off valve is open. (

Figure 3, Item 4

3.  Turn the Engine switch to the on position. (

Figure 3, Item 6

4.  If the Honda engine is cold, apply the choke. (

Figure 3, Item 3

5.  Pull the hand starter cord until the engine starts. (

Figure 3, Item 7

6.  Apply throttle (

Figure 3, Item 2

) and decrease the choke until it is no longer 

needed. The output of the pump is regulated by how much throttle is applied (as 

well as the shut-off at the nozzle, and the pump to tank return). 

DRAFT PROCEDURES 

Drafting From an Auxiliary Water Source 

Your QTAC has the ability to draft water from an auxiliary water source. The operator 

can either draft in order to fill the tank, or draft straight into the pump and out a discharge 

line, bypassing the tank. 

Connecting the Draft Hose 

Remove the Camlock cap covering the draft hose port. Secure the draft hose Camlock 

coupling to the draft hose port. (

Figure 2, Item 7

Drafting to Fill the Water Tank 

 

1.  Close the tank to pump valve. 

(

Figure 2, Item 6

Ensure that the pump head is 

primed. (

see Page 9

Содержание 85 EMS

Страница 1: ...Page 1 85 EMS Owner s Manual QTAC is a division of MTECH Inc 1072 Marauder Suite 210 Chico CA 95973 1 888 797 5100 www qtacfire com ...

Страница 2: ... Tank Water Supply 10 Starting the Engine 11 DRAFT PROCEDURES 11 Drafting From an Auxiliary Water Source 11 Connecting the Draft Hose 11 Drafting to Fill the Water Tank 11 Pumping While Drafting From an Auxiliary Water Source 12 To Supply Water to the 1 NPSH Discharge 13 STOPPING YOUR QTAC 13 GETTING TO KNOW YOUR ATP FOAM KIT 14 OPERATING YOUR ATP FOAM KIT 15 Before Using Your ATP Foam Kit 15 Usin...

Страница 3: ...OTING YOUR QTAC 18 The Pump Engine Will Not Start 18 The Pump Will Not Build Water Pressure 18 Water Will Not Discharge From The Discharge Hose 19 The Pump Engine Runs Erratically 19 TECHNICAL SPECIFICATIONS 20 ADDITIONAL REFERENCES 20 WARRANTY 21 ...

Страница 4: ...nk Components 1 Foam Cell Optional 5 Water Tank Site Gauge 2 Discharge Hose Reel 6 Water Tank Mounting Flange 3 Water Fill Tower 7 Water Tank Drain Port 4 Grab Handle 8 Litter Platform 3 6 5 4 3 2 7 7 4 5 6 1 1 8 8 2 MEDIUM PRESSURE HIGH PRESSURE ...

Страница 5: ... Open Position 1 Pressure Gauge HP units only 5 1 Pump to Reel Valve 2 Pump Primer Port 6 Tank to Pump Valve 3 1 NPSH Aux Discharge Valve 7 Draft Hose Port 4 1 Pump to Tank Valve 8 Pump Drain Port 6 8 2 3 7 1 2 3 4 4 5 MEDIUM PRESSURE 6 8 5 7 HIGH PRESSURE ...

Страница 6: ... 6 Figure 3 Pump Engine Components 1 Fuel Fill 5 Oil Fill 2 Engine Throttle 6 Engine Switch 3 Carburetor Choke 7 Pull Starter 4 Fuel Shut off Valve 2 3 4 1 5 6 7 1 2 3 4 5 6 7 MEDIUM PRESSURE HIGH PRESSURE ...

Страница 7: ...stening Figure 4 Mounting Options Ensure that your QTAC unit is secured to the carrying vehicle Two main mounting methods are available for your QTAC unit 1 The preferred method of securing the QTAC to the bed of the vehicle is to mount the QTAC at the flanges Figure 4 Item3 located at the bottom of the water tank on each side The flanges have been machined to accept a variety of mounting hardware...

Страница 8: ...ding area for your ATV or UTV Ensure that the weight of your QTAC does not exceed the maximum recommended weight of the ATV or UTV loading area to which you are securing your QTAC Loading the bed of your ATV or UTV may affect steering response Therefore the operator should spend some time operating the vehicle in a safe area e g wide and flat once the QTAC has been properly secured and loaded to e...

Страница 9: ...ls Figure 3 Item 5 as needed fill the pump engine with fuel and oil as specified in the engine manual that came with your QTAC For more information see the Pump Operation Manual and the Honda Owner s Manual PUMP OPERATION Priming the Pump after an Extended Period of Use The QTAC pumps are a self priming pump meaning they do not need to be primed before every use However if the pump is being starte...

Страница 10: ...SH Discharge should be fully closed Figure 2 Item 3 2 Start the engine see next page 3 Water can now be discharged through the reel line To operate the 1 NPSH discharge see page 13 CAUTION During pumping operations the operator MUST either a leave the pump to tank valve open slightly to bypass water through the pump reference Figure 2 Item 4 or b leave the nozzle at least partially open at all tim...

Страница 11: ... of the pump is regulated by how much throttle is applied as well as the shut off at the nozzle and the pump to tank return DRAFT PROCEDURES Drafting From an Auxiliary Water Source Your QTAC has the ability to draft water from an auxiliary water source The operator can either draft in order to fill the tank or draft straight into the pump and out a discharge line bypassing the tank Connecting the ...

Страница 12: ... pump head 6 Monitor the water level using the water level sight tube Figure 1 Item 5 7 Once the tank is full decrease the throttle setting and shut off the engine Return the valves to the positions needed in order to pull water from the tank and continue pumping operations see Page 10 Pumping While Drafting From an Auxiliary Water Source 1 Close the tank to pump valve Figure 2 Item 6 Ensure that ...

Страница 13: ...head 6 Use the hose reel discharge nozzle or 1 NPSH discharge line to carry out suppression operations To Supply Water to the 1 NPSH Discharge 1 Connect your hose fitting to the 1 NPSH discharge outlet 2 Lay out the hose open the discharge valve slowly Figure 2 Item 3 to charge the line and supply water to the nozzle STOPPING YOUR QTAC 1 If opened gradually close the shut off valve at the end of t...

Страница 14: ...UR ATP FOAM KIT Figure 5 Typical ATP Foam Plumbing 1 Foam Cell Tank 4 Supply Hose Strainer 2 Vented Lid 5 Foam Proportioner 3 Foam Supply Valve 6 Proportioner Pressure Valve 2 5 4 MEDIUM PRESSURE 6 1 2 3 5 6 4 1 3 HIGH PRESSURE ...

Страница 15: ...allow a slight flow 6 Close the 1 Pump to Tank Valve to stop the introduction of foam concentrate into the water tank Figure 2 Item 4 Remember that if this valve is closed a discharge must be open to prevent pump head overheating 7 Open the Foam Supply valve Figure 5 Item 3 and the Proportioner Pressure Valve Figure 5 Item 6 8 Open the discharge apply foam as desired NOTE It may take several secon...

Страница 16: ...ction Manual for additional details NOTE If your QTAC will be subjected to below freezing temperatures ensure that all water is drained from the water tank pumping system and hoses Store with all valves in the open position If you would like to keep water in your QTAC in below freezing temperatures make sure to add an appropriate amount of RV antifreeze to the water to prevent the formation of ice...

Страница 17: ...ntil all foam has been displaced SERVICING YOUR QTAC Cleaning Your QTAC Your QTAC water tank is best cleaned with plain water If additional cleaning power is needed a small amount of dish or car washing soap may be used Avoid heavy washing of the pump engine and surrounding area Avoid the use of high pressure spray on the water tank as the decals and rubber components may be damaged Protecting You...

Страница 18: ...e pump engine is running and operating at a sufficient speed Ensure that there is sufficient water in the water tank There should be enough water in the water tank so that the water level is visible in the water tank site gauge Figure 1 Item 5 Unless the draft hose kit is in use ensure that the Tank to Pump valve is open Figure 2 Item 6 so that the pump is drawing water from the water tank and not...

Страница 19: ...t off valve is open Ensure that the discharge hose nozzle is open The Pump Engine Runs Erratically Ensure that the engine has adequate fuel Low fuel levels and operation over rough and or sloping terrain can cause the engine to momentarily run out of fuel If the fuel has been stored for any length of time and it has not been stabilized drain the fuel system and fill with fresh fuel Proper engine p...

Страница 20: ...nt of your QTAC WATERAX VERSAX 6 Instruction Manual High Pressure Koshin SEH 40H Instruction Manual Medium Pressure Honda Owner s Manual We recommend that you read these manuals along with this QTAC Owner s Manual the WATERAX VERSAX 6 or Koshin SEH 40H and Honda manuals provide additional detail for the pump and pump engine respectively Tank Body Fully welded top grade Copolymer Polypropylene MTEC...

Страница 21: ...ered under the warranties below WHAT IS WARRANTED All parts of any Product are warranted for a period of 12 months with the warranty term beginning on the date Product is delivered to Purchaser Note that some components may carry a manufacturer s warranty see the appropriate component documentation for details Warranty statements required by law covering engine emission related parts and component...

Страница 22: ...mance or freedom from defect of Product covered by this warranty IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT APPLICABLE SHALL BE LIMITED IN DURATION TO THE APPLICABLE PERIOD OF WARRANTY SET FORTH IN THIS SECTION PURCHASER S ONLY REMEDIES IN CONNECTION WITH THE BREACH OR PERFORMANCE OF ANY WARRANTY ON THE PRODUCT ARE THOSE SET FORTH ON THIS PAGE IN NO EV...