14

Connections

AC Power Cord

Insert the molded receptacle of the AC power cord into the 
AC power inlet on the back of the RAVE 522aa. Plug the AC 
line connector into the AC outlet. The power supply will 
accept from 100 to 240 Volts AC, 47 to 440 Hertz, without 
any changes. If a different type of IEC power cord is 
required than the one supplied with your 522aa, contact 
QSC’s Technical Services Department.

CobraNet

Connect one end of a category-5 cable terminated with a 
RJ45 plug into the 

CobraNet

 receptacle. Insert the RJ45 

plug into the receptacle with the lock-tab oriented toward 
the bottom of the RAVE 522aa and push firmly until the 
connector locks into place (usually an audible “click” can 
be heard). Connect the other end to the appropriate Cobra-
Net network port.

QSControl

Connect one end of a category-5 cable terminated with an 
RJ45 plug into the 

QSControl

 receptacle. Insert the RJ45 

plug into the receptacle with the lock-tab oriented toward 
the bottom of the RAVE 522aa and push firmly until the 
connector locks into place (usually an audible “click” can 
be heard). Connect the other end to the appropriate QSCon-
trol.net network port.

Analog Audio Inputs and Outputs

Eight balanced audio inputs and outputs are provided, 

CH 1 

INPUT

 - 

CH 8 INPUT

 and 

CH 1 - CH 8 OUTPUT

. Plug the 

input signal terminal block connectors into the input recep-
tacles. Connection pin-out is printed on the rear label for 
reference. Refer to the illustrations for balanced and unbal-
anced connections. Use balanced audio connections when-
ever possible.

Omni In

The

 

six

 Omni In

 

connectors are two-pin terminal block con-

nectors. They can accept contact closure devices (switch, 
relay contacts) or 10k ohm variable resistors. The contact 
closure and logic devices accommodate on/off or state-
change events; the variable resistor input provides full 8-bit 
resolution allowing for incremental-change events. Refer to 
the illustrations for connection recommendations. NOTE! 
+48 volts is the absolute maximum that can be applied to 
the + pin without damage. Voltage is with respect to chas-
sis or the - pin.

Logic Out

The

 

four 

Logic Out

 

connectors are two-pin terminal block 

connectors. They provide CMOS logic level compatible sig-
nals for external devices.

Analog audio input- bal-
anced connection.

Logic Out connections. 
Negative (-) terminal is at 
chassis potential. Positive 
(+) terminal logic level is 
switched using software.

CobraNet and QSControl 
connection. Accepts rug-
gedized or normal shell-
less RJ45 plugs.

Omni In connections. Vari-
able input must be 10k ohm 
variable resistor. Contact 
closure input can be a 
switch or relay contacts. 
These inputs can operate 
software “devices”. Nega-
tive (-) terminal is at chas-
sis potential.

Analog audio input- unbal-
anced connection. Note 
jumper wire between - and 
ground.

Содержание RAVE 522aa

Страница 1: ...TD 000164 00 rev B TD 000164 00 RAVE 522aa 8x8 CobraNet Enabled Signal Processor Hardware Manual...

Страница 2: ...ord 5 Reliable Earthing Grounding of rack mounted equipment should be maintained LITHIUM BATTERY WARNING THIS EQUIPMENT CONTAINS A NON RECHARGEABLE LITHIUM BATTERY LITHIUM IS A CHEMICAL KNOWN TO THE S...

Страница 3: ...blets etc all at the same time from anywhere a connection to the QSControl network is available The QSControl network can also be managed from a single computer running both the client and the server...

Страница 4: ...ere We ve applied our many years experience in supporting high end installed sound with our previous system building products such as RAVE QSControl CM16a DSP 3 DSP 4 and DSP 30 The RAVE 522aa brings...

Страница 5: ...rules To learn more about CobraNet and appropriate network topologies please visit http www qscaudio com products network resources htm and http www peakaudio com CobraNet background html Notes on Ne...

Страница 6: ...a TCP IP standards compliant network system and therefore supports operation on network repeaters switches and routers When implementing the Two Wire Interface the QSControl net segment does not requ...

Страница 7: ...without a network switch However you would have to physically connect your computer first to one unit and then to the other With this elementary connection you don t have a true network It is like mak...

Страница 8: ...guration works well when CobraNet audio deliveries are point to point Though the example shows only two RAVE BASIS units as many devices may be connected as there are available switch ports All units...

Страница 9: ...te VLAN for QSControl net traffic and a separate VLAN for CobraNet audio traffic This config uration essentially provides a dedicated network for QSControl including the system controller and a second...

Страница 10: ...ith its own network switch Therefore traffic segmentation is physical rather than logical Example 5 also pro vides an additional level of fault tolerance although at the expense of additional network...

Страница 11: ...pment rack Rack mounting is optional Adhesive rubber feet are included for non rack mount installations Use them to prevent the unit from scratching or marring support surfaces Rack Mounting Rack moun...

Страница 12: ...m is used for real time adjustments and configuration of audio systems we recommend all Windows Power Options located in the Windows Control Panel features be disabled Display hard drive system standb...

Страница 13: ...ontroller computer CobraNet Connection Loss If you are operating with a valid CobraNet network and the connection to the network is disrupted audio will momentarily mute allow ing the RAVE 522aa to sy...

Страница 14: ...he input signal terminal block connectors into the input recep tacles Connection pin out is printed on the rear label for reference Refer to the illustrations for balanced and unbal anced connections...

Страница 15: ...stop bit and flow control Xon Xoff LED Indicators When the RAVE 522aa is plugged into a properly functioning AC outlet it will power up and briefly display a welcome screen on the LCD dis play POWER...

Страница 16: ...the control and accepting choices entering by pushing in on the control The accessible menus and sub menus may appear differently than the example shown Software updates may occasionally improve the i...

Страница 17: ...lt Boot Screen Right side buttons serve as up down navigation Arrow characters indi cate right side button context If additional menus are available the arrow character will be shown Main Menu Screens...

Страница 18: ...lient Server selection keep both Client and Server selected This will be appropriate for general use 8 When prompted Select Installation Folder specify the installation directory or accept the default...

Страница 19: ...nnections verify IP addresses are set correctly ver ify Subnet masks are set correctly and verify AC power is properly applied to the RAVE 19 Click on the RAVE 522aa in the inventory root A view of ap...

Страница 20: ...sed will be copies of other channels CobraNet Channel Resolution All CobraNet audio will be processed internally within RAVE 522aa at 24 bit resolution The RAVE 522aa may receive any valid resolu tion...

Страница 21: ...icate with the RAVE 522aa if it is in safe mode You may communicate only using TFTP Telnet or RS 232 RS 232 Serial Port I O Interface The RS 232 connector on the rear panel is used as a serial port in...

Страница 22: ...click OK to continue If all the connections and communications settings are correct the main Hyper Terminal window will open 6 The Hyper Terminal main window will appear next but blank Type the lette...

Страница 23: ...opening a Telnet session 1 To open the Telnet session Click START select RUN type Telnet followed by a space then the IP address of the RAVE 522aa you want to communicate with in the text box and cli...

Страница 24: ...lay Standard CobraNet Latency Low Latency RAVE to Network Analog input through full DSP chain to CobraNet output 7 104 milliseconds 4 438 milliseconds Network to RAVE CobraNet input through full DSP c...

Страница 25: ...a Euro Style detachable terminal blocks Configuration Single ended ground referenced Pinout 1 Signal 2 CHASSIS GND Normal Operating Range Reads signals between 0 5V nominally Potentiometer Operation...

Страница 26: ...ts suppliers be held liable for any damages consequential incidental or otherwise including any claims for lost profits and or savings resulting from any attempted integration of QSControl products wi...

Отзывы: