background image

2

IMPORTANT SAFETY PRECAUTIONS & EXPLANATION OF SYMBOLS

The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to 
the presence of uninsulated “dangerous” voltage within the product’s enclosure that may be of sufficient 
magnitude to constitute a risk of electric shock to humans.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of 
important operating and maintenance (servicing) instructions in this manual.

SAFEGAURDS
Electrical energy can perform many useful functions. This unit has been engineered and manufactured to 
assure your personal safety. Improper use can result in potential electrical shock or fire hazards. In order 
not to defeat the safeguards, observe the following instructions for its installation, use and servicing.

CAUTION: To reduce the risk of electric shock, do not remove the cover. No user-serviceable parts inside. 
Refer servicing to qualified service personnel.

WARNING: To prevent fire or electric shock, do not expose this equipment to rain or moisture.

1- Maximum operating ambient temperature is 50°C (122°F).
2- Never restrict airflow through the device fan or vents. Please insure that the air intake and exhaust 
vents are unobstructed.
3- When installing equipment into rack, distribute the units evenly. Otherwise, hazardous conditions 
could be created by an uneven weight distribution.
4- Connect the unit only to a properly rated supply circuit. The RAVE 522aa is suitable for connection to 
100 - 240 VAC, 47 - 440 hertz, with no special considerations other than the appropriate IEC power cord.
5- Reliable Earthing (Grounding) of rack-mounted equipment should be maintained.

LITHIUM BATTERY WARNING
THIS EQUIPMENT CONTAINS A NON-RECHARGEABLE LITHIUM BATTERY. LITHIUM IS A CHEMICAL 
KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER OR BIRTH DEFECTS. THE NON-RECHARGE-
ABLE LITHIUM BATTERY CONTAINED IN THIS EQUIPMENT MAY EXPLODE IF IT IS EXPOSED TO FIRE OR 
EXTREME HEAT. DO NOT SHORT CIRCUIT THE BATTERY. DO NOT ATTEMPT TO RECHARGE THE NON-
RECHARGEABLE LITHIUM BATTERY.

FCC INTERFERENCE STATEMENT
NOTE: This equipment has been tested and found to comply with the limits for a class B digital device, 
pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against 
harmful interference in a residential installation. This equipment generates, uses, and can radiate radio 
frequency energy and if not installed and used in accordance to the instructions, may cause harmful 
interference to radio communications. However, there is no guarantee that interference will not occur in 
a particular installation. If this equipment does cause harmful interference to radio or television recep-
tion, which can be determined by switching the equipment off and on, the user is encouraged to try to 
correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio or TV technician for help.

© Copyright 2004 QSC Audio Products, Inc. QSC® is a registered trademark of QSC Audio Products, Inc. “QSC” and the QSC logo are registered 

with the U.S. Patent and Trademark Office. All trademarks are the property of their respective owners.

Содержание RAVE 522aa

Страница 1: ...TD 000164 00 rev B TD 000164 00 RAVE 522aa 8x8 CobraNet Enabled Signal Processor Hardware Manual...

Страница 2: ...ord 5 Reliable Earthing Grounding of rack mounted equipment should be maintained LITHIUM BATTERY WARNING THIS EQUIPMENT CONTAINS A NON RECHARGEABLE LITHIUM BATTERY LITHIUM IS A CHEMICAL KNOWN TO THE S...

Страница 3: ...blets etc all at the same time from anywhere a connection to the QSControl network is available The QSControl network can also be managed from a single computer running both the client and the server...

Страница 4: ...ere We ve applied our many years experience in supporting high end installed sound with our previous system building products such as RAVE QSControl CM16a DSP 3 DSP 4 and DSP 30 The RAVE 522aa brings...

Страница 5: ...rules To learn more about CobraNet and appropriate network topologies please visit http www qscaudio com products network resources htm and http www peakaudio com CobraNet background html Notes on Ne...

Страница 6: ...a TCP IP standards compliant network system and therefore supports operation on network repeaters switches and routers When implementing the Two Wire Interface the QSControl net segment does not requ...

Страница 7: ...without a network switch However you would have to physically connect your computer first to one unit and then to the other With this elementary connection you don t have a true network It is like mak...

Страница 8: ...guration works well when CobraNet audio deliveries are point to point Though the example shows only two RAVE BASIS units as many devices may be connected as there are available switch ports All units...

Страница 9: ...te VLAN for QSControl net traffic and a separate VLAN for CobraNet audio traffic This config uration essentially provides a dedicated network for QSControl including the system controller and a second...

Страница 10: ...ith its own network switch Therefore traffic segmentation is physical rather than logical Example 5 also pro vides an additional level of fault tolerance although at the expense of additional network...

Страница 11: ...pment rack Rack mounting is optional Adhesive rubber feet are included for non rack mount installations Use them to prevent the unit from scratching or marring support surfaces Rack Mounting Rack moun...

Страница 12: ...m is used for real time adjustments and configuration of audio systems we recommend all Windows Power Options located in the Windows Control Panel features be disabled Display hard drive system standb...

Страница 13: ...ontroller computer CobraNet Connection Loss If you are operating with a valid CobraNet network and the connection to the network is disrupted audio will momentarily mute allow ing the RAVE 522aa to sy...

Страница 14: ...he input signal terminal block connectors into the input recep tacles Connection pin out is printed on the rear label for reference Refer to the illustrations for balanced and unbal anced connections...

Страница 15: ...stop bit and flow control Xon Xoff LED Indicators When the RAVE 522aa is plugged into a properly functioning AC outlet it will power up and briefly display a welcome screen on the LCD dis play POWER...

Страница 16: ...the control and accepting choices entering by pushing in on the control The accessible menus and sub menus may appear differently than the example shown Software updates may occasionally improve the i...

Страница 17: ...lt Boot Screen Right side buttons serve as up down navigation Arrow characters indi cate right side button context If additional menus are available the arrow character will be shown Main Menu Screens...

Страница 18: ...lient Server selection keep both Client and Server selected This will be appropriate for general use 8 When prompted Select Installation Folder specify the installation directory or accept the default...

Страница 19: ...nnections verify IP addresses are set correctly ver ify Subnet masks are set correctly and verify AC power is properly applied to the RAVE 19 Click on the RAVE 522aa in the inventory root A view of ap...

Страница 20: ...sed will be copies of other channels CobraNet Channel Resolution All CobraNet audio will be processed internally within RAVE 522aa at 24 bit resolution The RAVE 522aa may receive any valid resolu tion...

Страница 21: ...icate with the RAVE 522aa if it is in safe mode You may communicate only using TFTP Telnet or RS 232 RS 232 Serial Port I O Interface The RS 232 connector on the rear panel is used as a serial port in...

Страница 22: ...click OK to continue If all the connections and communications settings are correct the main Hyper Terminal window will open 6 The Hyper Terminal main window will appear next but blank Type the lette...

Страница 23: ...opening a Telnet session 1 To open the Telnet session Click START select RUN type Telnet followed by a space then the IP address of the RAVE 522aa you want to communicate with in the text box and cli...

Страница 24: ...lay Standard CobraNet Latency Low Latency RAVE to Network Analog input through full DSP chain to CobraNet output 7 104 milliseconds 4 438 milliseconds Network to RAVE CobraNet input through full DSP c...

Страница 25: ...a Euro Style detachable terminal blocks Configuration Single ended ground referenced Pinout 1 Signal 2 CHASSIS GND Normal Operating Range Reads signals between 0 5V nominally Potentiometer Operation...

Страница 26: ...ts suppliers be held liable for any damages consequential incidental or otherwise including any claims for lost profits and or savings resulting from any attempted integration of QSControl products wi...

Отзывы: