EXPLANATION OF TERMS AND SYMBOLS

The term “

WARNING!

” indicates instructions regarding personal safety. If the instructions are not followed the result may be bodily injury or death.

The term “

CAUTION!

” indicates instructions regarding possible damage to physical equipment. If these instructions are not followed, it may result in 

damage to the equipment that may not be covered under the warranty.

The term “

IMPORTANT!

” indicates instructions or information that are vital to the successful completion of the procedure.

The term "

NOTE

" is used to indicate additional useful information.

The intent of the lightning flash with arrowhead symbol in a triangle is to alert the user to the presence of un-insulated "dangerous" 
voltage within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to humans. 

The intent of the exclamation point within an equilateral triangle is to alert the user to the presence of important safety, and operating 
and maintenance instructions in this manual.

IMPORTANT SAFETY INSTRUCTIONS

 ARNINNG!:

 

TO PREVENT FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.  

– Maximum operating ambient temperature is 50°C (122°F) for the I/O Frame, 45°C (113°F) for the Core. 
– Power requirements are: 100 – 240 VAC, 50 – 60 Hz, and the proper IEC power cord. 
– Ensure reliable earth grounding is maintained. 
– Distribute the units evenly when installing in a rack. Hazardous conditions can be created by uneven weight distribution.

•  Read these instructions.
•  Keep these instructions.
•  Heed all warnings.
•  Follow all instructions.
•  Do not use this apparatus near water.
•  Clean only with a dry cloth.
•  Do not block any ventilation opening. Install in accordance with the manufacturer's instructions.
•  Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
•  Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A 

grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided 
plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

•  Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from 

the apparatus.

•  Only use attachments/accessories specified by the manufacturer.
•  Unplug this apparatus during lightning storms or when unused for long periods of time.
•  Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply 

cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, 
does not operate normally, or has been dropped.

•  The AC Mains plug is the AC mains disconnect device and shall remain readily accessible after installation. 
•  Adhere to all applicable, local codes.
•  Consult a licensed, professional engineer when any doubt or questions arise regarding a physical equipment installation.

LITHIUM BATTERY  ARNINN

THIS EQUIPMENT MAY CONTAIN A NON-RECHARGEBLABE LITHIUM BATTERY. LITHIUM IS A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA 
TO CAUSE CANCER OR BIRTH DEFECTS. THE NON-RECHARGEABLE LITHIUM BATTERY CONTAINED IN THIS EQUIPMENT MAY EXPLODE IF IT 
IS EXPOSED TO FIRE OR EXTREME HEAT. DO NOT SHORT CIRCUIT THE BATTERY. DO NOT ATTEMPT TO RECHARGE THE NON-RECHARGEABLE 
LITHIUM BATTERY.

Содержание Q-SYS Core 1000

Страница 1: ...TD 000284 00 Core 1000 Centralized audio and control processor Core 3000 Centralized audio and control processor Core 4000 Centralized audio and control processor I O Frame Networked audio and contro...

Страница 2: ...ing Install in accordance with the manufacturer s instructions Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Do...

Страница 3: ...QSC has any authority to alter or modify in any manner the disclosures and recommendations set forth herein QSC Audio Products 3 Year Limited Warranty QSC Audio Products LLC QSC guarantees its produc...

Страница 4: ...arton Q Sys Core 1000 Core 3000 Core 4000 or Q Sys I O Frame product Rubber feet Hardware Manual Q Sys Designer software CD Core 1000 Core 3000 and Core 4000 products only IEC power cord and cord lock...

Страница 5: ...ds are ordered in the product configuration a shop kit containing the mating plugs is included in the carton contents Plug the Euro terminal block plug into the appropriate input or output receptacle...

Страница 6: ...pointing device PC Hardware Requirements for Windows XP Professional PC with 300 megahertz or higher processor clock speed recommended 233 MHz minimum required single or dual processor system Intel Pe...

Страница 7: ...name or the name of the I O Frame component in Q Sys Designer so they match A new I O Frame is shipped with both LANs enabled and the addressing Mode set to Auto Auto If there is a DHCP server on the...

Страница 8: ...ptional provides the interface between digital devices such as mixing consoles recording devices other devices and Q Sys Blank Card Optional fills card slot when no card is needed Q Sys Designer Softw...

Страница 9: ...lth and to synchronize control settings 2N Network redundancy Two separate networks In this configuration you can have each Q Sys Core and or I O Frame connected to both networks 2N I O redundancy For...

Страница 10: ...n Button 6 Device ID Button locates device in Q Sys Designer GUI 7 Status LED reports network health ID and firmware update status 8 Power On LED 9 Clear Settings Paperclip Button resets network prope...

Страница 11: ...are available for field installation by qualified service personnel Front Panel Rear Panel Figure 7 1 2 3 4 5 7 8 6 1 Fan Exhaust Vents 2 Audio I O Signal and Card Present Indicators 3 240 x 64 Monoc...

Страница 12: ...in positions A or B remove the four Phillips head screws securing the card to the standoffs Remove the card If you are not replacing a card in position C or D skip to step 7 b For cards in positions...

Страница 13: ...oE 3560E 24PD SG 300 10P SLM2024 3500yl 48G PWR 3560E 48PD SG 300 10MP SLM2048 3500yl 48G PoE 3560E 48TD SG 300 20 SRW Series Managed Switches EOL 5406zl all modules 3560E 48PD F SG 300 28 SRW2008 541...

Страница 14: ...ignal Five tri color LEDs 240 x 64 monochrome LCD graphics display Power On Blue LED Device Status Tri color LED Audio Signal Five tri color LEDs per I O card slot 240 x 64 monochrome LCD graphics dis...

Страница 15: ...110 dB 110 dB 110 dB 110 dB 110 dB 100 dB 110 dB 100 dB 110 dB 95 dB 100 dB 100 dB 110 dB Frequency Response 20 Hz 20 kHz max Frequency Response 20 Hz 20 kHz typ 0 5 dB 0 2 dB 0 5 dB 0 2 dB 0 5 dB 0 2...

Страница 16: ...d legacy V1 models 4 Group Delay assumes that the sample rate converter is enabled CobraNet I O Card CobraNet Input Output CCN32 Description Up to 32 input and 32 output channels of CobraNet digital a...

Страница 17: ...CA 92626 1468 USA Main Number 714 754 6175 Sales Marketing 714 957 7100 or toll free USA only 800 854 4079 Sales Marketing FAX 714 754 6174 Customer Service FAX 714 754 6173 qscaudio com info qscaudio...

Отзывы: