8
TD-001572-01-A
Connections
Wiring
• For all wiring
• Strip Length = 5mm See Figure 7.
• DO NOT TIN!
IMPORTANT!E:
Class 2 Wiring on all outputs.
— Figure 7 —
5mm
1:1
Outputs
IMPORTANT!E:
Class 2 Wiring on all outputs
• One for each channel
• 3.5 mm Euro, 4-pin (green)
MP-A20V (1x)
MP-A40V (2x)
MP-A80V (4x)
CAUTION!E:
Do not connect any output to ground.
The outputs are configured individually for the application intended for that particular
output. DIP switches are provided to perform the configuration. The amplifier uses
the DIP switch settings to set the power requirements. Make sure the switches match
the configuration.
The DIP switches are located up and to the right of the associated channel
attenuation knob. In addition there is a chart on the rear panel of the amplifier with the
setting information.
The output power settings use DIP switches labeled A and B.
100 V Setting – both DIP switches are in the down position.
Use this setting when you have multiple loudspeakers on one
channel. Make sure the loudspeaker's transformer is set to 100V.
70 V Setting – DIP switch A is up, B is down. Use this setting
when you have multiple loudspeakers on one channel. Make sure
the loudspeaker's transformer is set to 70V.
8 Ω Setting – DIP switch A is down, DIP switch B is up.
4 Ω Setting – both DIP switches are in the up position.
80 Hz High-pass Filter On – The HPF switch is in the up, or
on position. (proper setting for most 70 V and 100 V systems)
80 Hz High-pass Filter Off – The HPF switch is in the down, or
off position.