2

 TD-001572-01-A

EXPLANATION OF SYMBOLS

The term “

WARNING!

” indicates instructions regarding personal safety. If the instructions are not followed the result may be bodily injury or death.

The term “

CAUTION!

” indicates instructions regarding possible damage to physical equipment. If these instructions are not followed, it may 

result in damage to the equipment that may not be covered under the warranty.

The term “

IMPORTANT!

” indicates instructions or information that are vital to the successful completion of the procedure.

The term "

NOTE

" is used to indicate additional useful information.

NOTEE:

 

The intent of the lightning flash with arrowhead symbol in a triangle is to alert the user to the presence of un-insulated 

"dangerous" voltage within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to humans. 

NOTEE:

 

The intent of the exclamation point within an equilateral triangle is to alert the user to the presence of important safety, and 

operating and maintenance instructions in this manual.

IMPORTANT SAFETY INSTRUCTIONS

WARNING!E:

 

TO PREVENT FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN 

OR MOISTURE.  
Elevated Operating Ambient – If installed in a closed or multi-unit rack assembly, the ambient operating 
temperature of the rack environment may be greater than room ambient. Consideration should be 
given to ensure that the maximum operating temperature range -10°C to 50°C (14°F to 122°F ) is not 
exceeded. Reduced Air Flow – Installation of the equipment in a rack should be such that the amount 
of air flow required for safe operation of the equipment is not compromised.

1.  Read these instructions.
2.  Keep these instructions.
3.  Heed all warnings.
4.  Follow all instructions.
5.  Do not use this apparatus near water.
6.  Do not submerge the apparatus in water or liquids. 
7.  Do not use any aerosol spray, cleaner, disinfectant or fumigant on, near or into the apparatus. 
8.  Clean only with a dry cloth.
9.  Do not block any ventilation opening. Install in accordance with the manufacturer's instructions.
10.  Keep all ventilation openings free of dust or other matter.
11.  Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
12.  To reduce the risk of electrical shock, the power cord shall be connected to a mains socket outlet with a protective earthing connection.
13.  Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A 

grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided 
plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

14.  Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from 

the apparatus.

15.  Do not unplug the unit by pulling on the cord, use the plug.
16.  Only use attachments/accessories specified by the manufacturer.
17.  Unplug this apparatus during lightning storms or when unused for long periods of time.
18.  Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as 

power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to 
rain or moisture, does not operate normally, or has been dropped.

19.  The appliance coupler, or the AC Mains plug, is the AC mains disconnect device and shall remain readily accessible after installation. 
20.  Adhere to all applicable, local codes.
21.  Consult a licensed, professional engineer when any doubt or questions arise regarding a physical equipment installation.

Содержание MP-A Series

Страница 1: ...TD 001572 01 A TD 001572 01 MP A Series User Manual MP A20V MP A40V MP A80V...

Страница 2: ...apparatus in water or liquids 7 Do not use any aerosol spray cleaner disinfectant or fumigant on near or into the apparatus 8 Clean only with a dry cloth 9 Do not block any ventilation opening Instal...

Страница 3: ...his equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by...

Страница 4: ...roper operating temperatures utilizing convection cooling via the aluminum chassis for typical background music loads The variable speed cooling fan s are thermally regulated and operate only during s...

Страница 5: ...gy achieves this by allowing the installer to configure each pair of channels e g ch 1 2 or 3 4 etc to deliver up to 400 W combined output power in any mix This makes for an amazing amount of flexibil...

Страница 6: ...dd these tap settings to get the maximum amount of power used on this output channel 25 W 25 W 50 W In step 3 above there were 150 W available subtract 50 W this channel s total from the available 150...

Страница 7: ...hannel Configurable with DIP switches Negative Positive pins 5 0 mm Euro 4 pin one for every 2 outputs green Class 2 Wiring 6 Remote Provides remote control of the standby mode of the amplifier Provid...

Страница 8: ...of the associated channel attenuation knob In addition there is a chart on the rear panel of the amplifier with the setting information The output power settings use DIP switches labeled A and B 100...

Страница 9: ...ire three wires ground negative and positive Unbalanced requires a jumper between the ground pin and the negative pin Input Levels Input sensitivity 1 23 V 4 dBu Is the input level you must supply wit...

Страница 10: ...has no effect on the amplifier status When the switch is closed the amplifier goes into standby Relay The REMOTE RELAY provides a means to monitor the amplifier s operating condition with external equ...

Страница 11: ...6 mm 1 72 in 358 7 mm 14 12 in 12 7 mm 0 5 in 15 5 mm 0 6 in 31 8 mm 1 25 in 5 9 mm 0 23 in 21 8 mm 0 86 in 23 9 mm 0 94 in 21 8 mm 0 86 in 18 3 mm 0 72 in 377 0 mm 14 84 in 481 3 mm 18 95 in 12 7 mm...

Страница 12: ...mited to observe the maximum power rating 30 W Cooling Type Forced air cooling thermally regulated fan speed side rear to front airflow Operating temperature range Maximum 10 50 C recommended 0 35 C p...

Страница 13: ...13 TD 001572 01 A Notes...

Страница 14: ...of their respective owners http patents qsc com Contact QSC QSC LLC 1675 MacArthur Boulevard Costa Mesa CA 92626 1468 USA Main Number 1 714 754 6175 Toll Free 800 854 4079 US Only Website www qsc com...