Introduction

The DXP adds new capabilities to the DCP line of Digital Cinema Processors, creating a powerful solution for today’s networked D-Cinema audio 
systems. From server to speakers, the DCP and DXP combine to offer a complete set of tools to facilitate all the signal processing, audio distribution, 
monitoring and automation control services required in a modern D-Cinema sound system.

A single DXP provides all signal processing and monitoring functions for up to 12 DCA Amplifi ers connected via DataPort connectors. The DXP also 
offers relays and contact closure inputs to interface with automations and other theatre systems like masking, dimmers, and curtain, as well as a Mic/
Line input to facilitate connection of podium microphones in multi-use facilities.

The DCP and DXP communicate via CobraNet on a standard Ethernet infrastructure. Up to two DXP's may be connected to each DCP. The DXP 
requires a DCP for operation.

The DXP provides advanced DSP presets for QSC’s Digital Cinema Speakers (DCS), the DXP optimizes loudspeaker performance while simplifying 
cinema sound system wiring and confi guration. The DXP can provide crossovers for bi-amp, tri-amp or quad-amp operation or it can be used to power 
full range systems like surround channels.

The use of standard Ethernet infrastructure allows the power amplifi ers for the screen channels and subwoofers to be mounted near the speakers, 
eliminating long and expensive speaker cables and conduit. The DataPort connection through the DXP allows the remote-mounted amps and speakers 
to be fully monitored and controlled from the DCP.

The DCP/DXP combination is more than an audio processor. Whether designing a system for a single auditorium or designing a large multiplex, the 
DCP and DXP together offer the fl exibility in confi guration, networking, audio distribution and advanced management services to get the job done.

Features

•  The DXP accepts 16 Digital inputs via CobraNet. It supports crossover processing for up to 5 screen channels or up to 6 Auxiliary (point 

source) channels.

•  Analog Mic/Line Input

•  Compatible with all existing QSC DCA amplifi ers

•  Dual internal power supplies seamless recovery in the event of a failure

•  Continued development of software and fi rmware will add new capabilities via easy updates

Digital Signal Processing

The DXP digital signal processing capability outperforms traditional analog crossovers and equalizers for optimized speaker performance. Crossover 
frequency, parametric equalization, polarity, delay and gain can be precisely adjusted for each speaker in your system. Active 2-way, 3-way and 4-way 
crossovers are available. Advanced crossover presets for QSC DCS speakers speeds system set-up and ensures maximum performance. Full range 
outputs for surround channels are also supported.

Less Wiring, Faster Setup

The DXP greatly simplifi es system wiring and setup, signifi cantly reducing installation time and labor cost. Input to the DXP is provided via standard 
Ethernet hardware via CobraNet from the associated DCP. Digital audio is routed over the network from the DCP to the DXP. The use of QSC's HD-15 
DataPort cables to connect the DCA amplifi ers to the DXP speeds installation as all traditional XLR and barrier strip terminations are eliminated. 

DCP and DXP processors simplify setup by using a menu-driven, PC-based software program for confi guration. The program includes a speaker data 
fi le that lists default parameters for popular cinema speaker models. Commonly used confi gurations can also be saved on a disk, or redistributed 
across a network, allowing easy transfer of settings to the DXP. All confi guration data may be saved to an SD memory card in the DCP, allowing easy 
transfer of settings to a new (backup) DCP or DXP, should replacement ever be required.

Advanced Monitor and Control Functions

In addition to audio monitoring of amplifi er inputs and outputs, the DXP includes QSC’s exclusive “load fault” detection. The DXP monitors all 
amplifi er outputs and indicates opens and shorts in the speaker system, providing confi rmation that all amplifi er outputs are functioning properly. In 
addition, the DXP detects all amplifi er clipping and protect modes, and heat sink temperature. The DXP can also turn amps off and on, and control 
external devices via the four relay outputs.

DCP Connect applications for iOS and Android mobile devices provide system control, fault reporting, and diagnosis, accessible through remote wi-fi  
network access throughout a cinema multiplex.

Содержание DXP Series

Страница 1: ...DXP Series Digital Cinema Hardware User Manual DXP Digital Expansion Processor TD 000371 00 A TD 000371 00...

Страница 2: ...ructed 3 When installing equipment into a rack distribute the units evenly Otherwise hazardous conditions could be created by an uneven distribution of weight 4 Connect the unit only to a properly rat...

Страница 3: ...ftware or data contained on the serviced unit not originally included in the product Customers may have additional rights which vary from state to state or from country to country In the event that a...

Страница 4: ...er supplies seamless recovery in the event of a failure Continued development of software and firmware will add new capabilities via easy updates Digital Signal Processing The DXP digital signal proce...

Страница 5: ...rol connection b Green audio and control connections are both good c Amber either the audio or control connection is not working DXP Rear Panel Features 1 Analog audio input Mic Line 2 DataPort interf...

Страница 6: ...ET to save and restart the DXP or Press Page to move cursor to N Press Set to exit edit mode without saving Press PAGE to move to next page 3 N A SN xxxxxxxxxx Serial Number FW 0 00 0000 Firmware Vers...

Страница 7: ...nsure that these rear mounting points are securely fastened to rear rack rails or rack side walls Configuring the DXP DCP Manager is used to configure the DCP DXP system This includes configuring the...

Страница 8: ...is connected to the NO contact and the NC contact is not connected DataPorts QSC DataPorts on the DXP rear panel are intended to interface to QSC amplifiers with v1 DataPorts These are the all capabl...

Страница 9: ...ic phantom power or line level Available sensitivity settings 16 dBu 10 dBu 21 dBu 27 dBu Band polarity Normal inverted DataPort outputs HD 15 x12 QSC amplifier interface Band delay Programmable in 21...

Страница 10: ...ce FAX 714 754 6173 World Wide Web www qsccinema com E mail info qscaudio com service qscaudio com 2012 QSC Audio Products LLC All rights reserved QSC the QSC logo QSControl net QSControl DCP Manager...

Отзывы: