EXPLANATION OF SYMBOLS

The term “

WARNING!

” indicates instructions regarding personal safety. If the instructions are not followed the result may be bodily injury or death.

The term “

CAUTION!

” indicates instructions regarding possible damage to physical equipment. If these instructions are not followed, it may result in 

damage to the equipment that may not be covered under the warranty.

The term “

IMPORTANT!

” indicates instructions or information that are vital to the successful completion of the procedure.

The term "

NOTE

" is used to indicate additional useful information.

The intent of the lightning fl ash with arrowhead symbol in a triangle is to alert the user to the presence of un-insulated "dangerous" 
voltage within the product's enclosure that may be of suffi cient magnitude to constitute a risk of electric shock to humans. 

The intent of the exclamation point within an equilateral triangle is to alert the user to the presence of important safety, and operating 
and maintenance instructions in this manual.

IMPORTANT SAFETY INSTRUCTIONS

WARNING!: 

 

TO PREVENT FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. 

1.  Maximum operating ambient temperature is 50°C (122°F).

2.  Never restrict airfl ow through the device vents. Please insure that the side panel vents are unobstructed.

3.  When installing equipment into a rack, distribute the units evenly. Otherwise, hazardous conditions could be created by an uneven 

distribution of weight.

4.  Connect the unit only to a properly rated supply circuit. The DXP is suitable for connection to 100-240VAC, 50-60Hz with no special 

considerations other than the appropriate IEC power cord.

5.  Reliable earthing (grounding) of rack-mounted equipment should be maintained.

FCC Statement

NOTE: 

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the 

FCC Rules. 

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses 
and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio 
communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful 
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct 
the interference by one or more of the following measures:

•  Reorient or relocate the receiving antenna.

•  Increase the separation between the equipment and receiver.

•  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

•  Consult the dealer or an experienced radio/TV technician for help.

Содержание DXP Series

Страница 1: ...DXP Series Digital Cinema Hardware User Manual DXP Digital Expansion Processor TD 000371 00 A TD 000371 00...

Страница 2: ...ructed 3 When installing equipment into a rack distribute the units evenly Otherwise hazardous conditions could be created by an uneven distribution of weight 4 Connect the unit only to a properly rat...

Страница 3: ...ftware or data contained on the serviced unit not originally included in the product Customers may have additional rights which vary from state to state or from country to country In the event that a...

Страница 4: ...er supplies seamless recovery in the event of a failure Continued development of software and firmware will add new capabilities via easy updates Digital Signal Processing The DXP digital signal proce...

Страница 5: ...rol connection b Green audio and control connections are both good c Amber either the audio or control connection is not working DXP Rear Panel Features 1 Analog audio input Mic Line 2 DataPort interf...

Страница 6: ...ET to save and restart the DXP or Press Page to move cursor to N Press Set to exit edit mode without saving Press PAGE to move to next page 3 N A SN xxxxxxxxxx Serial Number FW 0 00 0000 Firmware Vers...

Страница 7: ...nsure that these rear mounting points are securely fastened to rear rack rails or rack side walls Configuring the DXP DCP Manager is used to configure the DCP DXP system This includes configuring the...

Страница 8: ...is connected to the NO contact and the NC contact is not connected DataPorts QSC DataPorts on the DXP rear panel are intended to interface to QSC amplifiers with v1 DataPorts These are the all capabl...

Страница 9: ...ic phantom power or line level Available sensitivity settings 16 dBu 10 dBu 21 dBu 27 dBu Band polarity Normal inverted DataPort outputs HD 15 x12 QSC amplifier interface Band delay Programmable in 21...

Страница 10: ...ce FAX 714 754 6173 World Wide Web www qsccinema com E mail info qscaudio com service qscaudio com 2012 QSC Audio Products LLC All rights reserved QSC the QSC logo QSControl net QSControl DCP Manager...

Отзывы: