The RS-232 port is used only for setup and system troubleshooting. Connect the 9-pin serial data cable from
the host PC to this connector on the DCM. Orient the male DB9 connector to match up with the RS-232 port,
push the connector into the receptacle to seat it, and finger-tighten the retaining screws. Do not use “null-
modem”-type serial data cables; they will not work with the DCM. Use a “normal” 9-pin serial data cable.

The other end of the 9-pin serial data cable must be connected to an available RS-232 port on the host PC.
The PC must have QSC’s DCM Manager software installed on its hard drive. Start the DCM Manger pro-
gram and verify RS-232 communication between the PC and DCM. Refer to the DCM Manager software
help system for details.

RS-232 CONNECTION

Male end to DCM RS-232 Port

INSTALLATION- 

Connections: RS-232

9-pin Serial Data Cable-
use normal data cable.
Do not use null-modem
type cable.

Female end to host PC RS-232 Port

RS-232 Pinout-

Configuration: 

9-pin SubD male to 9-pin SubD female normal serial data cable.

Pin#

Signal Description

1

Loopback

2

Transmit

3

Receive

4

Loopback

5

Digital Ground

6

Loopback

7

Clear to Send

8

Request to Send

9

(not used)

Содержание DCM-1

Страница 1: ...1 DCM Series TD 000106 00 TD 000106 00 Rev B Digital Cinema Monitor Crossover System USER MANUAL DCM 1 DCM 2 DCM 3...

Страница 2: ...arts stands tripods brackets interconnecting cables or software specified by QSC Audio Products When moving or transporting using a cart use caution to avoid injury from tip over 13 Unplug the apparat...

Страница 3: ...reement DCM Manager is a trademark of QSC Audio Products Inc Windows and Windows 98 NT XP and 2000 are trademarks of Microsoft Corporation IBM is a registered trademark of IBM Corporation Pentium is a...

Страница 4: ...via a personal computer PC These modifications can be password protected for tamper proof system control Fast Setup with Easy Wiring Your DCM takes advantage of the unique DataPort found on DCA Series...

Страница 5: ...G 6 feet long 120V 5 warranty card 6 QSC store catalog 7 QSC accessories sheet 8 DCM Manager Application Disk SYSTEM REQUIREMENTS and UNPACKING DCM Manager software is designed to control one DCM hard...

Страница 6: ...ers The DataPort connections replace amplifier audio input cables and amplifier output monitor connections Another unique feature of the QSC Cinema System is the ability to automatically analyze volta...

Страница 7: ...for routing to the QSC amplifiers SYSTEM CONCEPTS 3 DSP processing Digital filtering of audio signals is known to have several advantages over analog solutions DSP digital signal processor IC chips al...

Страница 8: ...ostics fault indicator LEDs 8 Monitor output test points 9 Bypass switch DCM 1 FRONT PANEL 1 Emergency bypass level controls 2 Subwoofer output 3 Hearing Impaired system output 4 Audio input connector...

Страница 9: ...t indicator LEDs 8 Monitor output test points 9 Bypass switch DCM 2 FRONT PANEL 1 Emergency bypass level controls bypass switches 2 DataPort outputs to amplifiers 3 Audio input connector from Cinema P...

Страница 10: ...ault indicator LEDs 8 Monitor output test points 9 Bypass switch DCM 3 FRONT PANEL 1 Emergency bypass level controls bypass switches 2 DataPort outputs to amplifiers 3 Audio input connector from Cinem...

Страница 11: ...f the AMPS PROC switch The LEDs directly over the PROC AMPS switch indicate what selected function the Monitor Select buttons will have When the PROC LED is illuminated the Monitor Select buttons will...

Страница 12: ...SR1 signals to the speakers closest to the screen SL2 and SR2 in the next set of speakers further away from the screen and the SL3 and SR3 connections furthest back in the theater In Surround Decoder...

Страница 13: ...there is no amplifier detected at that DCM amplifier connector If the AMP LED is on the amplifier on at that output is measuring a short or an open on its output terminals REMEMBER If you configured...

Страница 14: ...osition the PROC center channel signal is routed to a passive crossover no power is required and then to the center channel amplifier There are level adjustments on the rear panel for balanc ing the h...

Страница 15: ...utputs with separate processing are included for additional theater configuration flexibility The rear panel labeling on the DCM has all of the information required by an audio installer When starting...

Страница 16: ...MODE switch DCM 2 and DCM 3 only internally routes the Center channel input signal through the 2 way passive crossover or the 3 way passive crossover The BI AMP ROUTING switch DCM 2 and DCM 3 only rou...

Страница 17: ...or the terminal strip connection but not both at the same time This connection cannot be monitored or include any of the Fault Analysis functions because there are no connec tions back from this exter...

Страница 18: ...rer for optimum sound performance Select speakers for each of the physical locations L C R SL SR SUB and a large portion of the system calibration is finished NOTE QSC updates these files regularly as...

Страница 19: ...ners on the bottom and press firmly to activate the pressure sensitive adhesive If rack mounting the DCM secure the DCM to the rack rails using four machine screws and washers of the proper size Most...

Страница 20: ...031 00 Method 2 The DCM is first installed from the front of the rack and secured to the front rack rails Temporarily secure the rear ears to the rear rack rails and select the appropriate mounting po...

Страница 21: ...d makes any required connection changes fast easy and reliable REQUIRED CABLES typical system AC MAINS CONNECTION Locate the IEC style AC power cord supplied with your DCM Identify the IEC end molded...

Страница 22: ...d to an available RS 232 port on the host PC The PC must have QSC s DCM Manager software installed on its hard drive Start the DCM Manger pro gram and verify RS 232 communication between the PC and DC...

Страница 23: ...tion Connect the other end of the cable to the DataPort on the correspond ing channel s DCA amplifier DATAPORT CONNECTION Use QSC DataPort cables Contact QSC s Techni cal Services Group if you would l...

Страница 24: ...h the processor manufacturer We recommended that you purchase a standard 25 pin cable from any of the well known cinema industry cable suppliers CINEMA PROCESSOR CONNECTION INSTALLATION Connections Ci...

Страница 25: ...oring available for the sub channel signal if this connection is used POWERED SUBWOOFER CONNECTION DCM 1 Terminals DCM 2 and 3 Terminals DCM 1 Terminals DCM 2 and 3 Terminals Output Level Impedance 11...

Страница 26: ...the amplifiers INSTALLATION Connections Surround Insert SURROUND INSERT CONNECTION TO SURROUND EX DECODER Pinout Configuration typical 9 pin SubD female on DCM end to loose wires attaching to surround...

Страница 27: ...need to make level adjustments INSTALLATION System Calibration SYSTEM CALIBRATION When installing a typical cinema sound system most of the calibration involves the Cinema Processor Refer to the user...

Страница 28: ...ic EQ screen EQ and Horn EQ driver and channel delay polarity and gain adjustments which can be used as additional compensation for speaker and installation characteristics Driver delay settings compe...

Страница 29: ...t to a useful level not fully counterclockwise Verify the desired active monitor source is selected by pressing the AMPS PROC selector button and observing the illuminated LEDs beneath channels select...

Страница 30: ...io is present If it is you know that the cables amplifier and speaker for the center channel are okay If you switch this back and still have no sound check the DCM configuration file for proper signal...

Страница 31: ...ections from the DCM to the center channel amplifier Verify the Cinema Processor and center channel amplifier are ON and functioning Verify the center channel amplifier s Gain controls are set to a us...

Страница 32: ...rsion 24 bit delta sigma 128x oversampled Filter Topology 24 bit digital IIR Subwoofer Output Adjustment 3 to 18 dB in 0 1 dB steps Dynamic Range 99 dB THD N at 12 dBu Input Level 0 02 20 hertz to 20...

Страница 33: ...VAC 260 VAC 50 60 Hz Fuse Littlefuse 218 001 or Bussman S5504 1A 250 Volt 1 Amp Safety Agency Approvals UL 6500 CSA EMC Approvals FCC Class A Connectors AC Power IEC style detachable cord receptacle R...

Страница 34: ...does not extend to any product which has been subjected to misuse neglect accident improper installation or where the date code has been removed or defaced QSC shall not be liable for incidental and o...

Страница 35: ...35 This page intentionally left blank...

Страница 36: ...36 QSC Audio Products Inc 1675 MacArthur Boulevard Costa Mesa California 92626 USA QSC and the QSC logo are registered with the U S Patent and Trademark Office 2002 QSC Audio Products Inc...